Concept

Colour difference — where it appears

A single number standing for how far apart two colours look, computed from their coordinates in a stated space by a stated formula. Every such formula is a fit to threshold judgements, so a difference is a claim about a pair, an observer and an experiment rather than a distance.

Named by 57 essays across 8 fields — each of them below, with the objects they name alongside it.

How wrong the ellipses would have to be for a pair to change places. One bar per adjacent pair in the uniformity table: the relative error on each ellipse's own axes at which that pair changes places in one draw in twenty. No error on the data is quoted anywhere — the question is inverted, so what is reported is how large an error would have to be, and a reader with an opinion about MacAdam's experiment can compare it with their own number. The nearest pair goes at 0.171; 2 of the 7 pairs do not reverse under any error this search covers.

How wrong would the data have to be

Twenty-five ellipses measured on one observer in 1942 are the ruler every colour space here is judged against, and they have never been given an error. Rather than invent one, the question is turned round, and asks how large an error would have to be before the ranking changed.

difference · Metric
Twenty-five ellipses is a sample, and the score has an error bar. One row per colour space this collection ranks: the mean axis ratio its ellipses come out at, with the standard error of that mean over the twenty-five ellipses it was computed from. No literature is quoted — a mean of twenty-five numbers has a standard error those twenty-five numbers determine. The bars are far from equal: the best space carries ± 0.07 and the worst ± 1.56, because a space that makes the ellipses nearly circular makes all of them nearly circular and one that does not is dominated by whichever ellipse it handles worst.

Twenty-five is a sample of the diagram

A colour space's uniformity score is the mean of twenty-five numbers, and a mean of twenty-five numbers has a standard error those twenty-five numbers determine. Nothing has to be quoted to compute it, and three of the seven adjacent pairs in this collection's ranking survive it.

difference · Metric
Where a delivered colour's error actually comes from. Three bars and two totals. The profile's interpolation between its nodes contributes 0.13 ΔE00; the rendering intent, at the colorimetric setting, moves nothing that was already printable and contributes 0.00; and looking at the result in a dim room rather than the booth it was proofed in contributes 4.30, which is 97 per cent of the total. The two totals are the three added — 4.43 — and combined in quadrature — 4.30. The gap between those two rules is 0.127, about the size of the entire profile stage, and no standard says which rule to use.

A delivery tolerance is three tolerances

A colour reaches a reader through a profile, a gamut mapping and a room, and each has a number somebody chose. Each has an essay of its own here, and none of those essays had put the three costs in one column. Put there, the stage nobody controls carries ninety-seven per cent of the total.

applied · Delivery
What one change of light costs, surface by surface — daylight to tungsten. A rising curve of 125 points, one per surface in the test set, sorted from the surface this change of light costs least to the one it costs most, with the published mean drawn across it as a horizontal line. The published residual for daylight to tungsten is 1.635 ΔE₀₀. The curve runs from 4.4e-14 — 5 of the surfaces are flat greys, on which an adapted observer's gain is exactly right and the residual is exactly zero — to 3.058, which is 1.87 times the mean. The mean line crosses the curve about two thirds of the way along, so most surfaces cost less than the published number and a minority cost a great deal more. This is what a single published residual is a summary of.

A mean has a set under it

Every adaptation number this collection publishes is an average over a hundred and twenty-five surfaces that were written down once, in one file, with no argument for how many there should be or how saturated. The average runs from exactly zero to twice itself across them, and the set has never been varied.

scene · Scene
The error on a gap is not the two rows' errors added. Two bars for each of the 13 adjacent pairs in the census ranking. The upper, shorter bar is the standard error of the gap taken as a paired difference — the same 125 surfaces score both rows, so a surface that is awkward under one change of light is usually awkward under the other and the difference is quieter than either. The lower bar is the two rows' own errors added in quadrature, which is what comparing error bars by eye amounts to. Pairing is worth a factor of 1.78 on average and 3.36 on the pair it helps most, and it is the difference between 6 adjacencies unordered and 4. The gain is largest where the two rows are two daylights or two tungstens, because then the surfaces they find awkward are nearly the same surfaces.

The error on a gap is not the errors at its ends

Comparing two rows of a table by looking at whether their error bars overlap is the wrong comparison, and here it is wrong by a factor of up to 3.4. The same 125 surfaces score both rows, so the difference between them is quieter than either — and how much quieter is a measurement of how alike the two rows are.

difference · Metric
Which steps of the census ranking the test set actually resolves. A horizontal bar for each of the 13 adjacent pairs in the census's ranking, from the smallest mean residual to the largest. A bar's length is the gap between the two rows in ΔE₀₀; the whisker on its end is twice the standard error of that gap, computed as a paired difference because the same 125 surfaces score both rows. Where the whisker reaches back past zero the pair is not ordered by this test set, and 4 of the 13 are in that state — marked. The largest steps, at the two ends of the ranking, are twenty standard errors wide and are not in doubt at all. The smallest is four parts in ten thousand between two rows the table prints as different numbers.

Four steps the test set cannot order

The adaptation census prints fourteen numbers to four figures and its ranking is asked to say which lamps adaptation handles worst. Nine of its thirteen steps are established beyond any doubt the test set can raise; the other four are not, and three of them are consecutive — a tungsten lamp, a halogen lamp and a white LED are simply not ordered.

light · Light
How far each census row moves when the test set's own description does. A grid of bars, one row per change of light in the census and one bar in each row per number that describes the region the test surfaces are drawn from: how saturated they are, how bright, and how far the two modulations may go together. A bar's length is the elasticity — the proportional change in the published residual for a proportional change in that number. Saturation runs from 0.49 to 0.91 and brightness averages 0.104, so a test set's chroma range is nearly everything and its lightness range is nearly nothing. For scale, the largest elasticity found anywhere among this collection's five declared population widths is about a half — and those at least have declared ranges, while these three numbers have never been quoted with one.

Saturation is nearly everything

The set of test surfaces has three numbers describing it, and only one of them matters. How saturated the surfaces are carries an elasticity of about 0.7 on every result computed over them; how bright they are carries 0.10. A test chart's chroma range decides its answer and its lightness range does not.

difference · Metric
A published residual is a mean, and the worst object in the room costs twice it. Three bars for each of the 14 changes of light in the adaptation census, ordered by how uneven the change is across surfaces. The first bar is the published mean residual. The second is the worst single surface in the audit's published test set. The third is the worst surface anywhere in the region that set is drawn from, found by search rather than by reading a maximum off a lattice. The mean-to-worst ratio runs from 1.90 to 4.02 and averages 2.43, so every published adaptation number has a worst case about twice it that no essay had ever quoted. The gap between the second and third bars is the other finding: a maximum over 125 sampled points understates the region's own maximum by up to 34 per cent.

A mean is not a worst case

Every adaptation number this collection publishes is an average over objects, and the reader asking whether adaptation will fail them is asking about the object it fails on. That object costs between 1.9 and 4.0 times the published figure, and how uneven a change of light is across objects turns out to be a property of the change rather than a constant.

limits · Limits
How far each census row moves when the test set's own description does. A grid of bars, one row per change of light in the census and one bar in each row per number that describes the region the test surfaces are drawn from: how saturated they are, how bright, and how far the two modulations may go together. A bar's length is the elasticity — the proportional change in the published residual for a proportional change in that number. Saturation runs from 0.49 to 0.91 and brightness averages 0.104, so a test set's chroma range is nearly everything and its lightness range is nearly nothing. For scale, the largest elasticity found anywhere among this collection's five declared population widths is about a half — and those at least have declared ranges, while these three numbers have never been quoted with one.

A chart decides what a camera scores

A camera profile's reported error changes by a factor of five when the test chart's saturation changes, with the camera and its matrix untouched. The elasticity is 0.67 — the same figure, to two per cent, that an entirely unrelated measurement over an entirely unrelated set of surfaces gives.

imaging · Capture
A gradient of one hue, mapped into a press's gamut 3 ways. Chroma asked for along the bottom, chroma delivered up the side, for a ramp at lightness 55 and hue angle 25°. A colorimetric intent follows the diagonal until the press runs out and is flat afterwards — the flat part is a gradient arriving as a single colour. The perceptual intent is under the diagonal from the start, which is the price of never going flat.

A budget drawn through one hue

The three-stage error budget this collection publishes for a colour-management chain is computed over twenty-four colours of a single hue at a single lightness. The quantity that actually varies with hue — how many distinguishable colours a rendering intent destroys — runs from nothing at all to more than a third, and the hue the budget uses is near the bottom of that range.

applied · Delivery
Every census row under five constructions of the same test set. A slope chart with 5 columns — lattice, coarse, fine, uniform, natural — and one line per change of light in the census, each line joining that row's mean residual under each construction. Four of the five columns describe the same region of surfaces walked at different densities or against different measures; the last is the clamped, realistic family, which is not linear in its parameters and is therefore answering a slightly different question. The levels move: between the coarse and fine lattices every row shifts by seven to nine per cent, in the same direction, which is a common-mode factor no published residual here has ever carried. The order almost survives. Inside the region exactly one pair crosses, and it is the pair the standard error had already flagged; under the clamped set two more cross, including one the error separates by nearly nine standard errors. The crossing lines are drawn heavy.

What the audit still cannot reach

Two rounds have now swept every declared width in this collection and one of its structural choices. Three structural choices remain, none of them has a multiplier to sweep, and the reason each resists is different — which makes the list a description of where this kind of audit ends rather than a queue of work.

limits · Limits
What six of this collection's published numbers do when the unit changes. Six quantities, from six calculations that share nothing: a change of light after an observer has adapted, a camera profile's error, the gap between the two standard observers, a metameric pair under the lamp that breaks it, the same image on two papers, and an observer two seconds into a new room. Each is recomputed under all six units and every unit is calibrated onto ΔE2000's scale first, so the bar is not a change of units in the ordinary sense. The bar is the ratio of the largest reading to the smallest, and it runs from 1.71 to 2.30. Five of the six are printed in ΔE2000 by the essays that report them; the sixth is printed in CAM16-UCS, because the model it comes out of defines that unit.

A choice with no magnitude

An audit can multiply a width by 1.25 and report an elasticity. It cannot multiply CIEDE2000 by anything. Auditing a structural choice needs a different instrument, and building one shows that six published numbers in this collection each carry a factor of about two of unit-choice — after the change of scale has been taken out.

limits · Limits
The adaptation census in six units, calibrated onto one scale. Each line is one of the fourteen changes of light in the adaptation census, drawn across the six units the results could have been published in. Every unit is multiplied by the single factor that best carries it onto ΔE2000 over a reference sample of surface pairs, so the vertical axis means the same thing in every column and a sloping line is a disagreement rather than a change of scale. The levels move by up to a factor of two. More to the point, the lines cross: ΔEok puts 10 of the 91 pairs of rows in the other order, and CAM16-UCS, the only appearance unit here, puts the fewest — 2.

The census in six units

Recomputing every change of light in the adaptation census under six colour-difference formulae, with the scale factor divided out, leaves a table whose levels move by up to a factor of three point seven. The rows that move most are the mild ones, which is the opposite of what a reader would guess and is a property of where each formula was fitted.

light · Light
How far each unit is from being a rescaling of the one this collection publishes in. One row per unit on the menu. The bar is the root-mean-square scatter about that unit's own best rescaling of ΔE2000, over 374 pairs of surfaces differing by a fraction of a unit to about ten. A bar of zero would mean the unit is ΔE2000 in different money — every printed number would change and no conclusion would. ΔE2000's own row is zero by construction and is the check that the table is computed the right way round. The two units that divide a chroma difference by the chroma it was measured at, ΔE94 at 15 per cent and CAM16-UCS at 24, are closer to it than the three that do not, which run from 28 to 35. The split is by weighting and not by whether the unit is a matching difference or an appearance one.

The weighting is the disagreement

Five colour-difference formulae, three decades and two committees, and the single property that predicts which of them agree is whether a chroma difference gets divided by the chroma it was measured at. It sorts the menu exactly, it cuts across the distinction between a matching difference and an appearance one, and it halves the census's largest sensitivity.

difference · Metric
The census along the line from ΔE76 to ΔE94, and past it. ΔE94 is ΔE76 with two weighting constants in it, and at zero those constants make every weight exactly one, so the two formulae are joined by a line rather than separated by a choice. The horizontal axis is how much of the published weighting is applied: 0 is exactly ΔE76, 1 is exactly ΔE94, and 3 is three times more weighting than anybody has proposed. The falling curve is the census's mean elasticity to how saturated its test set is, which drops from 1.11 to 0.74 — most of the fall happening before the published value is reached. The other curve is Kendall's τ against ΔE2000's ranking, and it peaks at w = 0.5, not at 1: the weighting that best reproduces the published ordering is about half the published weighting. There is no value of this dial that reaches ΔE2000, whose rotation term is not on this line at all.

A dial through a discrete menu

ΔE*94 is ΔE*ab with two weighting constants in it, and at zero those constants make every weight exactly one — so the two ends of the oldest disagreement in colour difference are joined by a line rather than separated by a choice. Walking it gives a derivative where a menu gives only a spread, and the derivative says the published weighting is on the far side of the interesting part.

difference · Metric
Which steps of the census ranking a change of unit reverses. Every adjacent pair in the published census ranking that at least one unit puts the other way round. The bar counts how many of the five other units reverse it. The marker on the left says whether the test set had already declared the pair unresolved — a gap smaller than twice its own paired standard error, which is a statement about sampling over 125 surfaces and shares no arithmetic with a change of ruler. The two pairs every unit reverses are both flagged, which is the agreement. The pair at the bottom is the disagreement: the test set resolves it at 9.1 standard errors and four of the five units reverse it anyway, because a sampling error cannot see a change of ruler and a change of ruler cannot see a sampling error.

Two instruments and one ranking

A sampling error over a hundred and twenty-five surfaces and a change of colour-difference formula share no arithmetic at all, and they were asked the same question of the same table. Every adjacency the whole menu reverses had already been flagged as unresolved. And one the test set settles at nine standard errors is reversed by four of the five formulae, which is what makes them two instruments rather than one.

limits · Limits
Where on the scale the units disagree. The reference pairs split into bands by how far apart they are in ΔE2000, with each unit's root-mean-square relative departure from the published one plotted per band. Every unit is calibrated once, over the whole sample, so a band is not refitted and the shape is the effect rather than an artefact of fitting. Every one of the five falls: the disagreement is proportionally largest on the pairs that are closest together, which is the opposite of what being fitted to threshold data would suggest. The appearance unit is the extreme case, at 91 per cent on the narrowest band and 17 on the widest, because CAM16-UCS raises its distance to the power 0.63 and a power below one inflates small differences against large ones. In absolute terms every curve here runs the other way — the widest band disagrees by 1.16 to 2.37 ΔE₀₀-equivalent against 0.14 to 0.68 on the narrowest — so which reading is right depends on whether the published quantity is a level or a ratio. This is the mechanism behind the census's own behaviour, where the mildest rows spread furthest across the menu.

The disagreement is at the near end

Every colour-difference formula on the menu was fitted to threshold data, so the expectation is that they agree about pairs an observer can only just tell apart and diverge on large differences. They do the opposite. Proportionally the disagreement is largest at the near end, by a factor of six for the appearance unit, and the cause is an exponent of 0.63.

difference · Metric
What six of this collection's published numbers do when the unit changes. Six quantities, from six calculations that share nothing: a change of light after an observer has adapted, a camera profile's error, the gap between the two standard observers, a metameric pair under the lamp that breaks it, the same image on two papers, and an observer two seconds into a new room. Each is recomputed under all six units and every unit is calibrated onto ΔE2000's scale first, so the bar is not a change of units in the ordinary sense. The bar is the ratio of the largest reading to the smallest, and it runs from 1.71 to 2.30. Five of the six are printed in ΔE2000 by the essays that report them; the sixth is printed in CAM16-UCS, because the model it comes out of defines that unit.

The observers differ by a unit's worth

The gap between the 1931 and 1964 standard observers is the one quantity in this collection's audit with no published number under it — nothing here reports it as a single figure over a stated set. It also has the second-largest dependence on which colour-difference formula is used, running from 1.60 to 3.55 across the menu.

matching · Gamut
MacAdam's twenty-five ellipses, measured in each unit. The uniformity instrument used here, applied to units rather than to spaces. The upper bar is anisotropy — the mean over the twenty-five of the largest radius divided by the smallest, where 1 would be a circle. The lower is spread — the largest mean radius divided by the smallest across all twenty-five, which asks whether a step of the same size means the same thing in different parts of the diagram. Reading down the three CIELAB-based formulae in the order they were published, the anisotropy falls 3.42 → 2.89 → 2.74 and the spread rises 3.24 → 3.59 → 4.12: the weighting divides a difference by the chroma it was measured at, which equalises directions at a point and unequalises magnitudes between points. Neither number is scaled, so no calibration is applied here. CAM16-UCS is ahead on both.

A unit rests on a space that was ranked

This collection ranks three colour spaces by how nearly they make MacAdam's ellipses circles, and CIELAB comes last. It then publishes every difference it computes in a formula built on CIELAB. Turning the same instrument on the formulae rather than the spaces shows the repair works — and that it buys roundness by paying in evenness.

matching · Gamut
Pairs built to sit exactly on a ΔE2000 tolerance, read in every other unit. Twenty-four pairs of surfaces, each constructed by walking one member along a fixed direction until the difference is exactly 1.0 ΔE2000 under D65. The bar spans what those same pairs read in each unit, after calibration, with the tick at the mean. ΔE2000's own row is a point at 1.0 by construction. Every other unit spreads them: ΔE*uv reads them from 0.69 to 1.75, so a contract written at "one unit" accepts and rejects a different set of deliveries depending on which unit it means. CAM16-UCS rejects all twenty-four: it reads the closest of them at 1.43.

A tolerance is a boundary through pairs

Twenty-four pairs of surfaces built to sit exactly on a ΔE2000 tolerance of one read from 0.69 to 1.93 in the other five units. A contract quoting "one unit" without naming the formula does not become slightly wrong in another; it accepts and rejects a different set of deliveries, and in one case rejects every single one.

applied · Delivery
Two sensitivities from two libraries, under every unit. Two quantities that share no code, no test set and no physical question: how much the adaptation census's residual depends on how saturated its surfaces are, and how much a camera profile's reported error depends on how saturated its test chart is. The first is a mean over fourteen changes of light built from cosine combinations; the second is one number about one silicon sensor scored on Gaussian bumps. Under the published unit they sit at 0.687 and 0.656. Across the whole menu they move together, from about 0.5 under the appearance unit to about 1.15 under plain CIELAB, staying within 12 per cent of each other at the worst point. Two numbers agreeing once is a coincidence; two curves agreeing at six points across a factor of two and a half is a shared mechanism, and the mechanism is the compression the unit applies to a chroma difference.

The coincidence was a mechanism

Two sensitivities from two libraries with no shared code came out two per cent apart, and the claim made about them was that they share a mechanism rather than a number. That claim has a colour-difference formula inside it, so it can be tested by changing the formula — and both curves move together across the whole menu, from 0.5 to 1.15.

imaging · Capture
A camera matrix refitted to minimise each unit, rather than solved in XYZ. Every camera profile here, and as far as can be told every camera profile anybody ships, is a linear least-squares solve in XYZ. That is an objective and it is on nobody's menu: it weights a difference by how large the tristimulus values are. Each row here refits the same 3×3 by direct search to minimise one of the six units instead. The upper bar is how much better the fit gets in that unit; the lower is how far the matrix itself moves, as a relative Frobenius norm. Both matter and they do not agree: CAM16-UCS moves the matrix least, at 0.34 per cent, for the largest improvement of the six, while ΔE*94 moves it 6.8 times as far for less. A score that changes is a report changing; a matrix that changes is the camera rendering different pixels.

The objective nobody chose

Every camera profile here, and as far as can be told everywhere, is a linear least-squares solve in tristimulus space. That is an objective and it is on nobody's menu — it weights an error by how bright the patch is. Refitting the same matrix to minimise a real colour-difference formula improves the fit in all six, and moves the matrix, which means different pixels rather than a different report.

imaging · Capture
What six of this collection's published numbers do when the unit changes. Six quantities, from six calculations that share nothing: a change of light after an observer has adapted, a camera profile's error, the gap between the two standard observers, a metameric pair under the lamp that breaks it, the same image on two papers, and an observer two seconds into a new room. Each is recomputed under all six units and every unit is calibrated onto ΔE2000's scale first, so the bar is not a change of units in the ordinary sense. The bar is the ratio of the largest reading to the smallest, and it runs from 1.71 to 2.30. Five of the six are printed in ΔE2000 by the essays that report them; the sixth is printed in CAM16-UCS, because the model it comes out of defines that unit.

A model judged in another model's unit

An appearance shift is a change in what an observer would report, not a change in a stimulus, so measuring one with a matching difference means first asking what stimulus a settled observer would need to be shown to give the same report. That step is not bookkeeping — it is the whole distinction the field rests on, and it costs a factor of 1.7 across the menu.

brain · Appearance
How much of the residual a partial correction removes. Between the diagonal gain and the exact matrix there is a line: apply the correction that would make a row exact, but only a fraction of it. The horizontal axis is that fraction and the vertical is the share of the row's residual it removes, for all fourteen census rows. The straight diagonal is where a correction worth exactly its fraction would fall, and in the published unit every curve lies on it to within 2.2 percentage points. The lower band of curves is the same interpolation measured in CAM16-UCS, which departs by up to 17 points — because its distance is a power of the Euclidean one and a power is not homogeneous along a ray, where every ordinary norm is. The straight line is therefore a property of the ruler rather than of the correction, and the exception is what says so.

A partial correction is worth its fraction

Between a diagonal gain and the exact matrix there is a line, and a bounded observer's natural hope is that the first part of it is worth a disproportionate share. It is not. On all fourteen changes of light, at every setting, the share of the residual removed matches the share of the correction applied to within 2.2 percentage points — which closes the last way the gap could have been cheap.

scene · Scene
What six of this collection's published numbers do when the unit changes. Six quantities, from six calculations that share nothing: a change of light after an observer has adapted, a camera profile's error, the gap between the two standard observers, a metameric pair under the lamp that breaks it, the same image on two papers, and an observer two seconds into a new room. Each is recomputed under all six units and every unit is calibrated onto ΔE2000's scale first, so the bar is not a change of units in the ordinary sense. The bar is the ratio of the largest reading to the smallest, and it runs from 1.71 to 2.30. Five of the six are printed in ΔE2000 by the essays that report them; the sixth is printed in CAM16-UCS, because the model it comes out of defines that unit.

Three choices reached

Two rounds ago this collection named three things it rested on and could not audit — a unit, a diagonal and a template. All three are now reached, and the interesting part is not the three answers but that four of the round's own predictions were refused by the arithmetic and one of its measurements was wrong in a way only a cross-check caught.

limits · Limits
A departure against how far the sample sits from the light. The sample is mixed with a flat reflectance, from the flat one at the left to its own at the right, and two observers differing in the macular pigment look at each mixture. The straight line is the distance between their relative cone excitations, and it is straight to 0.0 per cent: the departure is a pairing, and scaling one factor scales the product. The curved line is the same sequence in ΔE₀₀, which is not a linear function of the excitations and cannot be — it has cube roots in it and a chroma weighting underneath. The identity is about the eye; the curvature belongs to the unit.

A departure is straight in the excitations

Walk a sample a quarter of the way from the light towards its own reflectance and exactly a quarter of the observer disagreement remains — in cone excitations, to two parts in a hundred. In ΔE₀₀ the same quarter leaves 0.347 where proportionality wants 0.428, and the discrepancy belongs entirely to the unit.

difference · Metric
One surface dimmed sixteen times, and the two things that happen to it. A single surface, dimmed by successive halvings, with the lens age departure measured on it at every level. The tristimulus deviation falls by exactly the dimming factor — 16 times over the sweep, to the last bit, because the colour integral is linear in the stimulus. What a unit of that deviation is worth rises by 8.2 times over the same sweep. The colour difference the audit reports is the product of the two, and it falls by only 1.95.

A deviation is not a difference

The previous round priced twenty departures in colour differences and treated each number as a property of the thing that departed. Every one of them is a product of two factors — how far the reading moved, which is linear and belongs to the departure, and what a unit of that movement is worth where it landed, which is not linear and belongs to the colour. Dimming one surface sixteen times scales the first by exactly sixteen and the second by eight.

matching · Gamut
The angle between two departures, which nothing in the audit records. Every pair of the six departures on every surface — 2520 pairs — binned by the angle between their two deviations in the local metric. The distribution reaches both ends: 440 pairs sit under thirty degrees and point almost the same way, and 615 sit above a hundred and fifty and point almost opposite. On 1095 of the 2520 the two together cost less than the larger of them alone. A table of magnitudes cannot say which case it is in.

A size is not a direction

An audit that reports magnitudes cannot say what two of them cost together. Over two and a half thousand pairs of observer departures the angle between them in the local metric runs from one degree to a hundred and seventy-nine, and on forty-three per cent of them the two together cost less than the larger of the two alone. Adding the angle predicts the composition to one and a quarter per cent; Pythagoras is out by twenty-eight.

matching · Gamut
The straight piece under the cube root, and where it stops. CIELAB's lightness against relative luminance, over the bottom 5.0 per cent of the range. Below Y = 0.008856 it is a straight line of slope 7.787; above it, a cube root. The two meet at L* 8 in value and in slope, exactly — the CIE's two constants are chosen to make that true. The dashed curve is the pure cube root, which reaches negative lightness before it reaches zero luminance and has an infinite slope there. The break is marked, and the axis runs to Y = 0.050.

The straight piece under the cube root

CIELAB's lightness is described everywhere as a cube root and below a stated luminance it is a straight line, spliced on with two constants chosen so the join is exact in value and in slope. Every black a delivery chain reaches is inside that straight piece — a press black at L* 2.4, a projected black at 1.1 — where the compression does not compress, the price of a deviation is flat to two parts in a thousand, and the second derivative the composition of two departures needs does not exist.

matching · Gamut
What one tolerance accepts, around four colours. The surface in tristimulus values that ΔE₀₀ 1.0 draws around four colours, each outline scaled to its own size so the shapes can be compared. The volumes they enclose differ by a factor of 1.0e+5 across the sRGB cube, and the longest axis of one shell is between 3.3 and 29.9 times its shortest. A tolerance is written as one number and is a different set of samples at every colour it is applied to.

What one number accepts

A delivery tolerance is written as a single colour difference and it acts on three tristimulus values, so what it actually accepts is a closed surface. Measured over sixty-four colours in the sRGB cube, the volume inside that surface varies by a factor of a hundred thousand and its longest axis is between three and thirty times its shortest. The same contract, applied to a dark colour and a light one, is two different requirements.

matching · Gamut
What a code lattice costs, and where. Twelve thousand colours quantised to 8 bits per channel through the sRGB transfer function and read back, with lightness across the bottom and the colour difference the rounding cost up the side. The mean is 0.191 and the worst case is 1.15, a factor of 6.0. The bars are band means, and they rise: the encoding spends its codes in the shadows, so the top of the ramp is where the lattice is coarsest against a metric that does not compress as hard.

A lattice has no derivative

Every departure priced here was priced by perturbing something and reading the answer, which requires the thing being perturbed to have a derivative. A file written on a code lattice does not have one — its output is flat almost everywhere and jumps on a set of measure zero — so quantisation can be bounded and never propagated. The bound is 1.15 colour differences at eight bits per channel against a mean of 0.19, and it is worst where the encoding spends fewest codes.

matching · Gamut
Two primaries mixed, and the line a reader assumes they take. The additive mixture of two sRGB primaries, walked in twenty steps, plotted in the a and b of CIELAB. The filled points are where the light actually goes, which is exactly straight in tristimulus values because that is Grassmann's second law. The open points are the straight line between the two readings. They part company by 26.7 ΔE₀₀ at their furthest, at 60 per cent of the way along, and the half-and-half mixture misses the midpoint by 21.1.

The mixture line bows

Grassmann's second law says an additive mixture is exactly linear in tristimulus values, and tested here it is exact to floating point. Nothing downstream of the three numbers preserves it. The physical half-and-half mixture of two colours sits a median of 5.5 colour differences from the midpoint of their two readings and up to thirty; on a green and a blue display primary it is twenty-one, which is a quarter of the distance between them.

matching · Gamut
The audit's six departures, read twice. Each departure priced in the matching unit it was published in and in the appearance unit an appearance prediction would be judged by. The model does not scale them by one factor: it amplifies the smallest by 1.58 and the largest by 1.03, so the range between them narrows from 3.34 to 2.17. The mean ranking is unchanged and 14 of the 42 surfaces reorder.

The audit, read as appearances

The previous round priced six observer departures in a matching unit and left them there. Read in the appearance unit an appearance prediction would actually be judged by, they are not the same six numbers scaled by a constant — the model amplifies the smallest by 1.58 and the largest by 1.03, so the range between the largest and smallest term narrows from 3.34 to 2.17. The published ranking survives in the mean and changes on fourteen of the forty-two surfaces it was averaged over.

brain · Appearance
The budget's three numbers, and the units they are in. The published three-stage budget's own figures, with each one's unit named, beside the same stage re-measured in a single unit over the same colours. Two of the three are colour differences between stimuli and the third is a distance between appearances, and the budget adds them. The fourth row is a stage the budget has no entry for: the colours the separation cannot reach even after the mapping has moved them, which comes to 1.45.

The budget adds two units

This collection publishes a three-stage error budget for a colour-management chain and prints its sum. Two of the three stages are colour differences between stimuli and the third is a distance between appearances, and the conversion between those is not a constant. Re-measured in one unit over the same colours the chain has four stages rather than three, its end-to-end error is 5.05 against a sum of 7.66, and the profile's contribution where a job actually lands is 3.2 times its published average.

applied · Delivery
Which way each tolerance is tightest, colour by colour. Sixty-four colours on a lattice through the sRGB cube, with lightness across the bottom. For each, the tolerance ΔE₀₀ 1 is pulled back into tristimulus values and its shortest and longest axes are found. The filled points are the angle between each colour's shortest axis and the direction common to all of them: a median of 15 degrees, ninety per cent within 32. The open points are the same for the longest axis, at 23. The common short axis is 3.1 degrees from X up and Y down, which is the direction of a*.

A tolerance has a grain

A colour tolerance pulled back into tristimulus values is a long thin shape, and across the whole sRGB cube its shortest axis points the same way, fifteen degrees off at the median — the direction in which X rises as Y falls, which is the direction of a*. So what one colour difference allows depends on which way a delivery drifts. An instrument's X filter may age 1.4 per cent before the tolerance is used up, its Z filter 5.1, and the light on the sample 9.3.

matching · Gamut
Four mixtures of display primaries, bowing by different amounts in two units. The half-and-half mixture of each pair of sRGB primaries, measured from the midpoint of the two readings as a share of the pair's own separation. The upper bar is ΔE₀₀ and the lower is the appearance model's J′a′b′. In ΔE₀₀ green and blue bows most, at 25 per cent; in the model it is red and blue, at 20, and blue and yellow falls from 22 to 12. The right-hand column gives the model's distance with its power correction, which is smaller than the Euclidean one for every pair here.

Which mixture bows most depends on the ruler

The physical half-and-half mixture of two lights misses the midpoint of their two readings in any unit a person is shown, and the share it misses by is about the same in ΔE₀₀ and in the appearance model's own space — 12.8 and 14.6 per cent at the median. Which mixtures miss most is not. The rank correlation between the two units is 0.57, a display's blue and yellow is the worst pair in one and the mildest in the other, and the smaller number usually quoted for the appearance model is its power correction rather than a straighter line.

matching · Gamut
The length of one grey ramp, cut into more and more steps. A neutral ramp from L 1 to L 100 cut into between one and ten thousand equal steps, each step measured and the steps added, in four units, both axes logarithmic. ΔE*ab and the model's Euclidean J′a′b′ give the same length at every step count, 99 and 96. ΔE₀₀ settles at 74.6 once the steps are small. The power-corrected ΔE′ does not settle: 25 in one step, 137 in a hundred, 755 in ten thousand, growing as the number of steps to the power 0.37.

A distance raised to a power has no length

CAM16-UCS's colour difference is its Euclidean distance raised to the power 0.63 and multiplied by 1.41. That is still a metric — the triangle inequality holds on every one of four thousand random triples — and it has no length. A grey ramp from black to white measures 25 units in one step, 137 in a hundred and 755 in ten thousand, growing as the number of steps to the power 0.37, and halving the size of a step triples the number of steps that fit.

difference · Metric
The angle between the lens and the macular pigment, before and after adaptation. On each of 120 surfaces the angle, in the local metric, between what an older lens does to the reading and what a denser macular pigment does, binned in ten-degree steps. Read without adaptation, where both filters yellow the observer's white along with everything else, the two point nearly the same way: a median of 8 degrees. Read after each observer has adapted to its own white, the median is 156, and the two together cost less than the larger alone on 115 of the 120.

Two yellow filters cancel on a slope

An older lens and a denser macular pigment both take blue out of the light, and read before adaptation they move a colour in nearly the same direction, eight degrees apart. Once each eye has adapted to its own white they point a median 156 degrees apart on smooth reflectances and together cost less than the lens alone. On surfaces with a narrow absorption band they still sit 26 degrees apart and add. What decides it is the width of the surface's own features.

difference · Metric
How far the chain falls short of its sum, and how much of that is the unit. For each rendering intent, three ratios of the chain's end-to-end error to the sum of its four stages. The lowest bar is the published one, in the power-corrected unit. The middle bar is what that unit reports for a chain whose stages point the same way and add exactly — the exponent on its own. The top bar is the same chain measured in the model's own Euclidean space. Under the colorimetric intent the published ratio is 0.66, the exponent alone gives 0.74 and the chain in a space that can add 0.84: 77 per cent of the shortfall is the unit.

A chain measured in a unit that cannot add

A delivery chain's four stages, measured in the power-corrected appearance difference, sum to 7.66 while the chain end to end measures 5.05, and the shortfall was read as the stages partly cancelling. A chain whose four stages lay in a straight line and added exactly would still read 0.74 of its sum in that unit, because a distance raised to the power 0.63 cannot add. Measured in the model's own Euclidean space the same chain reaches 0.84 of its sum. Three quarters of the published shortfall was the exponent.

applied · Delivery
Where a press's variation lies, and where the tolerance charges for it. Each printed patch's sheet-to-sheet variation under four stated mixes of press variation, split along the three axes of a one-unit ΔE₀₀ tolerance at that patch, tightest first. The upper bar of each pair is the share of the variation along each axis and the lower the share of the price, averaged over 29 patches. For an even mix the tightest axis holds 1.5% of the variation and pays 29% of the price, and the loosest holds 83% and pays 36%. For inking alone the tightest axis holds 2.0% of the variation and pays 34% of the price, and the loosest holds 79% and pays 28%. For a gain-led press the tightest axis holds 1.8% of the variation and pays 29% of the price, and the loosest holds 83% and pays 39%. For a trap-led press the tightest axis holds 1.6% of the variation and pays 29% of the price, and the loosest holds 82% and pays 35%.

A press is charged for the direction it barely moves

A press run varies almost entirely along the direction a colour tolerance forgives. Split along the tolerance's own axes under four stated mixes of press variation, its tightest axis holds about one per cent of the sheet-to-sheet variation and pays a quarter to a third of the price — and on a blue overprint four fifths, for the balance between two inking units rather than the level of either.

matching · Gamut
The angle between the two filters against how completely the eye has adapted. The angle, in the local metric, between what an older lens does to a reading and what a denser macular pigment does, on 120 smooth reflectances, as the degree of adaptation runs from nought to one. The median angle is 8 degrees unadapted and 156 at complete adaptation, and almost all of the turn happens in the last tenth: it passes a right angle at a degree of 0.928. The marks are the degrees CIECAM16 gives five rooms — an overcast sky 1.00, an office 0.94, a lit living room 0.86, a dim room 0.75, a cinema 0.66 — so only the outdoor one is at the end of the dial.

Two filters cancel only in a bright enough room

An older lens and a denser macular pigment cancel each other once an eye has adapted — and that result belongs to the end of a dial nobody stands at. Read at the degree of adaptation CIECAM16 gives an ordinary room, the two barely cancel; in a living room they add, and in a cinema they cost six times what they cost under the sky. The room has to be about as bright as an office before the cancelling begins at all.

difference · Metric
The same pairs, held at one colour difference, read in a unit that knows the room. 23 pairs of reflectances built to sit at exactly ΔE₀₀ 1.000 under D65, read in CAM16-UCS as the adapting luminance runs from a third of a candela a square metre to ten thousand, in an average surround. ΔE₀₀ has no argument for the room, so in that formula every pair stays at 1.000 all the way across — the flat line. In the model's unit the same pairs rise from a median of 0.76 to 1.30, and they do not rise together: at the bright end they run from 1.11 to 1.65.

A tolerance has no light level

Twenty-three pairs built at exactly one colour difference stay at exactly one in every room, because the formula has no argument for the room. Read in the unit that does have one, the same pairs are 0.72 in a cinema, 1.04 in an office and 1.30 in direct sun — and inside any one room they spread by half again, so no single conversion between the two units exists at all.

difference · Metric
What is left of one colour difference when the two colours alternate. 23 pairs built at exactly ΔE₀₀ 1.000, alternated at a rate, with each part of the difference scaled by its own temporal channel and the formula then applied unchanged. At rest every pair is the flat line at one. By 7 hertz the median is 1.11 and the pairs run from 0.57 to 3.04 — a factor of 5.3 between pairs the formula calls identical. By sixty hertz the largest of them is 0.15.

A difference has no rate

A colour difference formula answers for two patches that are both there and stay. Alternate the same two colours and the difference is not scaled but taken apart: the colour half is gone by fifteen hertz and the lightness half is four times louder at eight, so twenty-three pairs the formula calls identical run over a factor of six at the rate the eye is best at, and are worth nothing at all above sixty.

difference · Metric
The straight line between two colours, and the formula's own shortest path. Five gradients seen from above, in the a and b plane of CIELAB: the straight line between the two colours in grey, and the shortest path under ΔE₀₀'s own local metric in colour. The lightness coordinate bows too and is not drawn. red to green saves 3.6 per cent and leaves the straight line by 13; blue to yellow saves 7.5 per cent and leaves the straight line by 21; cyan to magenta saves 3.9 per cent and leaves the straight line by 10; black to white saves 0.0 per cent and leaves the straight line by 0; red to blue saves 0.3 per cent and leaves the straight line by 4 CIELAB units at the widest. Black to white is the flat case: its shortest path is the straight one.

The straight line is not the shortest gradient

A colour difference formula says what a small step costs at every colour, and that is enough to ask which path between two colours is shortest. It is not the straight line: between red and green the shortest path bows thirteen CIELAB units away, saves four per cent — and stays inside sRGB on every step where the straight line leaves it. The formula's own answer for the two endpoints, meanwhile, is neither length.

matching · Gamut
The metamerism index, computed three ways, as the reference match loosens. The special metamerism index of 6 metameric pairs under an incandescent test light, against how well each pair matches under the reference light. Uncorrected, the index absorbs the reference mismatch and rises from 2.86 to 3.76. Corrected multiplicatively it rises to 3.31 and additively to 3.87. All three are the same number when the pair matches exactly, which is the only case the definition covers.

The metamerism index has two corrections

The index for a metameric pair is defined for a pair that matches exactly under the reference light, and no real pair does. The standard's remedy is to correct the sample first, and it names two corrections — scale the tristimulus values, or add the difference. On six pairs matched to one colour difference, the two answers differ by a tenth to four tenths of an index unit; at two, by a whole one.

matching · Gamut
How much of a display's gamut each observer names differently. Each of 60 observers names every colour of the displayable gamut that the panel can make — 823 of them — and the histogram is how much of that gamut each observer names differently from the standard observer. On an OLED panel the median observer renames 8.1 per cent and the furthest 13.1 per cent. Nobody agrees with the standard observer about all of it.

A name moves with the reader

Three earlier essays have moved a colour's name by changing the distance function, the room and the space. All three held the observer fixed. Handed the same light from the same display, sixty observers rename between 3.5 and 13.1 per cent of the gamut against the standard observer, a quarter of its colours have a dissenter in twenty, and the narrower the display's primaries the worse it gets.

brain · Appearance
One grey scale, three backgrounds. CIECAM16's lightness against the luminance factor of a neutral sample, with only the background changed. A grey reflecting 19% reads 46.7 on a near-black background and 32.8 on a near-white one. The three curves are not three shapes: each is the same curve raised to a different power, because the background reaches lightness only through the exponent z, which runs 1.621 to 2.374 across the three.

A dark background moves every difference and no match

CIECAM16's background is one number, and it reaches lightness as one exponent. That is enough to change what a grey looks like and not enough to change which of two greys is lighter — so a match survives the background exactly, a corresponding colour is invariant to it, and a tolerance is not. The effect the background is usually invoked to explain is absent from the model entirely.

brain · Appearance
A crispening term puts the peak where the background is. How much lightness the model returns for a small change in the sample's level, against the sample's level measured as a log ratio to the background's — so that all three backgrounds share one axis and a peak at the background is a peak at zero. The pale curves are CIECAM16 as it stands, which has no peak anywhere: they rise slowly and monotonically because a background that enters as four constants fixed before the sample arrives cannot know where the sample sits relative to it. The solid curves are the same model with a term of amplitude 6 and width 0.5 added to lightness. Each peaks at zero to within 0.000 of a log unit, and the peak's height is 12.00 lightness units per log unit of level — the amplitude divided by the width, exactly.

The cancellation is exact and cheap to lose

CIECAM16 has no crispening, and adding one was expected to be expensive: the background's exactness in a corresponding colour comes from its being a common exponent, and a function of the sample's own level is not one. It is expensive in kind and not in size. A term that raises a straddling pair's lightness difference by half moves a corresponding colour by five thousandths of a tristimulus unit — a thousandth of what stating the background differently at the two ends already costs.

brain · Appearance
Every pair of departures, before adaptation and after it. The fifteen pairs of the six audited observer departures. Each row runs from the angle between that pair's two deviations with no adaptation to the angle with complete adaptation; an angle past ninety degrees is a pair pointing apart, which is where a pair can cost less together than the larger of the two costs alone. 3 pairs gain that behaviour as the eye adapts, 3 keep it, 5 lose it and 4 never have it. The pair followed here — the lens against the macular pigment — is in the smallest group that is not empty, and every result quoted from it generalises in the wrong direction.

Adaptation turns more pairs off than on

One pair of observer departures was followed across the degree of adaptation and found to cancel only in a bright enough room. The same calculation takes any two, and run over all fifteen pairs it says something the single pair does not: adaptation is a rotation rather than a mechanism for making departures oppose each other. Five pairs lose their cancellation as the eye adapts, three gain it, three keep it and four never have it — and the pair everybody quotes is one of the three it turns on.

difference · Metric
Six departures, and three ways of adding them up. The six audited observer departures on 120 smooth reflectances, across the dial. Summing them assumes they all point the same way and is an overestimate everywhere; taking the largest alone assumes only one matters and is an underestimate everywhere. Quadrature — the usual way of combining contributions taken to be independent — assumes they are mutually perpendicular, and the measured combination crosses it at a degree of 0.8618. Below that the departures are on balance pointing together and quadrature is too small; above it they are on balance pointing apart and quadrature is too large. It is exactly right in one room.

Quadrature is exact in one room

An observer allowance is built by adding the departures in quadrature, which assumes they are mutually perpendicular. Over fifteen pairs their angles run from 18 degrees to 179 and hardly any are perpendicular. Measured against the real combination, quadrature is too small in a cinema by eight per cent and too large under the sky by fourteen, crossing at an adapting luminance of 22 candelas a square metre — and on individual surfaces it is out by a third in both directions in every room.

difference · Metric
Three stored-value defects, before the eye and after it, a print at 40 cm. Each defect's largest colour difference between the version computed on stored values and the version computed on light, read twice: as a pixel carries it, and after both images have been through the visual system's three channels at 83 pixels a degree. The two rankings are not the same. The unsharp mask has the largest error per pixel — 16.62 — and keeps only 38 per cent of it; the corner has the smallest at 7.14 and comes out at 9.87. The filter is not a blur applied to a difference: it is applied to each image, and the difference is taken after.

The eye keeps the lightness errors

Four essays have priced what a resize taken on stored values costs, in colour differences between pixels. A reader does not see a pixel. Put the two versions of each image through the visual system's own three channels and the ranking reverses: the unsharp mask, the largest error per pixel at 16.6, is seen at 6.3 on a printed page, while the corner's 7.1 is seen at 9.9. What decides it is not the size of an error but how much of it is colour.

applied · Delivery
Two uniform spaces, two answers: cyan to magenta. The gradient from above, in the a and b plane. The grey line is the straight path in CIELAB; the two coloured curves are the shortest paths under ΔE₀₀'s own local metric and under CAM16-UCS's. They are 15.7 CIELAB units apart at their furthest, against bows from the straight line of 9.9 and 12.2. Both spaces are published as uniform and both are used to decide what lies between two colours; they do not agree.

Two uniform spaces disagree about between

ΔE₀₀'s own local behaviour says which colours lie between two colours, and so does CAM16-UCS's. They do not agree. On cyan to magenta the two shortest paths run fifteen CIELAB units apart — more than either runs from the straight line — and on that gradient ΔE₀₀ would rather have the straight line than CAM16-UCS's answer. Getting the comparison at all takes noticing that one of the two has no local metric: its published difference is a Euclidean distance raised to the power 0.63, and a power below one has an infinite derivative at zero.

matching · Gamut
What a gamut charges a gradient, against what the relaxation's noise is. For each gradient, how much longer the best path that stays inside sRGB is than the free shortest path, as a percentage of the free one. The shaded band is the relaxation's own noise, measured by relaxing the same free path from two different starting points: 0.42 per cent at its worst. Every excess is inside it. So holding a gradient inside a display's gamut costs nothing measurable in the metric's own units, on any of these pairs — including the ones whose free path is outside at most of its points.

A gamut charges a gradient nothing

On red to green the shortest path happened to stay inside sRGB where the straight line did not, and that was called a coincidence of mechanism. Made into a measurement it is not a coincidence: constraining a path to stay inside the gamut costs less of the metric's own length than the relaxation's own noise, on every gradient tested — including the ones whose free shortest path is outside at fifteen of its twenty-one steps. The gamut's boundary and the metric's cheap region point the same way, and the price of the constraint is nothing.

matching · Gamut
How often the choice of correction changes a pair's grade. Eighteen metameric pairs walked to each of eleven reference mismatches, with the share whose index falls in a different band under the two corrections the standard allows. At an exact match the share is zero and must be: there is nothing for either correction to correct. It rises to 44 per cent at a reference mismatch of 2, which is the quality a dyehouse reaches rather than the quality a laboratory constructs. The banding is a five-step convention at 0.5, 1, 2 and 3, stated here rather than quoted, and how much the count depends on it is drawn separately.

The ambiguity is largest where the index is used

The metamerism index is defined for a pair that matches exactly under the reference light, no real pair does, and the two corrections the standard allows for the residual give different answers. Over eighteen pairs at eleven match qualities the gap is nearly a function of the mismatch alone — its middle half spans a factor of 1.4 at the mismatches a dyehouse reaches — so it could be tabulated. And it is largest exactly there: zero at a laboratory's match, and re-grading eight pairs in eighteen at a trade's.

matching · Gamut
Three uniform spaces, three answers: red to blue. The gradient from above, in the a and b plane: CIELAB's straight line, and the shortest paths under ΔE₀₀'s local metric, under CAM16-UCS's and under Oklab's, whose shortest path is its own straight line carried back into CIELAB. They bow from CIELAB's line by 14.4, 42.5 and 42.6 units. ΔE₀₀'s and CAM16-UCS's paths run 28.3 apart at their furthest, Oklab's runs 29.0 from ΔE₀₀'s and 5.6 from CAM16-UCS's, and the space furthest from the other two here is ΔE₀₀.

A third space breaks the tie only once

ΔE₀₀ and CAM16-UCS disagree about which colours lie between two colours. Oklab was the obvious tie-breaker, and it breaks the tie on one gradient of five: on red to blue its path runs within six CIELAB units of CAM16-UCS's and twenty-nine from ΔE₀₀'s. On red to green and cyan to magenta it keeps to CIELAB's straight line while both others bow, and on blue to yellow it bows further than either. Each of the three spaces is the odd one out somewhere. Asking also exposed a CAM16-UCS path that had never converged.

matching · Gamut
The same gradients, priced by a penalty and by a projection. Each row is one gradient held inside a coated press from six starts. The pale dots are the penalised relaxation — a free step, with a price for leaving the press — and the dark ones are the projected relaxation, which takes the free step and then moves each point to the nearest printable colour. Across is how much longer than the free path each result is, logarithmic. On the 10 gradients whose straight line leaves the press, the penalty leaves 9 starts at more than twice the free length and the projection leaves none. The projection's best route costs a median 0.02% against the penalty's 0.13%, and its spread across starts is 0.95% against 132.5%.

A projection has no reason to detour

Holding a gradient inside a press by penalising the excursion turned the gamut's price from a number into a search: on five of ten crossing gradients some starting point leaves the relaxation trapped at more than twice the free length, and the spread across six starts runs to 271 per cent of the free path. Replacing the penalty with a projection — take the free step, then move each point to the nearest printable colour — leaves no trap on any gradient and a spread of 0.06 to 2.4 per cent.

matching · Gamut
How much of a coated press is left at each margin inside its boundary. The share of a coated press's printable volume in CIELAB that lies at least a given distance inside its boundary, for margins from half a unit to 32. A margin of one unit keeps 88%, two keep 80%, four 66% and eight 45%. At every margin up to 30 what is left is a single connected piece; at 31 units, with 0.14% of the volume left, it first splits, into a core of 623 cells and 2 fragments of one or two cells — the deepest point is 32.7 units inside, so what splits is the last crumb of the core, not a waist.

A margin costs a press its corners

A gradient held inside a coated press by projection was predicted to tear if the press were first shrunk by a safety margin, at any pinch narrow enough for the shrinking to cut. The press has no such pinch: shrunk by any margin up to thirty CIELAB units it stays in one piece, and projected routes on it are neither trapped nor torn. What a margin costs is concentrated at the corners — the solid yellow moves nearly four times the margin to get inside, like the tip of a 31-degree spike.

matching · Gamut

Named alongside it

The objects these essays reach for when they reach for this one.

CIEDE2000Test setSpecificationToleranceChromatic adaptationCalibrationCIELABResidualSensitivityChromaCIECAM16Uncertainty

All concepts