Concept

Psychophysics — where it appears

The measurement of what an observer reports as a function of what was presented, which is where every number about perception comes from. Its results are distributions over people rather than constants, and the width of the distribution is usually larger than the effect being averaged.

Named by 11 essays across 5 fields — each of them below, with the objects they name alongside it.

Threshold and suprathreshold contours, normalised to the same size. At five of MacAdam's centres: the measured just-noticeable-difference ellipse in grey and the ΔE2000 = 1 contour in gold, each scaled to the same mean radius so that only shape and orientation are being compared. A scale change preserves orientation exactly, so any rotation between the pair settles the question. They differ by 24° on average and by 70° at worst, and the ratio between their sizes varies 4.8-fold across the diagram — so no single factor turns one into the other.

A threshold is not a unit

MacAdam measured the smallest difference anyone could detect. ΔE2000 was fitted to how far apart plainly different colours look. The two are quoted interchangeably, and the contours they produce are not even the same shape.

difference · Metric
Every claim here that was computed with one model, recomputed with two. Each row is a claim one of these essays makes. The bar is how many times the two-model answer differs from the one-model answer, on a logarithmic scale. 3 of 13 have no bar at all: the first model's answer for them is exactly zero, not because it computed zero but because it has no variable for the quantity. Those are the rows where a second model did not correct an answer — it supplied one.

What a second model changed

Thirteen claims here, each computed with one model and recomputed with two. Ten of them move by half again or more. Three of them do not move at all in the ordinary sense — the first model's answer is exactly zero, not because it computed zero but because it has no variable for the quantity — and every one of those three is a join that supplied a state or a device rather than a spread.

limits · Limits
A stabilised grating fades at a rate that depends on which way its bars run. What is left of a 0.3 cycle-per-degree grating, in multiples of its own threshold, as a function of its orientation, at four moments after the image was stabilised on the retina. The first curve is flat to floating point: at the instant the pattern arrives, orientation does not matter, because the filter that carries it has no orientation preference at this frequency. The anisotropy arrives with the fading, reaching ×2.09 after five minutes, and a pool with no axis predicts none of it.

A fading pool has a shape

Giving the local adaptation pool two axes instead of one costs a single parameter and produces a prediction the circular version cannot make — a stabilised grating fades at a rate that depends on which way its bars run. The obvious objection is the oblique effect, and the two act in bands that do not overlap.

eye · Cones
MacAdam's ellipses, drawn on one diagram. The twenty-five measured discrimination ellipses at 10× actual size, on CIE xy (1931). Mean axis ratio 2.95 — one would mean every contour is a circle — and a size spread of 10.42 between the largest and the smallest. Both numbers depend on the plane, which is why the 1976 revision existed; neither can be taken to one, which is why the revision did not finish the job.

No diagram makes them circles

Every chromaticity diagram is a projective picture of the same measurement, so how badly MacAdam's ellipses fail to be circles can be minimised over the whole family of them. The best plane there is still leaves the average ellipse twice as long as it is wide — which makes the residual a fact about the eye rather than about anybody's choice of primaries.

difference · Metric
A gap in the wall and a gap in the drive are not the same gap. What the centre of a region settles to under three conditions. With the contour closed it reaches its border's value exactly. Open a 16% hole in the barrier and leave the border signal unbroken and it still reaches it, to 1e-8 — a ring of driven cells encloses the centre whatever the wall outside it is doing, so nothing can escape. Break the signal too and it falls to 0.960. All of what a gap costs is the piece of border that stopped driving, and none of it is the hole.

A gap in the drive, not in the wall

Break the contour around a region and leave its border signal unbroken, and the interior does not move by one part in a million — a ring of driven cells encloses a centre whatever the wall outside it is doing. Break the signal too and the shortfall goes as the square of what is missing. All of what a gap costs is the piece of border that stopped driving.

scene · Scene
What is left of one colour difference when the two colours alternate. 23 pairs built at exactly ΔE₀₀ 1.000, alternated at a rate, with each part of the difference scaled by its own temporal channel and the formula then applied unchanged. At rest every pair is the flat line at one. By 7 hertz the median is 1.11 and the pairs run from 0.57 to 3.04 — a factor of 5.3 between pairs the formula calls identical. By sixty hertz the largest of them is 0.15.

A difference has no rate

A colour difference formula answers for two patches that are both there and stay. Alternate the same two colours and the difference is not scaled but taken apart: the colour half is gone by fifteen hertz and the lightness half is four times louder at eight, so twenty-three pairs the formula calls identical run over a factor of six at the rate the eye is best at, and are worth nothing at all above sixty.

difference · Metric
How far CIECAM16 moves a monochromatic hue when the light is brightened thirtyfold. A monochromatic stimulus at a relative luminance of 2 and of 60, read through CIECAM16 in one room, and the difference between its two hue angles. The model was never fitted to this effect and has it anyway: the shift is positive at the short end, negative through the greens, positive again in the yellows and reds, and crosses zero at 459, 495, 502, 570 nanometres. The marks are the invariant wavelengths the literature reports — 474, 506, 571.

The model has a hue shift it was never given

A monochromatic light changes hue as it is brightened, except at three wavelengths that do not move — an effect measured since the nineteenth century and not among the things CIECAM16 was fitted to. The model has it anyway: brightening a stimulus thirtyfold moves its hue angle, and the places where the movement crosses zero land at 459, 495, 502 and 570 nanometres against the reported 474, 506 and 571. The sizes are another matter.

brain · Appearance
Which two lamps to stand a mesopic match between. Every pair of the five lights, by how far a match made under one and set under the other moves as the rod signal's weight into the S channel goes from nothing to equal — the median over forty-two surfaces, which is the signal an experiment has to resolve. The best pair is daylight against phosphor LED at 0.58 ΔE₀₀; the worst is tungsten against fluorescent tube at 0.09, a factor of 6. The count at the right is how many settings it takes to resolve the weight to a tenth at half a colour difference of scatter per setting.

The reference lamp must not move

To measure an uncertain weight, use the condition in which the answer depends on it most. That is right about half of an asymmetric colour match and exactly wrong about the other half: a match measures a difference of two displacements, and a reference field that also moves with the weight cancels the signal the test field carries. Daylight is the least sensitive of five lamps and belongs in every one of the three best pairs — 75 settings against a phosphor LED, 2,804 against the pair of lamps the principle as stated would have chosen.

eye · Cones
How each unit balances lightness against chroma, as a display brightens. Twelve pairs built to differ in lightness alone and twelve built to differ in chroma alone, each at exactly one ΔE₀₀, read in both units at nine display levels. Up is the median lightness pair's reading divided by the median chroma pair's, so a falling curve means chroma differences becoming relatively more visible. Both fall. ΔEITP's median runs from 0.91 at a 1.5-candela white to 0.81 at 10,000, a fall of 11 per cent; CAM16-UCS's from 1.13 to 0.87, a fall of 23 per cent. Neither turns: both units say chroma differences gain on lightness differences as a display brightens, and CAM16-UCS says it twice as strongly.

The units part by hue, not by light level

Two colour differences with a light level in them were compared on a display running from 5 to 5,000 cd/m², and a prediction was drawn from how each divided a difference between lightness and chroma. Built into pairs that differ in lightness alone and in chroma alone, both units say the same thing about light level: as a display brightens, chroma differences gain on lightness differences — ΔEITP by a tenth, CAM16-UCS by a quarter. Where they part is hue. The appearance model moves every colour's balance by the same factor; ΔEITP moves the violets, reds and cyan-blues the other way, and at nine of twelve base colours the two units disagree about the direction.

difference · Metric
The appearance model's lightness-to-chroma balance, as the room takes a share of the adaptation. The median lightness pair's reading over the median chroma pair's, for twelve base colours, against the display's white, in a room of 20 cd/m². Solid: CAM16-UCS, with the viewer taking all, three quarters, half, a quarter and none of the adaptation from the display — darker lines take more from the display. Dashed: ΔEITP, which no room enters. With the display alone the model's balance falls 23 per cent; with half from the room, 13; with none from the display it does not move.

A lit room brings the units' medians together

As a display brightens, CAM16-UCS says chroma differences gain a quarter on lightness differences and ΔEITP says a tenth. All of the appearance model's movement comes from what the viewer is adapted to, and every calculation had the viewer adapted to the display alone. Give the room its share of the adaptation and the model's movement shrinks at every step: with a 20 cd/m² room supplying two thirds of it, the two units' medians fall by the same amount. What does not shrink is their disagreement about direction. The model still moves every colour the same way, ΔEITP still moves violets, reds and cyan-blues the other way, and in a lit room that becomes the whole of what separates them.

difference · Metric
How far a mesopic match moves as the S weight opens: two rooms against one field. For every pair of the five lamps, the median over forty-two surfaces of how far a match moves as the rod signal's weight into the S channel goes from nothing to equal: pale for the two-room match, each half adapted to its own lamp; dark for a bipartite field whose two halves share one adaptation. The field's signal is larger for every pair, by ×1.5 to ×7.7.

One field keeps what two rooms divide out

An asymmetric match can measure how strongly the rods feed the blue-yellow pathway, but set with the observer adapted to each lamp in turn it needs seventy-five settings on the best pair of lamps and hours of waiting between them. Putting the two lamps on the two halves of one field was proposed as the quick version, at the cost of a weaker signal. The signal is not weaker. Under one shared adaptation it is three times stronger for daylight against a white LED, and the best pair needs six settings. The adaptation that makes the slow version slow is also what was dividing the rods' contribution out of each half.

eye · Cones

Named alongside it

The objects these essays reach for when they reach for this one.

ΔEThresholdAbsolute luminanceAssertionChromaJust-noticeable differenceModelling assumptionPerceptual uniformityToleranceAdaptationCIECAM16CIEDE2000

All concepts