Concept

Observer metamerism — where it appears

Two spectra that match for one observer and not for another, which is what a metameric match costs when the observer changes. It is the failure a change of light cannot repair, because the observer rather than the illuminant is what differs.

Named by 44 essays across 8 fields — each of them below, with the objects they name alongside it.

The CIE 1931 colour-matching functions. The three functions that turn a spectrum into three numbers. They are all positive, which is why XYZ exists — the RGB functions they were derived from are not. ȳ is by construction the luminous efficiency function, which is why luminance comes out of Y.

Seventeen observers in 1931

The standard observer that governs every colour specification in industrial use is an average over seventeen young British men, measured with equipment from the 1920s. It is known to be wrong in the blue, the correction has existed since 1951, and it has never been adopted.

limits · Limits
How far a match comes apart when the observer changes. A broad source and a three-primary source, solved at each primary width so the pair is an exact tristimulus match for the CIE 1931 observer. The pair is then handed to the 1964 observer, and the gap between them is plotted. For the observer they were built for the gap is arithmetic noise at every width. For the other it grows as the primaries narrow, reaching 0.012 at 10 nm — and displays have been getting narrower for twenty years.

Whose eyes

The standard observer is an average over seventeen people, and no reader is it. What that costs was small when displays were broad and grows every time the primaries get narrower.

limits · Limits
Three retinas of different composition, making identical colour matches. Seeded mosaics at L:M ratios of 1, 4, 16 to one — the range found between people, and a 16-fold difference in what the retina is made of. A colour match is the claim that two spectra produce equal excitation in all three cone classes, and changing how many of a class there are multiplies that class's excitation by a constant, which cannot disturb an equality. The relation between the two test spectra is identical to twelve decimal places across the whole sweep. Luminance, which is a weighted sum rather than an equality, moves by 1.33× over the same range. That asymmetry is why a standard observer exists and why V(λ) has a much larger between-observer variance than the colour-matching functions do.

The mosaic is not the observer

The ratio of long-wavelength to medium-wavelength cones varies between ordinary people by a factor of sixteen. Those people make the same colour matches, to twelve decimal places, and that single fact is the reason a standard observer can exist at all.

eye · Cones
How far a match comes apart when the observer changes. A broad source and a three-primary source, solved at each primary width so the pair is an exact tristimulus match for the CIE 1931 observer. The pair is then handed to the 1964 observer, and the gap between them is plotted. For the observer they were built for the gap is arithmetic noise at every width. For the other it grows as the primaries narrow, reaching 0.012 at 10 nm — and displays have been getting narrower for twenty years.

Two degrees or ten

This site names the observer on every figure it draws, which was supposed to be the point. Measuring what it had actually done found two hundred and four figures naming the same observer, three naming the other, and sixty-two of sixty-four generators printing a string that had never once varied.

limits · Limits
The L cone's sensitivity at three axial pigment densities. Each curve is normalised to its own peak, so the only difference visible is shape. Raising the density from 0.1 to 0.9 widens the curve from 113.6 to 145.9 nm at half height while the peak stays within 5 nm of where it was. That is Beer–Lambert saturating: at the peak the pigment already absorbs nearly everything, so more of it can only catch more light in the wings.

A cone absorbs its own light

A photopigment's absorbance is a property of a molecule; a cone's sensitivity is that molecule stacked in a column deep enough to absorb most of what arrives. The stacking broadens the curve by thirty-five nanometres, and two observers differing in nothing else disagree about a match that is exact for one of them.

eye · Cones
One match, and what it says about the observer making it. The anomaloscope: a monochromatic 589 nm yellow set against a mixture of 545 and 670 nm. Only two cone classes respond at those wavelengths, so the match is two equations in two unknowns and has one solution for any observer whose two pigments differ. The bar is the fraction of the accepted band; the mark is the solution. A normal observer accepts 0.7 per cent of the scale; an observer whose two pigments are the same accepts all of it, because their two equations are one equation twice. Nothing here is fitted to clinical data: the pigments are the same template used for every observer here, at stated peaks, and the match is the solution of the linear system.

One match names the observer

A yellow at 589 nanometres set against a mixture of 545 and 670 is two equations in two unknowns. It has one solution for a normal observer, a solution somewhere else for an anomalous one, and no unique solution at all for a dichromat — whose two equations are one equation twice.

matching · Gamut
One light, two eyes. The same stimulus through two sets of ocular media differing only in macular pigment (0.35 and 0.41) and lens age (55 and 55 years). Compared under one white the two differ by ΔE00 1.00; compared with each eye adapted to its own long-run white — which is what the visual system does — by 0.00. The second number is why nobody notices, and the first is why a person who has had one lens replaced reports that the other eye has turned yellow.

Nobody here has two eyes

One person's two eyes differ in macular pigment and lens density, so the same light produces two colours — a whole ΔE00 apart for an ordinary pair, seven for one replaced lens. Adaptation hides it exactly, which is why nobody notices and why nothing in colorimetry has a term for it.

limits · Limits
A fourth primary, swept — every setting an exact match, none of them the same. Four primaries matching three numbers leave one degree of freedom. Along the horizontal axis it is the fourth primary's share of the white's luminance; at each value the other three powers are solved exactly, so every point on this plot is a floating-point-exact match for the reference member — worst residual 1.3e-15 — and no colorimeter can tell them apart. What the population sees runs from 13.7 ΔE00 at the ninety-fifth percentile to 17.3, a factor of 1.26. The best setting is the largest share the arithmetic admits, so what stops it is not colour but the requirement that four powers stay positive.

Four primaries have a choice

Three primaries matching three numbers have one answer. Four have a family of them, every member exact to floating point for the observer they were solved for — and the members are not equally good for anybody else, so a display with a fourth primary has a setting that is robust to who is looking at it and a setting that is not.

matching · Gamut
One tolerance decision, at four spectral distances. Every column is a pair of samples ΔE00 1.0 apart for the observer a colorimeter models — solved to that value by bisection, so the instrument would report the same number for all four. What differs is how far apart the two spectra are, which is achieved by adding a metameric black the reference observer cannot see. The bands are what two hundred people report: from 1.13 at the ninety-fifth percentile when the spectra are the same shape to 2.32 when they are not, and the worst case reaches 3.7. No specification records the quantity on the horizontal axis.

A tolerance is a probability

A colorimeter reports one number and a specification compares it with another, and both are computed for an observer who does not exist. Handed to two hundred people, the same pair at ΔE00 1.0 is read from 0.8 to 3.7 — and which of those two ranges applies depends on something no specification records.

difference · Metric
What the same eye reports about one field, in the middle and at the edge. Each row is a uniform field, drawn at the most saturated version of itself this page can show — the percentage is how much of the full stimulus survived, the rest being the adapting light added to bring it inside the gamut. The left patch is what the centre of gaze reports and the right one what 10 degrees out reports, each adapted to the same light as that position sees it. The adapting white comes out identical to 5e-13, because an adapted eye cancels its own filter exactly. Nothing else does, and the largest difference is in the blue. tungsten light is not drawn: it cannot be shown at any useful saturation, and at full strength it differs by ΔE00 1.87.

One person is two observers

The macular pigment is a yellow screen over the fovea and nowhere else, so a cone at the centre of gaze and a cone ten degrees away have different colour-matching functions in the same eye. A match made in the middle comes apart at the edge by six units — and fitting one filter to the gap between the CIE's two standard observers gives a density of 0.40 against a measured 0.35.

eye · Cones
A colour rendering index, computed for everybody instead of for one observer. Each bar spans what 120 eyes make of one lamp: the same reflectances, the same reference illuminant, the same arithmetic, different colour-matching functions. The mark is the standard observer's own answer, which is the number printed on the box. One lamp's spread is 3.8 points wide while the whole range the standard observer puts these lamps in is 1.8 — so a ranking quoted to a tenth of a point is a statement about one set of tables. Two of the marks fall outside the population's range entirely.

The index is one observer's opinion

A colour rendering index is printed to a tenth of a point and computed for a single set of colour-matching functions that no standard names as a choice. Scored by two hundred eyes instead, one lamp's spread is wider than the whole range the standard observer puts five lamps in — and two lamps the standard separates by four tenths of a point come out the other way round for every member of the population.

light · Light
What a fourth primary actually buys. All three displays are floating-point-exact matches for the reference observer, so no colorimeter can tell them apart. The bars are the 95th percentile of what two hundred other eyes report. Held to the same gamut floor of 1.4× sRGB, the four-primary design leaves the population 2.6 times closer together than the three-primary one. That is what the extra emitter is worth, and it is not more colour — the gamut is held fixed while it is measured.

A fourth primary is a design

A display's fourth emitter is sold as more colour. Optimised instead against how far apart two hundred eyes are about its white — with the gamut held fixed so it cannot cheat — it buys agreement, and two and a half times closer together than three primaries reaching the same area, and the wavelengths it chooses are not the ones anybody would pick.

matching · Gamut
One tolerance decision, about pairs that agree less and less about the spectrum. Every point is a pair of samples that the reference observer reports as exactly ΔE00 1.0 apart — the same number, the same decision, the same line in the same specification. Along the axis is how far apart their two reflectances are. Up the side is the 95th percentile of what two hundred other eyes report. It runs from 1.13 to 2.32. The document records the horizontal line and not the axis it is plotted against.

A tolerance needs a second number

Two samples one colour difference apart can be read almost identically by everybody or two units apart by the worst-off twentieth, and which of those it is depends on how far apart their spectra are — a quantity every spectrophotometer has already measured and none of them prints. Adding it as a second field predicts the population three times better, and at the tolerances where it matters it is right about a third of the decisions the difference alone gets wrong.

difference · Metric
How wrong a camera profile is, and who it is wrong for. A colour matrix fitted against the 1931 observer, evaluated four ways. Its residual against that observer is ΔE00 0.92 — the Luther failure, which is a property of the sensor and is the honest measurement of the camera. Against a person drawn from a population of 160, the worst-off twentieth report 3.35. And a camera with no spectral error whatever, reporting the standard observer's own tristimulus values exactly, would leave 3.47. The camera is not the problem. It was fitted to somebody who does not exist, and so is the standard it was fitted against.

Fitted to an eye nobody has

A camera profile's residual against the observer it was fitted to is under a unit, and that is the number everybody quotes. Against a person drawn from a population it is 3.35 at the ninety-fifth percentile — and a camera with no spectral error whatever, reporting the standard observer's tristimulus values exactly, would carry 3.47. The camera is not the problem.

imaging · Capture
Every claim here that was computed with one model, recomputed with two. Each row is a claim one of these essays makes. The bar is how many times the two-model answer differs from the one-model answer, on a logarithmic scale. 3 of 13 have no bar at all: the first model's answer for them is exactly zero, not because it computed zero but because it has no variable for the quantity. Those are the rows where a second model did not correct an answer — it supplied one.

What a second model changed

Thirteen claims here, each computed with one model and recomputed with two. Ten of them move by half again or more. Three of them do not move at all in the ordinary sense — the first model's answer is exactly zero, not because it computed zero but because it has no variable for the quantity — and every one of those three is a join that supplied a state or a device rather than a spread.

limits · Limits
The share of itself each change leaves behind, and the smallest is inside the eye. The residual as a fraction of the change rather than as a colour difference, which sorts the census differently. At the top is the macular pigment — the filter in front of the central few degrees of one's own retina — leaving 2.4 per cent of itself. It is a fixed transmittance multiplying the light and the white together, which is as close to a pure gain as anything here gets, and it is why nobody notices they have one.

The filters inside the eye

The macular pigment leaves 2.4 per cent of itself after adaptation — the smallest share of anything in this site's census of light changes, and less than half the next smallest. Fifty years of lens yellowing leaves 7.9 per cent, and the difference between the two says what a gain is actually good at.

eye · Cones
Which of these paints the display can show, and to how many people. Each row is a real surface under D65, and the bar is the share of 120 observers for whom a non-negative mixture of this display's three primaries reproduces it. The question has no observer-free answer: the paint is a reflectance, the primaries are emission spectra, and whether one matches the other is a fact about somebody's cones. A dot marks the rows the 1931 observer calls displayable. 2 of them are rows some real people cannot see, and 4 more go the other way.

A gamut has a population

Whether a display can reproduce a paint is a fact about somebody's cones, so the boundary of a gamut is not a curve but a band. On a laser projector, ten of twenty-eight boundary surfaces are ones the standard observer calls displayable and some real people cannot see — and the wider the gamut, the wider the band.

matching · Gamut
The conditions under which an observer's departure is exactly zero. A departure of the observer is the pairing of something belonging to the observer with something belonging to the stimulus, so emptying either factor empties the product. The axis is logarithmic in what is left when the condition is imposed. Six rows empty the stimulus's factor — a perfectly neutral sample is the same colour for every observer, at any age and any field size — and two empty the observer's, since a gain on each cone and a change of basis are both absorbed exactly. All eight are identities rather than small numbers. The last two are the same two conditions imposed in a published cone space rather than in the observer's own, and they are worth eight and thirteen units: the identity is about the eye, and the arithmetic everybody uses is in somebody else's coordinates.

A neutral is everyone's colour

Two eyes differing by fifty years of lens yellowing, by a factor of three in macular pigment and by six nanometres of long-wavelength peak agree about a grey card to four parts in ten thousand billion. The agreement is an identity rather than a coincidence, and it says exactly what an observer disagreement is a disagreement about.

eye · Cones
Every departure under every light. Six departures across six lights, each cell the difference between two observers in ΔE₀₀, drawn as a bar whose length is the number. The rows are not multiples of one another: the lens is worst under tungsten and the pigment peaks are worst under a three-emitter LED, because a departure is a pairing and which light is being paired with decides it. The laser projector's row is empty, and that is not a fact about lasers — on this collection's five-nanometre grid a three-line spectrum is a one-line spectrum, and a single wavelength is a stimulus every observer agrees about exactly.

The lens is worst under tungsten

An ageing lens costs 4.38 ΔE₀₀ under a tungsten lamp and 2.20 under a fluorescent tube. The pigment peaks cost 2.84 under a three-emitter LED and 1.87 under the same tube. Six departures across six lights do not form a single ordering, which is what a pairing looks like and what a dominant term would not.

eye · Cones
Each departure over forty-two surfaces rather than one. The same six departures measured over a family of forty-two analytic reflectances — an absorption band of stated centre, width and depth — with the smallest, the median, the ninety-fifth percentile and the largest marked. Every one of them spans more than a factor of three, and the ranking between them is not stable across the family: what decides a departure's size is which sample it is asked about, because a departure is a pairing and the sample is one of the two factors. Quoting any single number for what an observer's age is worth is quoting a choice of example.

The ranking is not stable

On a red pigment under daylight the six observer departures run from 2.38 down to 1.20 ΔE₀₀. Over forty-two surfaces two of them change places, the top two separate, and every one spans between a factor of ten and a factor of thirty-five. A chart of six bars is a chart of one example.

eye · Cones
What this collection's grid does to its own observer audit. Two bars per light: the mean departure of the observer computed on this collection's five-nanometre grid, and the same computation on a quarter-nanometre one. For five of the six lights the two agree to two decimal places, which is what a well-sampled spectrum looks like. For the laser projector the coarse answer is exactly zero and the fine one is 2.34 — the largest in the table. On a five-nanometre grid a three-line spectrum with lines at 465, 532 and 638 nanometres is a one-line spectrum, and a single wavelength is a stimulus every observer agrees about to the last bit. The two departures do not compound here; the first conceals the second.

The grid hid the observer

On this collection's five-nanometre grid a three-laser projector's observer disagreement is exactly zero. On a quarter-nanometre grid it is 2.34 ΔE₀₀ and the largest in the table. The two audits of this round meet here, and the first one does not compound with the second — it removes it.

limits · Limits
What this collection's grid does to its own observer audit. Two bars per light: the mean departure of the observer computed on this collection's five-nanometre grid, and the same computation on a quarter-nanometre one. For five of the six lights the two agree to two decimal places, which is what a well-sampled spectrum looks like. For the laser projector the coarse answer is exactly zero and the fine one is 1.80 — the largest in the table. On a five-nanometre grid a three-line spectrum with lines at 465, 532 and 638 nanometres is a one-line spectrum, and a single wavelength is a stimulus every observer agrees about to the last bit. The two departures do not compound here; the first conceals the second.

One wavelength is everyone's colour

A stimulus with a single wavelength in it produces the same relative cone excitations for every observer, exactly, whatever their age or field size. A display made of three such stimuli is where observers disagree most. Both statements are consequences of the same algebra, and the second is why laser projection has an observer problem.

matching · Gamut
The three cone absorptances at two settings of the age of the lens. Solid and dashed are the same construction at the two ends of twenty years old against seventy. The curves are built from one pigment template through its ocular media, which is the same model its population of two hundred eyes is drawn from. The largest difference between the two sets is 25.5 per cent of the peak, and where it sits along the wavelength axis is what decides which stimuli the two observers disagree about — a departure concentrated in the blue is invisible on a sample with no blue in it.

The observer has no age

Five of the six arguments in this round are spreads — a population differs about them and the mean is a reasonable summary. The lens is not. Everybody's lens yellows in the same direction at about the same rate, so a standard observer with no age is not an average over a population; it is a snapshot of one moment in every reader's life.

eye · Cones
The three cone absorptances at two settings of the macular pigment. Solid and dashed are the same construction at the two ends of two standard deviations of the reported spread. The curves are built from one pigment template through its ocular media, which is the same model its population of two hundred eyes is drawn from. The largest difference between the two sets is 31.5 per cent of the peak, and where it sits along the wavelength axis is what decides which stimuli the two observers disagree about — a departure concentrated in the blue is invisible on a sample with no blue in it.

The macular is a band, not a filter

The lens absorbs everything below 500 nanometres with a long tail; the macular pigment absorbs forty nanometres either side of 460 and nothing else. The two have similar sizes and completely different distributions, and the reason is that one is broad and one is narrow — which is what decides whether a sample is affected at all.

eye · Cones
The three cone absorptances at two settings of the pigment peaks. Solid and dashed are the same construction at the two ends of two standard deviations, and the L/M polymorphism on top. The curves are built from one pigment template through its ocular media, which is the same model its population of two hundred eyes is drawn from. The largest difference between the two sets is 8.9 per cent of the peak, and where it sits along the wavelength axis is what decides which stimuli the two observers disagree about — a departure concentrated in the blue is invisible on a sample with no blue in it.

The peaks move the flanks

Shifting a cone's peak wavelength by three nanometres changes its sensitivity at its own maximum by almost nothing and on its flanks by several per cent, because a maximum is flat and a flank is steep. Every display primary sits on a flank, which is why a pigment polymorphism is worth 3.60 ΔE₀₀ under a laser projector.

eye · Cones
The arguments a standard observer does not have. Seven choices inside a set of colour-matching functions, each with the shape it takes and what it is worth in ΔE₀₀ on a red pigment under a 6500 K radiator. Six are measurements: a field size, an age, a macular density, a cone optical density, three peak wavelengths and a rod contribution. The seventh is not — a change of basis is a change of curves and not a change of observer, and its entry is exactly zero because the space an experiment measures is what an observer is. Printing that zero beside the others is the clearest statement of what the other six are measurements of.

An observer is a contract

Six departures, all above a delivery tolerance, none dominant, and no reader matching the standard on any of them. That would be a demolition if the standard observer were a description of an eye. It is not — it is an agreement about what a number means, and an agreement is not falsified by being unlike anybody.

limits · Limits
Each departure over forty-two surfaces rather than one. The same six departures measured over a family of forty-two analytic reflectances — an absorption band of stated centre, width and depth — with the smallest, the median, the ninety-fifth percentile and the largest marked. Every one of them spans more than a factor of three, and the ranking between them is not stable across the family: what decides a departure's size is which sample it is asked about, because a departure is a pairing and the sample is one of the two factors. Quoting any single number for what an observer's age is worth is quoting a choice of example.

A tolerance with an observer in it

A delivery tolerance is written in ΔE₀₀ against the 1931 observer, and six departures of that observer combine to about three of the same units on an ordinary saturated sample. A one-unit tolerance is being asked to contain a three-unit uncertainty that nothing in its budget mentions.

difference · Metric
The conditions under which an observer's departure is exactly zero. A departure of the observer is the pairing of something belonging to the observer with something belonging to the stimulus, so emptying either factor empties the product. The axis is logarithmic in what is left when the condition is imposed. Six rows empty the stimulus's factor — a perfectly neutral sample is the same colour for every observer, at any age and any field size — and two empty the observer's, since a gain on each cone and a change of basis are both absorbed exactly. All eight are identities rather than small numbers. The last two are the same two conditions imposed in a published cone space rather than in the observer's own, and they are worth eight and thirteen units: the identity is about the eye, and the arithmetic everybody uses is in somebody else's coordinates.

The instrument is one observer exactly

A spectrophotometer has no observer uncertainty. It computes through the 1931 tables to the last bit, reproducibly, forever — which is its whole value and is also why it cannot report the three colour differences of observer spread between itself and whoever is looking at the sample.

applied · Delivery
The same white, matched at six primary widths. At every width the three primaries are solved to match D65 exactly for the reference member; the bands are what the population sees. A broad primary integrates the observer differences over a band and averages them away; a narrow one samples them at a point and passes them straight through. From 40 nm to 2 the ninety-fifth percentile rises from 11.3 to 17.9 ΔE00, monotonically, and the technology has been moving from left to right for thirty years.

A narrow primary buys a disagreement

The observer audit decomposes what a display costs a population. Narrowing the primaries raises the pigment-peak departure monotonically, moving one raises or lowers the macular departure, and the two respond to different design variables — so a wide gamut and an observer-robust display are bought with the same money.

matching · Gamut
Each departure over forty-two surfaces rather than one. The same six departures measured over a family of forty-two analytic reflectances — an absorption band of stated centre, width and depth — with the smallest, the median, the ninety-fifth percentile and the largest marked. Every one of them spans more than a factor of three, and the ranking between them is not stable across the family: what decides a departure's size is which sample it is asked about, because a departure is a pairing and the sample is one of the two factors. Quoting any single number for what an observer's age is worth is quoting a choice of example.

The chart was measured by an observer too

A camera profile is fitted so that the camera's numbers reproduce the chart's measured tristimulus values. Those values were computed through the 1931 observer, so the fit inherits every departure in this round — and the fit's own residual, at 0.19 ΔE₀₀ on the chart, is fifteen times smaller than the term it cannot see.

imaging · Capture
Every departure under every light. Six departures across six lights, each cell the difference between two observers in ΔE₀₀, drawn as a bar whose length is the number. The rows are not multiples of one another: the lens is worst under tungsten and the pigment peaks are worst under a three-emitter LED, because a departure is a pairing and which light is being paired with decides it. The laser projector's row is empty, and that is not a fact about lasers — on this collection's five-nanometre grid a three-line spectrum is a one-line spectrum, and a single wavelength is a stimulus every observer agrees about exactly.

The booth and the eye disagree

A viewing booth is specified to simulate daylight, and daylight is the light under which observers disagree least. So a booth is the condition in which a specification is least likely to be tested against the thing that breaks it, and the shop it will be judged in roughly doubles the term.

applied · Delivery
Each departure over forty-two surfaces rather than one. The same six departures measured over a family of forty-two analytic reflectances — an absorption band of stated centre, width and depth — with the smallest, the median, the ninety-fifth percentile and the largest marked. Every one of them spans more than a factor of three, and the ranking between them is not stable across the family: what decides a departure's size is which sample it is asked about, because a departure is a pairing and the sample is one of the two factors. Quoting any single number for what an observer's age is worth is quoting a choice of example.

A brand colour for a population

A brand colour is chosen once, specified in a number, and seen by everybody. The observer audit says two candidate colours with identical specifications can carry observer spreads differing by an order of magnitude, and that the spread is computable from an ink's spectrum at the moment the ink is chosen.

applied · Delivery
The conditions under which an observer's departure is exactly zero. A departure of the observer is the pairing of something belonging to the observer with something belonging to the stimulus, so emptying either factor empties the product. The axis is logarithmic in what is left when the condition is imposed. Six rows empty the stimulus's factor — a perfectly neutral sample is the same colour for every observer, at any age and any field size — and two empty the observer's, since a gain on each cone and a change of basis are both absorbed exactly. All eight are identities rather than small numbers. The last two are the same two conditions imposed in a published cone space rather than in the observer's own, and they are worth eight and thirteen units: the identity is about the eye, and the arithmetic everybody uses is in somebody else's coordinates.

Two observers and one metamer

An observer departure is invisible on a single sample compared with nothing. It becomes a disagreement the moment two spectra are being asked to match, because a match is an identity between three integrals and a different observer takes different integrals. Everything in this round is a statement about pairs wearing a single sample's clothes.

eye · Cones
The share of each light outside 380–780 nanometres, as power and as visual product. Two measurements of the same truncation. The upper bar is the fraction of the light's radiant power that lies outside the range; the lower is the fraction of the product of light, sample and observer — which is what a colour is made of. A thermal radiator puts a fifth of its power outside and about a thousandth of its colour, because the observer is zero where most of that power is. The gap between the two bars is the observer's own tails doing their job, and reading the upper number as though it were the lower is how a range gets argued about without being measured.

A lamp is two audits at once

A lamp's ultraviolet content decides what its tabulation costs and its blue content decides what its observer costs, and the two run in opposite directions with colour temperature. So no lamp is good for both audits and no lamp is bad for both, and a single figure of merit for either is a figure of merit for one property of a spectrum.

light · Light
The arguments a standard observer does not have. Seven choices inside a set of colour-matching functions, each with the shape it takes and what it is worth in ΔE₀₀ on a red pigment under a 6500 K radiator. Six are measurements: a field size, an age, a macular density, a cone optical density, three peak wavelengths and a rod contribution. The seventh is not — a change of basis is a change of curves and not a change of observer, and its entry is exactly zero because the space an experiment measures is what an observer is. Printing that zero beside the others is the clearest statement of what the other six are measurements of.

A sensor has no lens

A camera is a fourth observer and it is the only one with none of the six arguments this round measured. It does not age, it has no macular pigment, its response does not broaden with density and its peaks do not vary — so it is perfectly reproducible and is not any of the observers it is fitted to reproduce.

imaging · Capture
The angle between the lens and the macular pigment, before and after adaptation. On each of 120 surfaces the angle, in the local metric, between what an older lens does to the reading and what a denser macular pigment does, binned in ten-degree steps. Read without adaptation, where both filters yellow the observer's white along with everything else, the two point nearly the same way: a median of 8 degrees. Read after each observer has adapted to its own white, the median is 156, and the two together cost less than the larger alone on 115 of the 120.

Two yellow filters cancel on a slope

An older lens and a denser macular pigment both take blue out of the light, and read before adaptation they move a colour in nearly the same direction, eight degrees apart. Once each eye has adapted to its own white they point a median 156 degrees apart on smooth reflectances and together cost less than the lens alone. On surfaces with a narrow absorption band they still sit 26 degrees apart and add. What decides it is the width of the surface's own features.

difference · Metric
A soft proof exact for one observer, as two hundred others see it. Each display is driven to match each of thirty printed patches exactly for the reference observer, so for that observer screen and print are the same colour to fourteen decimal places. The bars are what two hundred observers drawn from the population make of the same pairs: the median observer's difference, median over the patches, and the ninety-fifth percentile observer's: 1.8 and 4.8 on the wide-gamut LCD, 2.0 and 5.4 on the OLED, 3.1 and 7.5 on the laser projector. The narrower a display's primaries, the larger both become.

A soft proof is exact for one reader

A display can be driven to match a printed patch exactly for the standard observer — three equations, three unknowns, agreement to fourteen decimal places. Two hundred observers drawn from a realistic population see the same screen and print a median of 2.1 colour differences apart on an OLED panel and 5.4 apart at the ninety-fifth percentile. On a laser projector the ninety-fifth percentile is 7.5. The patch that fails worst is unprinted paper, and in the chain's own unit the ninety-fifth percentile reader's stage is larger than every one of the four stages a delivery chain is budgeted for.

applied · Delivery
A soft proof exact for one observer, and three proofs tuned for readers. For each display, the median over printed patches of the 95th percentile reader's mismatch between screen and print, for four ways of choosing the display's three drive levels: exact for the reference observer; least squares over a population of a hundred; tuned on that population's 95th percentile; and tuned on the two hundred readers it is scored on, which no workflow could do. On a wide-gamut LCD the four give 4.57, 4.99, 4.74, 4.39, and the three tuned proofs cost the reference observer 0.70, 0.82, 0.69. On an OLED panel the four give 5.12, 5.72, 4.99, 4.86, and the three tuned proofs cost the reference observer 1.35, 0.95, 0.67. On a laser projector the four give 7.54, 7.00, 6.81, 6.50, and the three tuned proofs cost the reference observer 1.88, 1.23, 1.14.

A proof cannot be tuned for readers who disagree

A soft proof matched exactly for the standard observer is five colour differences wrong for one reader in twenty. Giving up that exactness to tune the display's three drives for a population instead moves the ninety-fifth percentile reader by 4 to 14 per cent even when the tuning is done on the very readers it is scored against — because what readers see is mostly each other's disagreement, and three drives act on every reader at once.

applied · Delivery
How much of a display's gamut each observer names differently. Each of 60 observers names every colour of the displayable gamut that the panel can make — 823 of them — and the histogram is how much of that gamut each observer names differently from the standard observer. On an OLED panel the median observer renames 8.1 per cent and the furthest 13.1 per cent. Nobody agrees with the standard observer about all of it.

A name moves with the reader

Three earlier essays have moved a colour's name by changing the distance function, the room and the space. All three held the observer fixed. Handed the same light from the same display, sixty observers rename between 3.5 and 13.1 per cent of the gamut against the standard observer, a quarter of its colours have a dissenter in twenty, and the narrower the display's primaries the worse it gets.

brain · Appearance
Every pair of departures, before adaptation and after it. The fifteen pairs of the six audited observer departures. Each row runs from the angle between that pair's two deviations with no adaptation to the angle with complete adaptation; an angle past ninety degrees is a pair pointing apart, which is where a pair can cost less together than the larger of the two costs alone. 3 pairs gain that behaviour as the eye adapts, 3 keep it, 5 lose it and 4 never have it. The pair followed here — the lens against the macular pigment — is in the smallest group that is not empty, and every result quoted from it generalises in the wrong direction.

Adaptation turns more pairs off than on

One pair of observer departures was followed across the degree of adaptation and found to cancel only in a bright enough room. The same calculation takes any two, and run over all fifteen pairs it says something the single pair does not: adaptation is a rotation rather than a mechanism for making departures oppose each other. Five pairs lose their cancellation as the eye adapts, three gain it, three keep it and four never have it — and the pair everybody quotes is one of the three it turns on.

difference · Metric
Six departures, and three ways of adding them up. The six audited observer departures on 120 smooth reflectances, across the dial. Summing them assumes they all point the same way and is an overestimate everywhere; taking the largest alone assumes only one matters and is an underestimate everywhere. Quadrature — the usual way of combining contributions taken to be independent — assumes they are mutually perpendicular, and the measured combination crosses it at a degree of 0.8618. Below that the departures are on balance pointing together and quadrature is too small; above it they are on balance pointing apart and quadrature is too large. It is exactly right in one room.

Quadrature is exact in one room

An observer allowance is built by adding the departures in quadrature, which assumes they are mutually perpendicular. Over fifteen pairs their angles run from 18 degrees to 179 and hardly any are perpendicular. Measured against the real combination, quadrature is too small in a cinema by eight per cent and too large under the sky by fourteen, crossing at an adapting luminance of 22 candelas a square metre — and on individual surfaces it is out by a third in both directions in every room.

difference · Metric
What the rods cost a match, by where their signal enters and under which lamp. For five lights, the median colour difference over forty-two surfaces between the reference observer and the same observer with a rod signal a tenth of each cone's peak added — into all three cone channels, into the long- and middle-wavelength channels only, or into the short-wavelength channel only. Under daylight the first two are 1.03 and 0.90: whether the rods reach the S pathway hardly matters. Under a phosphor white LED they are 1.24 and 0.45, a factor of 2.75, and the S-only route alone costs 0.96.

The rods' route is priced by the lamp

A rod signal in a dim room disturbs a colour match, and how much depends on which of the cone pathways it reaches — a weight the physiology leaves uncertain, especially for the blue–yellow pathway. Under daylight the uncertainty is nearly free: a rod signal that skips the S pathway costs 0.90 at the median surface against 1.03 for one that enters all three. Under a phosphor white LED it is worth a factor of 2.75, 0.45 against 1.24. What decides it is one number per lamp: how large the rod signal is compared with each cone class's own catch of the light.

eye · Cones
How far each lamp's sensor reading is from what the camera predicts, with RGB + clear. Fourteen lamps, six smooth and eight structured, each scored by how far an ambient-light sensor with red, green, blue and clear channels reads from what the camera's white predicts through a map fitted on smooth radiators and daylights. The smooth lamps score at most 0.057 and the structured at least 0.133; the dashed line is the threshold at the gap's geometric middle, 0.087. The lights the map was fitted on score at most 0.0113. Every lamp falls on its own side of the line.

Two sensors disagree about deep red, not lines

A phone's ambient-light sensor and its camera read the same lamp differently, and the difference sorts fourteen lamps into smooth and structured without a single mistake — where flicker made five. It is not reading their lines. Almost all of it comes from the sensor's clear channel collecting deep red the camera's infrared cut throws away, so daylight with its far red trimmed is called structured and a white LED with a far-red emitter is called smooth.

imaging · Capture
The calibration error a narrow fourth channel survives, by where it is placed. For a red, green and blue ambient sensor with one more channel 10 nm wide, centred from 450 to 640 nm: the first calibration error at which some lamp of fourteen is misclassified. Dashed: the channel pooled into the whole residual, as the ambient sensor's disagreement was read; its best is ±1.50 per cent. Solid: the channel read on its own, as its departure from what the camera's white predicts for it; its best is ±4.0 per cent, at 450 nm. Crosses mark centres where the channel read alone does not separate the lamps at all. The two horizontal lines are the red, green and blue design (±1 per cent) and the design with a clear channel (±4 per cent).

A narrow channel has to be read on its own

An ambient sensor with a clear channel tells structured lamps from smooth ones by reading deep red, and one without it reads structure but breaks at one per cent of calibration error. A narrow fourth channel between the camera's peaks was proposed to have both. Pooled into the sensor's disagreement with the camera, it reads structure and breaks at one and a quarter per cent — no better than the design it was meant to rescue. Read on its own, as its departure from what the camera predicts for it, a channel at 450 nm holds to four per cent, the clear channel's figure, and far red does not move it.

imaging · Capture

Named alongside it

The objects these essays reach for when they reach for this one.

Individual variationStandard observerSpecificationMacular pigmentMetamerismQuality controlCone fundamentalsPrimariesNarrow band displaysAcceptabilityColour-matching functionsCalibration

All concepts