Concept

Tolerance — where it appears

The largest difference a specification will accept, stated as one number and meaning something different everywhere in the space. Stated as a single number it is a sphere in a space where the eye's own discrimination is an ellipsoid, so it is generous in some directions and strict in others.

Named by 64 essays across 9 fields — each of them below, with the objects they name alongside it.

Three colour-difference formulae, disagreeing. ΔE76, ΔE94 and ΔE2000 for the same 9 pairs of colours. The largest disagreement between ΔE76 and ΔE2000 here is 26.6 units — larger than the threshold usually quoted for a just-noticeable difference, so the choice of formula can decide whether two colours count as matching.

How far apart are two colours

ΔE is meant to be a distance with the property that the same number means the same perceived difference everywhere. Three successive formulae have tried, they disagree with each other by more than a just-noticeable difference, and the disagreement decides real matching questions.

difference · Metric
MacAdam's discrimination ellipses, drawn 10 times actual size. Twenty-five ellipses of colours indistinguishable from their centres. They are drawn at 10× because at true scale most are thinner than a line. Their areas vary by a factor of 74, which is the whole result: a step of the same size in xy means very different things in different places.

MacAdam measured it

In a perceptually uniform space the just-noticeable-difference contours would be circles of equal size. MacAdam's ellipses are neither, by a factor of eighty — and transforming them into each candidate space settles which spaces improved matters and by how much.

difference · Metric
Threshold and suprathreshold contours, normalised to the same size. At five of MacAdam's centres: the measured just-noticeable-difference ellipse in grey and the ΔE2000 = 1 contour in gold, each scaled to the same mean radius so that only shape and orientation are being compared. A scale change preserves orientation exactly, so any rotation between the pair settles the question. They differ by 24° on average and by 70° at worst, and the ratio between their sizes varies 4.8-fold across the diagram — so no single factor turns one into the other.

A threshold is not a unit

MacAdam measured the smallest difference anyone could detect. ΔE2000 was fitted to how far apart plainly different colours look. The two are quoted interchangeably, and the contours they produce are not even the same shape.

difference · Metric
A box tolerance and a ΔE tolerance around the same colour. A slice through CIELAB at L* 50, with the ΔE2000 = 1 contour traced point by point and a ±1 component box drawn over it. The contour is 2.1 times longer in one direction than the other, and the box is square. Of every sample either rule accepts, the two disagree about 74% — accepted by one specification and rejected by the other, on the same measurement.

A tolerance is a shape

A total colour difference below one, or every component within one — the two sound like the same requirement stated twice. They are different shapes, they disagree about most of what either accepts, and which one a supplier is held to is worth money.

difference · Metric
The 1976 uniform chromaticity diagram, with the unreachable region marked. The u′v′ diagram: the same spectral locus and the same sRGB primaries as the 1931 picture, projectively transformed. Straight lines stay straight, so mixtures and the gamut triangle survive; what changes is the distribution of area, and the green region that dominates the 1931 diagram is much reduced. 8% of the cells sampled inside the locus are reachable at Y = 0.55; the rest are hatched.

The diagram was replaced in 1976

The CIE knew the 1931 diagram was badly distorted and published a better one. Half a century later almost every chromaticity plot in print is still the old one, and both are still printed filled edge to edge with colours no display can show.

matching · Gamut
A 20 nm bandpass, and what it does to the sample. The true reflectance, the same reflectance as a 20 nm instrument reporting every 20 nm returns it, and the slit function responsible, drawn at its own scale around 550 nm. The reconstruction is what every calculation downstream will use, and it differs from the truth by ΔE 2.97 under D65. Nothing in the file the instrument writes marks which values were measured and which were interpolated.

What the instrument reports

A spectrophotometer sees a sample through a slit of finite width, at a finite number of wavelengths. What it writes down is the truth convolved with its own bandpass, and nothing in the file says which values were measured and which were invented.

matching · Gamut
Distinguishable colours in sRGB, counted under two difference formulae. The gamut volume divided by the volume of a ΔE = 1 ellipsoid, integrated over the solid because that ellipsoid changes size and orientation from place to place. Under the 1976 formula the answer is 195,720; under ΔE2000 it is 41,819 — 4.68 times fewer, from the same solid and the same lattice. Both assume perfect packing, which nothing achieves, so each is an upper bound rather than a count of anything. The gap between them is the result: "how many colours are there" is a question about a metric before it is a question about vision.

How many colours are there

Sixteen point seven million counts code values in a file format. Ten million distinguishable colours is a volume divided by the size of a just-noticeable difference — and the two difference formulae this site implements disagree about that size by a factor of nearly five.

difference · Metric
The ΔE = 1 contour at points across the L* = 55 plane, magnified 14×. Each closed curve is the set of colours exactly one unit of difference from the dot at its centre, traced by bisection along 30 directions and drawn 14 times life size. Under ΔE2000 the contours run from 0.68 to 5.07 CIELAB units across this slice — a ratio of 7.44 — and they are not circles and not aligned with each other. A formula whose contours were circles of one radius everywhere would be claiming that CIELAB is uniform, which is what the 1976 formula claims and what the measurements refuse.

Where the formula is not smooth

A colour difference formula is a distance, and a distance ought to vary gently. CIEDE2000's does not everywhere — it carries a hue-rotation term with a hard edge in it, and the discontinuity sits where a great many industrial samples live.

difference · Metric
A metameric match that a corner breaks. Two reflectances with identical XYZ under D65 — metamers, matching to ΔE00 = 5.4e-14, which is the numerical floor rather than an approximation. On a flat wall the light meets one of them once and the two patches are the same colour. In a corner, a fraction 0.200 of what leaves the surface returns to it, so part of what reaches the eye carries ρ twice — and the match fails by ΔE00 = 1.53. A metameric match is an identity between three integrals that are linear in ρ, and there is nothing linear left after a second bounce. The geometry, not the light and not the paint, is what breaks it.

Two paints that stop matching

A metameric match is an identity between three integrals that are linear in reflectance. A second bounce carries reflectance squared, and no linear identity survives being squared — so two paints certified identical on a flat chart come apart in a corner, by an amount the geometry decides and the colorimetry cannot express.

scene · Scene
A glossy surface returns two spectra, and only one of them is the paint. The dichromatic reflection model, computed rather than assumed. Light that enters a dielectric binder, scatters off pigment and comes back carries the reflectance — the body component, ΔE00 = 33.7 from the lamp. Light reflected at the interface never entered, so it carries the lamp's spectrum with only Fresnel's slight dispersion on it: ΔE00 = 1.14. The interface term is computed from Fresnel's equations on a Cauchy index at 45°, so its near-neutrality is a result here rather than an assumption. This is why a highlight is the one region of a photograph that tells a white balancer what the light was, and why removing highlights removes the evidence.

Gloss changes the measurement

The same sample measured with the specular component included and excluded returns two different numbers, and both are correct answers to different questions. Colour is one of four appearance attributes and the only one most instruments report — so a specification that names a colour has silently named a geometry too, and usually does not say which.

scene · Scene
The solids, by volume. CIELAB volume, all measured by the same cell count with the same extrapolation, and quoted against sRGB because that is the comparison the estimator supports. The four-colour press reaches 49 per cent of the sRGB solid's volume — and contains colours sRGB does not, which is why "half the gamut" is the wrong summary of a ratio of one half.

The fourth ink is not for colour

Black is in every process set and it extends the gamut by more than a third — and at every lightness above about forty it extends the chroma boundary by exactly nothing. What it buys is depth at the bottom, a neutral that holds its hue when the press drifts, and a way to put a full-strength dark on a sheet that could not carry three inks' worth of it.

applied · Delivery
What separates the separations, and under which light. 11 separations of a single colour, differing only in how much of it is carried by black rather than by the three chromatic inks. Under D50 they agree to ΔE00 = 0.00 — the solver was asked for that and delivered it. Under illuminant A they spread to 6.75. They are metamers of one another, and the whole family is invisible to any instrument reading a single illuminant.

The lamp in the shop decides

Two packages printed to the same specification, verified under the same standard illuminant and passed, can differ by nearly seven colour differences on a shelf under a tungsten lamp. Nothing went wrong at either press. The specification named one light, the separations that satisfy it are metamers of one another, and the shop chose the second light.

applied · Delivery
A named ink, and the closest four-colour build of it. The ink is one pigment chosen for its own spectrum; the four-colour build is three chosen for everything. The four-colour build reaches it to ΔE00 = 0.37 under D50 and drifts to 4.46 under a tungsten lamp, because the match is metameric — the two curves cross 4 times rather than coinciding anywhere.

A brand colour is an ink

A named colour is a jar of pigment with a spectrum, and a four-colour build of it is three inks arranged to integrate to the same three numbers. Of 156 constructed single-pigment inks, 15 can be matched at all — and those fifteen drift by a median of 3.8 colour differences under a tungsten lamp, because the match was never a match.

applied · Delivery
The worst triple found, under ΔE2000. Three colours, plotted on the a–b plane of CIELAB. Going from a to c directly is 123.645; going via b is 60.528, which is 51.0 per cent shorter. A distance cannot behave that way, and this one is the formula every colour tolerance in industry is written in. The colours are far apart, which is where the violation is largest; the same search confined to tolerance scale finds a smaller one that has not gone away.

A difference is not a distance

Two earlier essays here said that CIEDE2000 violates the triangle inequality and left it at that. Searching for the violation finds a detour half the length of the direct route, a smaller one inside a five-unit ball, and a second defect nobody mentions — ΔE94 is not even symmetric.

difference · Metric
A chromatic line screen at 10.0 cycles per degree. The upper strip is the pattern as delivered and the lower one is the same pattern after each opponent channel has been low-passed at its own cutoff. Against a flat field of the same mean, the delivered pattern differs by up to ΔE00 14.22 and the filtered one by 7.77 — a ratio of 1.8. Every number quoted elsewhere for a difference of this kind is the first one.

A difference has no size

A colour difference formula answers a question about two large patches seen side by side. Applied to a pattern, it reports fourteen units where the eye is left with less than one — and the ratio depends on nothing but how finely the difference is spread.

difference · Metric
Cone density, out from the centre of gaze. Quoted landmarks with logarithmic interpolation between them: 199,000 cones per square millimetre at the fovea, 9,500 at ten degrees — a factor of 21. The shaded bands are the two standard observers' fields. The 2° observer averages over a region whose density falls by 3.3× between its centre and its edge and the 10° observer by 12.4×, which is what "a 10° field" contains and is why the two sets of matching functions are different shapes rather than the same shape scaled.

Colour stops at the edge of sight

Cone density falls twenty-one-fold between the centre of gaze and ten degrees out, and the three channels give out at three different rates — so a colour difference in the periphery does not merely shrink, it turns. At the exact point of fixation there are no short-wavelength cones at all.

eye · Cones
Colour temperature, and the number nobody quotes beside it. The Planckian locus in the 1960 UCS diagram — the only diagram on which correlated colour temperature is well defined — with four sources and the perpendicular from each to its nearest point. The temperature is where the foot of the perpendicular lands; Duv is how long the perpendicular is. halophosphate sits 0.0246 off the locus at 4513 K, which is a visible green cast that its colour temperature does not mention.

White is a region

A lamp is not sold as a chromaticity. It is sold as 4000 K, and what that means is that its chromaticity fell inside a quadrangle — which two lamps can occupy at opposite corners, eleven ΔE00 apart. In a room with either of them, the same twelve surfaces differ by one unit.

light · Light
How often two colour-difference formulae disagree about which pair is worse. Pairs of colours sampled in CIELAB, compared two at a time. A rank inversion is a case where one formula calls pair A worse and the other calls pair B worse; no monotone rescaling of either can remove one. The left bar of each group is the rate over the whole space and the right bar is the rate among pairs sitting near a tolerance of ΔE 1, where the decision is actually made — and it is between 35 and 44 per cent, against a coin flip at fifty.

Which of two is worse

Two colour-difference formulae disagree about which of two pairs is the larger difference in thirteen per cent of comparisons overall — and in forty-three per cent of comparisons among pairs sitting near a tolerance of one unit, which is where every acceptance decision is actually made.

difference · Metric
One colour difference, at four places in the visual field. The same pair of colours — ΔE00 22.0 at the fovea — with each of its three components divided by that channel's own threshold scaling at the stated eccentricity. What is left at 20° is 4.4, and its hue has turned by 26 degrees, because the red–green part is divided by more than the blue–yellow part. The swatches are the predicted colours, drawn where a reader will look straight at them; the figure states a prediction it cannot stage.

A difference has no place

A colour difference formula answers a question about two patches somebody is looking straight at. Move the same pair ten degrees into the periphery and a third of it is left — and it has turned twenty-four degrees of hue, because the three channels give out at three different rates.

difference · Metric
How large a step changes the name, across the ab plane at L* 60. At each point, the smallest ΔE00 step in any direction after which the probability of two people using the same word has halved. It runs from 4.8 to 33.8 units across this one plane, in eight quantised levels: the palest cells are where a name is finest — a short step changes it — and the strongest are the middles of large territories, where a colour can move twenty units and keep its word. The ragged edge is the sRGB boundary at this lightness rather than a property of the vocabulary. The boundary softness is a stated parameter of the model, and the map barely moves when it is changed fourfold, because what sets this quantity is how far apart the centroids are.

A name is not a threshold

Two colours have to move about ten times a just-noticeable difference apart before people stop calling them the same thing, and how far varies threefold across one plane of the space. A tolerance and a word are answering different questions, and nothing in colorimetry converts between them.

brain · Appearance
One tolerance decision, at four spectral distances. Every column is a pair of samples ΔE00 1.0 apart for the observer a colorimeter models — solved to that value by bisection, so the instrument would report the same number for all four. What differs is how far apart the two spectra are, which is achieved by adding a metameric black the reference observer cannot see. The bands are what two hundred people report: from 1.13 at the ninety-fifth percentile when the spectra are the same shape to 2.32 when they are not, and the worst case reaches 3.7. No specification records the quantity on the horizontal axis.

A tolerance is a probability

A colorimeter reports one number and a specification compares it with another, and both are computed for an observer who does not exist. Handed to two hundred people, the same pair at ΔE00 1.0 is read from 0.8 to 3.7 — and which of those two ranges applies depends on something no specification records.

difference · Metric
The three constants a specification does not quote. ΔE2000 is defined with three parametric factors in it — kL, kC and kH — which the CIE leaves to the industry using the formula rather than fixing. Graphic arts uses ones throughout; the textile standard weighs lightness at half, which is kL = 2. Applied to 4000 pairs at a tolerance of 1, the two settings accept 46 and 75 per cent, and 29 per cent of pairs change verdict — a larger disagreement than any between the formulae themselves. The reference conditions the ones assume are diffuse illumination at 1000 lux, a mid-grey surround, samples abutting, subtending over four degrees, differing by under five units, with no visible texture.

Three constants nobody quotes

CIEDE2000 is defined with three parametric factors in it, the CIE leaves them to the industry using the formula, and the two settings in ordinary use differ by a factor of two in one of them. Twenty-nine per cent of acceptance decisions change between the two — a larger disagreement than any between the formulae themselves.

difference · Metric
Which of two reproductions is better depends on which statistic is asked. A specification for a proof or a print run is written against a set and has to reduce the set to one number. Here are two candidates: the one with the lower mean has the higher ninety-fifth percentile, so the mean prefers A and the tail prefers B. Across 2000 pairs of candidates generated the same way, the two statistics disagree about the winner 30 per cent of the time. Both numbers are honest; only one of them is what somebody notices.

A mean is not a difference

A specification for a proof, a profile or a print run is written against a set of colours and has to reduce that set to one number. The mean and the ninety-fifth percentile disagree about which of two reproductions is better in thirty per cent of cases, and both numbers are honest.

difference · Metric
One tolerance decision, about pairs that agree less and less about the spectrum. Every point is a pair of samples that the reference observer reports as exactly ΔE00 1.0 apart — the same number, the same decision, the same line in the same specification. Along the axis is how far apart their two reflectances are. Up the side is the 95th percentile of what two hundred other eyes report. It runs from 1.13 to 2.32. The document records the horizontal line and not the axis it is plotted against.

A tolerance needs a second number

Two samples one colour difference apart can be read almost identically by everybody or two units apart by the worst-off twentieth, and which of those it is depends on how far apart their spectra are — a quantity every spectrophotometer has already measured and none of them prints. Adding it as a second field predicts the population three times better, and at the tolerances where it matters it is right about a third of the decisions the difference alone gets wrong.

difference · Metric
A viewing booth is a lamp, and a lamp has an angle. The same sample at five positions across a booth's plane, with the lamp 55 centimetres above it. The curve is how far each position is from the middle, in the units the judgement is made in. It reaches ΔE00 2.40 against a tolerance of 1, while the illuminance uniformity — the quantity the standard actually bounds — never falls below 73 per cent and stays comfortably inside it. The flat trace is the same booth with a source whose converter is the same thickness in every direction: ΔE00 0e+0, exactly, by construction.

The booth is a luminaire

A standard viewing booth is specified by its light's chromaticity, its rendering and the uniformity of its illuminance across the sample plane. Illuminance is a photometric integral, so two positions can be inside the uniformity tolerance and lit by two different spectra — and a sample at the far corner of a compliant booth is ΔE00 2.4 from one in the middle, against a tolerance of one.

applied · Delivery
A tolerance of one unit, re-measured under every light in the census. Every one of the 23 pairs behind this figure is at exactly ΔE00 1.000 under D65 by construction. Each bar is what those same pairs measure under another light, after the observer has adapted to it: the line is the median and the bar spans the pairs. A tolerance is written as a property of a pair and it is not one — the light multiplies both members, and the difference between two products is not the product of the difference. The widest row is a lens at twenty against a lens at seventy, spanning 0.81 to 1.57.

One unit in another room

Twenty-three pairs built at exactly ΔE00 1.000 under D65, re-measured under every change of light this site models with the observer adapted to each, come out anywhere between 0.64 and 1.57. A tolerance is written as a property of a pair and it is a property of a pair and a room.

difference · Metric
The same twenty-four samples, measured two standard ways. How far apart a 45°/0° instrument and a sphere with its gloss port closed are, on samples running from three per cent reflectance to seventy. The whole of the difference is the interface reflection — four per cent of the light, returned without ever meeting a pigment, thrown away by one geometry and collected by the other. It is the same four points in every row, which is why the disagreement is a property of how dark the sample is rather than of what colour it is: ΔE00 8.7 on the darkest samples against 1.93 on the lightest.

An instrument has a geometry

Every reflectance here arrives through a model with a bandpass, a sampling interval and no position at all. Real instruments say where they were standing, and the two standard answers disagree by ΔE00 8.35 on a dark gloss sample — a difference that adds rather than multiplies, and that no adaptation removes.

matching · Gamut
The best possible 3×3, and the patches it makes worse. Each row is one patch printed on a brightened sheet, measured under both conditions. The pale bar is how far apart the two measurements are; the dark bar is what is left after the best least-squares 3×3 over the whole set has been applied. It leaves 23 per cent of the mean, and — the part a mean hides — it makes 4 patches worse than doing nothing. The solids are the ones it damages: the ink blocks the ultraviolet, so a solid barely disagrees between the two conditions and the correction has no business touching it. A matrix has no way to apply itself only where the paper is showing.

A tolerance cannot cross a condition

If two measurement conditions disagree by seven units, the obvious repair is a correction matrix fitted between them. The best least-squares 3×3 over seventeen printed patches leaves 23 per cent of the disagreement and makes five patches worse than doing nothing — because the term it is trying to remove is proportional to how much paper is showing, and no linear map on three numbers can express that.

difference · Metric
Which of a camera's three dyes each direction moves. A grid with one column per direction — stiffest on the left, flattest on the right — and one row per parameter of a camera's three dyes. Each cell's bar length is that parameter's share of that direction, so a column with one long bar is a direction that moves one thing. The stiffest column is dominated by blue centre, at a weight of 0.96. The flattest column is spread across blue width, red width, green width — a combination rather than any single number, which is why a specification listing one tolerance per parameter cannot express it.

Where a camera is blind to itself

A colour filter array is six numbers — three dye centres and three bandwidths — and how well the resulting sensor adapts is far more sensitive to some combinations than to others. The stiffest direction is almost entirely where the blue dye sits. The flattest is all three bandwidths at once, and the design can move twenty-five times further along it for the same cost.

imaging · Capture
A primary's tolerance is a shape, and part of it is unreachable. The CIE chromaticity diagram with the spectral locus drawn, and three closed regions marking where each primary of a display designed for its own inverse can sit while the adaptation cost stays within 1 per cent of its best. None of them is round: the widest runs 15.1 times further one way than another, so a single tolerance figure for a primary is the average of a shape the shape never takes. 47 of the 144 boundary directions leave the region a real primary can occupy, which is a second constraint the objective knows nothing about — the cost does not rise there, and the primary cannot go there.

A tolerance is a region

How far a display's red primary can move before its adaptation behaviour costs anything is not a distance. It is a closed region on the chromaticity diagram, fifteen times longer one way than another, and about half of it lies outside the area a real primary can occupy — where the objective does not rise and the primary cannot go.

applied · Delivery
A camera's dye widths are free under one requirement and not under another. Three panels, one per dye. In each, a pair of bars per requirement: how far that dye's centre wavelength and its bandwidth can move before the requirement gets five per cent worse. Under the adaptation objective — the one the previous round measured — every width has far more room than its centre, which is the finding that put a tolerance budget on the centres. Throughput and the colour matrix's noise gain, the two requirements that objective was said to be silent about, reach the edge of the search in every direction and hold nothing. What tightens the widths is the Luther residual, which was in the model already. The bottom pair in each panel is what survives all four.

The widths were free because nothing else was asked

A camera's three dye bandwidths carry almost all of the flattest direction of the adaptation objective, so that objective says a tolerance budget belongs on the centre wavelengths. The two requirements it was said to be silent about turn out not to bind either — and the one that does was in the model already.

imaging · Capture
What a camera's dye 1 is allowed to be, under four requirements. The plane a colour-filter dye is designed in: its centre wavelength across, its bandwidth up, both in nanometres, so the two axes are comparable and the shapes mean something. Four outlines, one per requirement, each the set of dyes within five per cent of the designed one on that requirement; the shaded region is where all four hold. Two of the four — throughput and the colour matrix's noise gain — reach the edge of the search in every direction and are invisible as boundaries. The intersection is ±6.8 nanometres of centre and ±13.3 of width, against the adaptation objective's own ±20.6 in width alone.

Two tolerances do not meet in a tolerance

A specification lists requirements separately and a manufacturer has to satisfy them together. Where two long thin regions cross at an angle, what is left is much smaller than either, its longest direction is neither of theirs, and no list of tolerances describes it.

imaging · Capture
What a display's red primary is allowed to be, under four requirements at once. A close view of the chromaticity plane around one designed primary, 0.101 units across. Four outlines: the set of positions the primary can take before each of four requirements gets one per cent worse — how well a gain in the display's own basis undoes a change of light, how much of the diagram the three primaries enclose, how many real surfaces fall inside them, and whether a light of that colour exists at all. The shaded region is where all four hold. It is 5% of the smallest outline's area, because the outlines are long and thin and cross at an angle rather than nesting. adaptation holds 42% of its boundary, gamut holds 10% of its boundary, realisable holds 48% of its boundary.

A primary is chosen for four things

A display's primaries have to adapt well, cover the diagram, hold the surfaces anybody photographs, and be colours a light can actually have. Drawing all four tolerance regions around one primary shows that no single requirement decides where it can go, and that one of the four never decides anything.

matching · Gamut
The same tolerance, in the two numbers somebody actually sets. The plane a maker of a single-peak emitter works in: peak wavelength across, full width at half maximum up. Each marker is a candidate emitter whose chromaticity falls inside the colorimetric tolerance drawn for this display's green primary. They occupy a narrow band — peaks from 528 to 535 nanometres, a span of 7, against widths from 25 to 45 — so a tolerance stated as a region in chromaticity becomes ±3.5 nanometres of peak and a great deal of latitude in width. 2.0% of the 2501 candidates land inside at all: most of a region drawn in chromaticity is a colour no single-peak emitter makes.

A tolerance in the wrong coordinates

A display primary's tolerance is written as a region in chromaticity, because that is where the colorimetry lives. Nobody has a knob for chromaticity. What a maker of an emitter sets is a peak wavelength and a bandwidth, and the map between the two is so anisotropic that on the red primary its condition number is over eleven thousand.

matching · Gamut
Where a delivered colour's error actually comes from. Three bars and two totals. The profile's interpolation between its nodes contributes 0.13 ΔE00; the rendering intent, at the colorimetric setting, moves nothing that was already printable and contributes 0.00; and looking at the result in a dim room rather than the booth it was proofed in contributes 4.30, which is 97 per cent of the total. The two totals are the three added — 4.43 — and combined in quadrature — 4.30. The gap between those two rules is 0.127, about the size of the entire profile stage, and no standard says which rule to use.

A delivery tolerance is three tolerances

A colour reaches a reader through a profile, a gamut mapping and a room, and each has a number somebody chose. Each has an essay of its own here, and none of those essays had put the three costs in one column. Put there, the stage nobody controls carries ninety-seven per cent of the total.

applied · Delivery
A published residual is a mean, and the worst object in the room costs twice it. Three bars for each of the 14 changes of light in the adaptation census, ordered by how uneven the change is across surfaces. The first bar is the published mean residual. The second is the worst single surface in the audit's published test set. The third is the worst surface anywhere in the region that set is drawn from, found by search rather than by reading a maximum off a lattice. The mean-to-worst ratio runs from 1.90 to 4.02 and averages 2.43, so every published adaptation number has a worst case about twice it that no essay had ever quoted. The gap between the second and third bars is the other finding: a maximum over 125 sampled points understates the region's own maximum by up to 34 per cent.

A mean is not a worst case

Every adaptation number this collection publishes is an average over objects, and the reader asking whether adaptation will fail them is asking about the object it fails on. That object costs between 1.9 and 4.0 times the published figure, and how uneven a change of light is across objects turns out to be a property of the change rather than a constant.

limits · Limits
A gradient of one hue, mapped into a press's gamut 3 ways. Chroma asked for along the bottom, chroma delivered up the side, for a ramp at lightness 55 and hue angle 25°. A colorimetric intent follows the diagonal until the press runs out and is flat afterwards — the flat part is a gradient arriving as a single colour. The perceptual intent is under the diagonal from the start, which is the price of never going flat.

A budget drawn through one hue

The three-stage error budget this collection publishes for a colour-management chain is computed over twenty-four colours of a single hue at a single lightness. The quantity that actually varies with hue — how many distinguishable colours a rendering intent destroys — runs from nothing at all to more than a third, and the hue the budget uses is near the bottom of that range.

applied · Delivery
Pairs built to sit exactly on a ΔE2000 tolerance, read in every other unit. Twenty-four pairs of surfaces, each constructed by walking one member along a fixed direction until the difference is exactly 1.0 ΔE2000 under D65. The bar spans what those same pairs read in each unit, after calibration, with the tick at the mean. ΔE2000's own row is a point at 1.0 by construction. Every other unit spreads them: ΔE*uv reads them from 0.69 to 1.75, so a contract written at "one unit" accepts and rejects a different set of deliveries depending on which unit it means. CAM16-UCS rejects all twenty-four: it reads the closest of them at 1.43.

A tolerance is a boundary through pairs

Twenty-four pairs of surfaces built to sit exactly on a ΔE2000 tolerance of one read from 0.69 to 1.93 in the other five units. A contract quoting "one unit" without naming the formula does not become slightly wrong in another; it accepts and rejects a different set of deliveries, and in one case rejects every single one.

applied · Delivery
Four departures from the model equation, each at an ordinary strength. What each of the four assumptions inside a colour integral costs, in ΔE₀₀, on a stated sample under a stated light. The wavelength index is a coated printing paper measured with and without the ultraviolet of D50; the range is the same paper integrated from 300 nanometres and from 380; the place index is a pigmented plastic through a four-millimetre radius; the direction index is an eggshell paint beside a window. The spread is a factor of 7.0. This is a ranking of four examples rather than of four departures — each of them can be made larger by choosing a more extreme sample, and the marble in the same collection of materials reaches 12.7 on the index that comes third here.

Which index to buy an instrument for

Four departures from the colour integral, ranked by what they cost and by what it would take to remove each one. The ranking by cost and the ranking by price are almost exactly reversed — the two largest are removed by specifying a lamp and by widening a table, and the two that need new hardware are the two smallest.

applied · Delivery
An aperture and a gloss lobe, apart and together. Six materials, each measured through a four-millimetre radius and each given a gloss lobe, alone and at the same time. The pale bar is what the two cost added together as if they were independent; the dark one is what they cost when both are present. Every material comes out below the sum, by between 0.8 and 3.6 ΔE₀₀. The two departures partly cancel: the aperture removes light that went into the material and came back out too far away, and the interface returns light that never went in at all. Measuring either one alone therefore overstates what both together do, which is the opposite of the way interacting errors are usually assumed to behave.

Two departures that partly cancel

A glossy translucent sample has two of this round's four departures at once, and the expectation was that they would compound. They do the opposite. An aperture takes light away that went into the material and came back too far out; an interface returns light that never went in at all — so measuring either alone overstates what both together do, on every material tested.

difference · Metric
Four departures from the model equation, each at an ordinary strength. What each of the four assumptions inside a colour integral costs, in ΔE₀₀, on a stated sample under a stated light. The wavelength index is a coated printing paper measured with and without the ultraviolet of D50; the range is the same paper integrated from 300 nanometres and from 380; the place index is a pigmented plastic through a four-millimetre radius; the direction index is an eggshell paint beside a window. The spread is a factor of 7.0. This is a ranking of four examples rather than of four departures — each of them can be made larger by choosing a more extreme sample, and the marble in the same collection of materials reaches 12.7 on the index that comes third here.

The departures are larger than the tolerance

A delivery tolerance is written around one ΔE₀₀ and every one of this round's four departures is above it on ordinary material. A specification that names an illuminant, an observer and a tolerance, and does not name a measurement condition, an aperture and a field, has written a number that two honest laboratories can miss each other on by more than the number itself.

difference · Metric
Each departure over forty-two surfaces rather than one. The same six departures measured over a family of forty-two analytic reflectances — an absorption band of stated centre, width and depth — with the smallest, the median, the ninety-fifth percentile and the largest marked. Every one of them spans more than a factor of three, and the ranking between them is not stable across the family: what decides a departure's size is which sample it is asked about, because a departure is a pairing and the sample is one of the two factors. Quoting any single number for what an observer's age is worth is quoting a choice of example.

A tolerance with an observer in it

A delivery tolerance is written in ΔE₀₀ against the 1931 observer, and six departures of that observer combine to about three of the same units on an ordinary saturated sample. A one-unit tolerance is being asked to contain a three-unit uncertainty that nothing in its budget mentions.

difference · Metric
Each departure over forty-two surfaces rather than one. The same six departures measured over a family of forty-two analytic reflectances — an absorption band of stated centre, width and depth — with the smallest, the median, the ninety-fifth percentile and the largest marked. Every one of them spans more than a factor of three, and the ranking between them is not stable across the family: what decides a departure's size is which sample it is asked about, because a departure is a pairing and the sample is one of the two factors. Quoting any single number for what an observer's age is worth is quoting a choice of example.

A brand colour for a population

A brand colour is chosen once, specified in a number, and seen by everybody. The observer audit says two candidate colours with identical specifications can carry observer spreads differing by an order of magnitude, and that the spread is computable from an ink's spectrum at the moment the ink is chosen.

applied · Delivery
What one tolerance accepts, around four colours. The surface in tristimulus values that ΔE₀₀ 1.0 draws around four colours, each outline scaled to its own size so the shapes can be compared. The volumes they enclose differ by a factor of 1.0e+5 across the sRGB cube, and the longest axis of one shell is between 3.3 and 29.9 times its shortest. A tolerance is written as one number and is a different set of samples at every colour it is applied to.

What one number accepts

A delivery tolerance is written as a single colour difference and it acts on three tristimulus values, so what it actually accepts is a closed surface. Measured over sixty-four colours in the sRGB cube, the volume inside that surface varies by a factor of a hundred thousand and its longest axis is between three and thirty times its shortest. The same contract, applied to a dark colour and a light one, is two different requirements.

matching · Gamut
The model's hue scale, and the four numbers it is built from. Hue quadrature against hue angle. The four anchors are the unique hues, each with its own weight, and between them the scale is a hyperbolic interpolation rather than a straight line. The quadrant from blue back to red spans 143 degrees of hue angle for its hundred units of quadrature, against 70 for red to yellow.

The hue scale has four corners

CIECAM16 reports hue twice — as an angle in its own opponent plane, and as a quadrature interpolated through four unique hues with four fitted weights. The second is the one hue tolerances and hue-preserving mappings are written in, and it is piecewise — its slope jumps at each of the four anchors, by a factor of 1.74 at green and by 0.41 at blue, and it runs 4.1 times faster near yellow than near blue.

brain · Appearance
What a stated lightness pins down, and where. A lightness quoted to 0.05 of a unit, inverted, and the luminance it fixes. Read as a fraction of the colour's own luminance the requirement is 0.90 per cent at J 10 and 0.097 at J 95, a factor of 9.3. Read in absolute luminance it is the other way round, by a factor of 6.5. Both readings are true and they answer different questions.

A stated lightness is two requirements

A specification quotes an appearance to a stated precision — a lightness to a tenth of a unit, say — and the same precision everywhere. Inverted, a twentieth of a unit of lightness fixes the luminance to nine tenths of one per cent at the bottom of the scale and to a tenth of one per cent at the top, a factor of 9.3. Read in absolute luminance it is the other way round by a factor of 6.5, and both readings are true.

brain · Appearance
Which way each tolerance is tightest, colour by colour. Sixty-four colours on a lattice through the sRGB cube, with lightness across the bottom. For each, the tolerance ΔE₀₀ 1 is pulled back into tristimulus values and its shortest and longest axes are found. The filled points are the angle between each colour's shortest axis and the direction common to all of them: a median of 15 degrees, ninety per cent within 32. The open points are the same for the longest axis, at 23. The common short axis is 3.1 degrees from X up and Y down, which is the direction of a*.

A tolerance has a grain

A colour tolerance pulled back into tristimulus values is a long thin shape, and across the whole sRGB cube its shortest axis points the same way, fifteen degrees off at the median — the direction in which X rises as Y falls, which is the direction of a*. So what one colour difference allows depends on which way a delivery drifts. An instrument's X filter may age 1.4 per cent before the tolerance is used up, its Z filter 5.1, and the light on the sample 9.3.

matching · Gamut
What a small neutral deviation costs as the grey darkens, in two lightness scales. The price of a fixed fraction of deviation on a neutral — how much lightness it is worth per unit of luminance — from L 40 down to L 0.25, both axes logarithmic. CIELAB's L is a straight line below L 8 and its price there is exactly flat. The appearance model's J′ has no straight piece: its price keeps rising, by a factor of 5.0 across the same range, as the luminance to the power -0.442 — the derived exponent is -0.441 in an average surround.

The appearance model has no straight piece

CIELAB's lightness is a straight line below L* 8, so a deviation near black has a fixed price and a black has a floor under it. CIECAM16 has no such piece. Its lightness near zero goes as the luminance to a power set by the room, the price of a deviation rises without limit as the black deepens — as Y to the power −0.44 in a lit room and −0.58 in a dark one — and on a projected black a lightness unit in the model allows under half the luminance change a unit of L* allows.

matching · Gamut
A soft proof exact for one observer, and three proofs tuned for readers. For each display, the median over printed patches of the 95th percentile reader's mismatch between screen and print, for four ways of choosing the display's three drive levels: exact for the reference observer; least squares over a population of a hundred; tuned on that population's 95th percentile; and tuned on the two hundred readers it is scored on, which no workflow could do. On a wide-gamut LCD the four give 4.57, 4.99, 4.74, 4.39, and the three tuned proofs cost the reference observer 0.70, 0.82, 0.69. On an OLED panel the four give 5.12, 5.72, 4.99, 4.86, and the three tuned proofs cost the reference observer 1.35, 0.95, 0.67. On a laser projector the four give 7.54, 7.00, 6.81, 6.50, and the three tuned proofs cost the reference observer 1.88, 1.23, 1.14.

A proof cannot be tuned for readers who disagree

A soft proof matched exactly for the standard observer is five colour differences wrong for one reader in twenty. Giving up that exactness to tune the display's three drives for a population instead moves the ninety-fifth percentile reader by 4 to 14 per cent even when the tuning is done on the very readers it is scored against — because what readers see is mostly each other's disagreement, and three drives act on every reader at once.

applied · Delivery
Where a press's variation lies, and where the tolerance charges for it. Each printed patch's sheet-to-sheet variation under four stated mixes of press variation, split along the three axes of a one-unit ΔE₀₀ tolerance at that patch, tightest first. The upper bar of each pair is the share of the variation along each axis and the lower the share of the price, averaged over 29 patches. For an even mix the tightest axis holds 1.5% of the variation and pays 29% of the price, and the loosest holds 83% and pays 36%. For inking alone the tightest axis holds 2.0% of the variation and pays 34% of the price, and the loosest holds 79% and pays 28%. For a gain-led press the tightest axis holds 1.8% of the variation and pays 29% of the price, and the loosest holds 83% and pays 39%. For a trap-led press the tightest axis holds 1.6% of the variation and pays 29% of the price, and the loosest holds 82% and pays 35%.

A press is charged for the direction it barely moves

A press run varies almost entirely along the direction a colour tolerance forgives. Split along the tolerance's own axes under four stated mixes of press variation, its tightest axis holds about one per cent of the sheet-to-sheet variation and pays a quarter to a third of the price — and on a blue overprint four fifths, for the balance between two inking units rather than the level of either.

matching · Gamut
The same pairs, held at one colour difference, read in a unit that knows the room. 23 pairs of reflectances built to sit at exactly ΔE₀₀ 1.000 under D65, read in CAM16-UCS as the adapting luminance runs from a third of a candela a square metre to ten thousand, in an average surround. ΔE₀₀ has no argument for the room, so in that formula every pair stays at 1.000 all the way across — the flat line. In the model's unit the same pairs rise from a median of 0.76 to 1.30, and they do not rise together: at the bright end they run from 1.11 to 1.65.

A tolerance has no light level

Twenty-three pairs built at exactly one colour difference stay at exactly one in every room, because the formula has no argument for the room. Read in the unit that does have one, the same pairs are 0.72 in a cinema, 1.04 in an office and 1.30 in direct sun — and inside any one room they spread by half again, so no single conversion between the two units exists at all.

difference · Metric
What is left of one colour difference when the two colours alternate. 23 pairs built at exactly ΔE₀₀ 1.000, alternated at a rate, with each part of the difference scaled by its own temporal channel and the formula then applied unchanged. At rest every pair is the flat line at one. By 7 hertz the median is 1.11 and the pairs run from 0.57 to 3.04 — a factor of 5.3 between pairs the formula calls identical. By sixty hertz the largest of them is 0.15.

A difference has no rate

A colour difference formula answers for two patches that are both there and stay. Alternate the same two colours and the difference is not scaled but taken apart: the colour half is gone by fifteen hertz and the lightness half is four times louder at eight, so twenty-three pairs the formula calls identical run over a factor of six at the rate the eye is best at, and are worth nothing at all above sixty.

difference · Metric
The metamerism index, computed three ways, as the reference match loosens. The special metamerism index of 6 metameric pairs under an incandescent test light, against how well each pair matches under the reference light. Uncorrected, the index absorbs the reference mismatch and rises from 2.86 to 3.76. Corrected multiplicatively it rises to 3.31 and additively to 3.87. All three are the same number when the pair matches exactly, which is the only case the definition covers.

The metamerism index has two corrections

The index for a metameric pair is defined for a pair that matches exactly under the reference light, and no real pair does. The standard's remedy is to correct the sample first, and it names two corrections — scale the tristimulus values, or add the difference. On six pairs matched to one colour difference, the two answers differ by a tenth to four tenths of an index unit; at two, by a whole one.

matching · Gamut
One grey scale, three backgrounds. CIECAM16's lightness against the luminance factor of a neutral sample, with only the background changed. A grey reflecting 19% reads 46.7 on a near-black background and 32.8 on a near-white one. The three curves are not three shapes: each is the same curve raised to a different power, because the background reaches lightness only through the exponent z, which runs 1.621 to 2.374 across the three.

A dark background moves every difference and no match

CIECAM16's background is one number, and it reaches lightness as one exponent. That is enough to change what a grey looks like and not enough to change which of two greys is lighter — so a match survives the background exactly, a corresponding colour is invariant to it, and a tolerance is not. The effect the background is usually invoked to explain is absent from the model entirely.

brain · Appearance
Every pair of departures, before adaptation and after it. The fifteen pairs of the six audited observer departures. Each row runs from the angle between that pair's two deviations with no adaptation to the angle with complete adaptation; an angle past ninety degrees is a pair pointing apart, which is where a pair can cost less together than the larger of the two costs alone. 3 pairs gain that behaviour as the eye adapts, 3 keep it, 5 lose it and 4 never have it. The pair followed here — the lens against the macular pigment — is in the smallest group that is not empty, and every result quoted from it generalises in the wrong direction.

Adaptation turns more pairs off than on

One pair of observer departures was followed across the degree of adaptation and found to cancel only in a bright enough room. The same calculation takes any two, and run over all fifteen pairs it says something the single pair does not: adaptation is a rotation rather than a mechanism for making departures oppose each other. Five pairs lose their cancellation as the eye adapts, three gain it, three keep it and four never have it — and the pair everybody quotes is one of the three it turns on.

difference · Metric
Six departures, and three ways of adding them up. The six audited observer departures on 120 smooth reflectances, across the dial. Summing them assumes they all point the same way and is an overestimate everywhere; taking the largest alone assumes only one matters and is an underestimate everywhere. Quadrature — the usual way of combining contributions taken to be independent — assumes they are mutually perpendicular, and the measured combination crosses it at a degree of 0.8618. Below that the departures are on balance pointing together and quadrature is too small; above it they are on balance pointing apart and quadrature is too large. It is exactly right in one room.

Quadrature is exact in one room

An observer allowance is built by adding the departures in quadrature, which assumes they are mutually perpendicular. Over fifteen pairs their angles run from 18 degrees to 179 and hardly any are perpendicular. Measured against the real combination, quadrature is too small in a cinema by eight per cent and too large under the sky by fourteen, crossing at an adapting luminance of 22 candelas a square metre — and on individual surfaces it is out by a third in both directions in every room.

difference · Metric
Where a surface's band sits decides the room it needs. Each of 168 surfaces at its own crossing — the degree of adaptation at which the part adaptation has yet to remove falls to the size of the part it will leave — against where that surface's absorption band sits. The line joins the median at each band centre and the rooms are marked across. A surface absorbing at 470 nm crosses at 0.883 and one absorbing at 670 nm at 0.972. Both of the filters this is about absorb in the blue, so a surface with a blue band is where the two differ in shape and has a large residual, while a surface with a red band is nearly invisible to both and its whole deviation is the shared yellowing of the observer's white.

The room a surface needs is written in its band

Whether two yellow filters cancel on a surface depends on the room, and each surface has its own crossing — the degree of adaptation at which the shared yellowing falls to the size of what is left underneath. Those crossings run from 0.68 to 0.99, and where a surface's absorption band sits accounts for almost all of the spread while how much light it returns accounts for almost none. The reds need a room brighter than a graphic-arts viewing booth, which is brighter than any room a sample is judged in.

difference · Metric
One instrument, one uncertainty, six places on the scale. What an absolute uncertainty of 0.001 in measured reflectance is worth in lightness, at six levels from a four-colour solid to the paper. Nothing about the instrument changes between the rows: what changes is the slope of the lightness function, which is a straight line of 903 units per unit of luminance factor below a luminance of 0.0089 and a cube root above it. At the solid the uncertainty is 0.903 lightness units and at the paper 0.043 — 21 times as much, for the same measurement.

The scale hangs from one measurement

Black point compensation is a straight line between two blacks, and the destination's is a measurement of one patch at the darkest place a spectrophotometer is ever asked to read. The lightness scale's slope is 903 units per unit of luminance factor there and 43 at the paper, so a thousandth of a reflectance is worth nine tenths of a lightness unit at the black and four hundredths at the white. That one number moves a mid grey by nearly a quarter of a delivery tolerance, and no specification names it.

applied · Delivery
How often the choice of correction changes a pair's grade. Eighteen metameric pairs walked to each of eleven reference mismatches, with the share whose index falls in a different band under the two corrections the standard allows. At an exact match the share is zero and must be: there is nothing for either correction to correct. It rises to 44 per cent at a reference mismatch of 2, which is the quality a dyehouse reaches rather than the quality a laboratory constructs. The banding is a five-step convention at 0.5, 1, 2 and 3, stated here rather than quoted, and how much the count depends on it is drawn separately.

The ambiguity is largest where the index is used

The metamerism index is defined for a pair that matches exactly under the reference light, no real pair does, and the two corrections the standard allows for the residual give different answers. Over eighteen pairs at eleven match qualities the gap is nearly a function of the mismatch alone — its middle half spans a factor of 1.4 at the mismatches a dyehouse reaches — so it could be tabulated. And it is largest exactly there: zero at a laboratory's match, and re-grading eight pairs in eighteen at a trade's.

matching · Gamut
Twenty-three pairs at one ΔE₀₀, read in two units that know the light level. Twenty-three pairs of surface colours, each exactly one ΔE₀₀ apart, on a display whose white runs from 1.5 to 10,000 cd/m² across, with a background at a fifth of the white. ΔE₀₀ has no argument for the light and stays at one. The median ΔEITP rises from 1.01 to 2.75 and flattens near the top, and the median CAM16-UCS distance from 0.76 to 1.20.

Two units with a light level disagree about lightness

ΔE₀₀ has no argument for how bright a display is. Two colour differences do: CAM16-UCS takes the room's adapting luminance, and ΔEITP — the difference defined for high-dynamic-range television — takes the stimulus's own absolute luminance. Twenty-three pairs at exactly one ΔE₀₀ grow in both as the display brightens, 2.1 times in ΔEITP and 1.5 in CAM16-UCS from a 5 to a 5,000 cd/m² white. But in ΔEITP the lightness part grows fastest, 2.7 times, and in CAM16-UCS it does not grow at all.

difference · Metric
How each unit balances lightness against chroma, as a display brightens. Twelve pairs built to differ in lightness alone and twelve built to differ in chroma alone, each at exactly one ΔE₀₀, read in both units at nine display levels. Up is the median lightness pair's reading divided by the median chroma pair's, so a falling curve means chroma differences becoming relatively more visible. Both fall. ΔEITP's median runs from 0.91 at a 1.5-candela white to 0.81 at 10,000, a fall of 11 per cent; CAM16-UCS's from 1.13 to 0.87, a fall of 23 per cent. Neither turns: both units say chroma differences gain on lightness differences as a display brightens, and CAM16-UCS says it twice as strongly.

The units part by hue, not by light level

Two colour differences with a light level in them were compared on a display running from 5 to 5,000 cd/m², and a prediction was drawn from how each divided a difference between lightness and chroma. Built into pairs that differ in lightness alone and in chroma alone, both units say the same thing about light level: as a display brightens, chroma differences gain on lightness differences — ΔEITP by a tenth, CAM16-UCS by a quarter. Where they part is hue. The appearance model moves every colour's balance by the same factor; ΔEITP moves the violets, reds and cyan-blues the other way, and at nine of twelve base colours the two units disagree about the direction.

difference · Metric
What a lit room takes, and where it takes it. On a display whose white is 1,000 cd/m², how much of the ΔEITP a one-unit lightness step is given survives a veiling luminance reflected off the screen, against where on the lightness scale the step sits. At L 2 — a deep shadow — one candela of reflected light removes 22 per cent of the difference and three candelas remove 46. At L 90 the same veils remove nothing measurable. The shadows the unit counts most are the ones a room removes first.

The shadows a unit counts are the ones a room removes

ΔEITP's growth with display brightness is largest in the dark greys, and dark greys are where a lit room's light reflected off the screen sits. One candela a square metre of veiling luminance removes 22 per cent of the difference the unit gives a step at the bottom of the scale on a 1,000-candela display and nothing measurable at the top. The same veil raises the growth the unit reports across display levels from a factor of six to a factor of seventeen, because it destroys a dim display's shadows first.

difference · Metric
How wrong a declared veil makes the unit, for four true veils. On a 100 cd/m² display, the worst error over grey steps from L 2 to L 90 — the size of the natural logarithm of the declared reading over the true one — against the veil declared, for rooms putting 0.1, 0.3, 1 and 3 cd/m² on the screen. Each curve reaches nought at its own true veil and rises on both sides. The flat stretch at the left is declaring almost nothing, which is declaring none: 0.22 for a true veil of 0.1, 0.54 for a true veil of 0.3, 1.14 for a true veil of 1, 1.89 for a true veil of 3.

A guessed veil halves the error

A colour difference that takes a display's absolute luminance leaves out the light a room reflects off the screen, and on an ordinary display in an ordinary room that makes it wrong about the darkest greys by a factor of three. Giving the unit the veil as a declared argument fixes that when the veil is known. The worry was that it never would be — that a guessed argument is no better than none. It is better: any declared veil up to about twice the true one beats declaring none, and one middling guess for every room halves the worst error. What a guess cannot do is reach ten per cent; that needs the veil known within a sixth, which is what a luminance meter aimed at a black screen gives.

difference · Metric
How much of a coated press is left at each margin inside its boundary. The share of a coated press's printable volume in CIELAB that lies at least a given distance inside its boundary, for margins from half a unit to 32. A margin of one unit keeps 88%, two keep 80%, four 66% and eight 45%. At every margin up to 30 what is left is a single connected piece; at 31 units, with 0.14% of the volume left, it first splits, into a core of 623 cells and 2 fragments of one or two cells — the deepest point is 32.7 units inside, so what splits is the last crumb of the core, not a waist.

A margin costs a press its corners

A gradient held inside a coated press by projection was predicted to tear if the press were first shrunk by a safety margin, at any pinch narrow enough for the shrinking to cut. The press has no such pinch: shrunk by any margin up to thirty CIELAB units it stays in one piece, and projected routes on it are neither trapped nor torn. What a margin costs is concentrated at the corners — the solid yellow moves nearly four times the margin to get inside, like the tip of a 31-degree spike.

matching · Gamut

Named alongside it

The objects these essays reach for when they reach for this one.

SpecificationΔEQuality controlCIEDE2000Colour differenceAcceptabilityCIELABJust-noticeable differenceLightnessMeasurement errorThresholdViewing condition

All concepts