Concept

Modelling assumption — where it appears

A structural choice inside a calculation — a basis, a grid, a functional form, a metric — as distinct from a value fed into it. It has no range to sweep, so a sensitivity analysis reaches it only by exhibiting it as the limit of some continuous family.

Named by 108 essays across 9 fields — each of them below, with the objects they name alongside it.

How far each census row moves when the test set's own description does. A grid of bars, one row per change of light in the census and one bar in each row per number that describes the region the test surfaces are drawn from: how saturated they are, how bright, and how far the two modulations may go together. A bar's length is the elasticity — the proportional change in the published residual for a proportional change in that number. Saturation runs from 0.49 to 0.91 and brightness averages 0.104, so a test set's chroma range is nearly everything and its lightness range is nearly nothing. For scale, the largest elasticity found anywhere among this collection's five declared population widths is about a half — and those at least have declared ranges, while these three numbers have never been quoted with one.

The input nobody declared

An audit that swept every declared width in this collection found the largest elasticity anywhere to be about a half. The most elastic input turns out to be one that was never declared, never quoted with a range and never varied — and being undeclared is exactly why it escaped the audit that was looking for it.

limits · Limits
Every worst surface sits on a number somebody typed. The region the test surfaces are drawn from, in its own two modulation coordinates: a square of allowed depths with a diamond inscribed in it, the diamond being the requirement that the two depths sum to no more than 0.7. The 14 marked points are the worst surface for each change of light in the adaptation census, found by search over the whole region. Every one of them lies exactly on the diamond, and every one is also at the brightest level the region allows — both declared constraints active, on all 14 rows, with no interior maximum anywhere. That is the opposite of what bounding the wall gave: there the worst case turned over at a band width of six nanometres because a narrow band returns too little light, which is physics. Here the worst case is a reading of two numbers. The one constraint that is about the world — a paint's excitation purity may not exceed 0.6 — is slack everywhere: the most saturated surface the region admits reaches 0.459.

Every worst surface sits on a declaration

Bounding the wall in a painted room produced a real worst case — the residual turns over at a band six nanometres wide because a narrower band returns too little light. Bounding the surfaces the residual is averaged over produces nothing of the kind, because all fourteen answers sit exactly on two numbers somebody typed and the one constraint that comes from the world never binds at all.

scene · Scene
Every census row under five constructions of the same test set. A slope chart with 5 columns — lattice, coarse, fine, uniform, natural — and one line per change of light in the census, each line joining that row's mean residual under each construction. Four of the five columns describe the same region of surfaces walked at different densities or against different measures; the last is the clamped, realistic family, which is not linear in its parameters and is therefore answering a slightly different question. The levels move: between the coarse and fine lattices every row shifts by seven to nine per cent, in the same direction, which is a common-mode factor no published residual here has ever carried. The order almost survives. Inside the region exactly one pair crosses, and it is the pair the standard error had already flagged; under the clamped set two more cross, including one the error separates by nearly nine standard errors. The crossing lines are drawn heavy.

What the audit still cannot reach

Two rounds have now swept every declared width in this collection and one of its structural choices. Three structural choices remain, none of them has a multiplier to sweep, and the reason each resists is different — which makes the list a description of where this kind of audit ends rather than a queue of work.

limits · Limits
The six arguments a surface's response has, and the one this model keeps. A surface's response to light is a function of six arguments: the wavelength, direction and place the light arrives with, and the wavelength, direction and place it leaves with. The model every colour here is computed from keeps one number per wavelength, which means it takes the diagonal of the first pair, integrates the second away, and assumes the third pair equal. Each departure drawn here restores one of them. The fourth departure is not on the diagram: the wavelength grid is the range of the index that was kept rather than an index that was dropped, which is why it is the cheapest of the four to fix and was still not fixed.

The model has six arguments

Every colour computed here is an integral of a reflectance against a light against three curves, and a reflectance is one number per wavelength. A real surface's response is a function of six arguments — the wavelength, direction and place light arrives with, and the three it leaves with — so the model keeps one of them, takes a diagonal, integrates two away and assumes two more equal.

limits · Limits
What the interface does to a reflectance, and the straight line it is taken for. The Saunderson relation between the reflectance inside a pigment layer and the reflectance an instrument reads off it, for a boundary of refractive index 1.50. The curve is the real map; the dashed line joins its two endpoints, which is the straight relation an additive pedestal assumes. They are 0.216 of a reflectance unit apart at their widest, which is 5 times the pedestal itself. The curvature comes from the k₂ term — light reflected back down into the layer from underneath the boundary — which is 0.60 where the outward reflection is 0.04.

A mixture in the variable nobody named

Kubelka–Munk works because absorption and scattering add over a mixture and reflectance does not. What adds is the absorption of the pigment layer, and what an instrument reports is that layer seen through an interface — related by a Möbius function rather than by a constant. Mixing in the reported variable instead of the internal one costs between three and eight ΔE₀₀, and no source this collection quotes says which variable its curves are in.

scene · Scene
Two slabs with one reflectance, and two colours through an aperture. Two constructed media whose bulk reflectance agrees at every wavelength to fifteen figures, and whose diffusion lengths differ by a factor of four. The upper curve is that shared reflectance — both slabs lie on it exactly. The two patches on the right are what a 4 millimetre radius returns from each, and they are 6.3 ΔE₀₀ apart. This is a metamerism with no observer in it: the two samples are the same colour to anybody under any light, and the instrument separates them because it is measuring a kernel through a hole rather than measuring a reflectance.

The appearance model has no slot for it

Two slabs with identical reflectance and different kernels come out of CIECAM16 with identical lightness, chroma and hue — to six decimal places, because the model's input is a stimulus and their stimuli are the same. Translucency is a recognised appearance attribute with no correlate in any appearance model, and the reason is structural rather than an oversight.

brain · Appearance
Which of the collection's published quantities a departure can be pushed through. The six quantities the previous round recomputed under six different colour-difference units, and whether the same treatment works for a departure. Two do: the adaptation census and the metameric pair both take reflectances and a light, which is what a departure acts on. Four do not, and the reasons are different in each case rather than a single obstacle. A unit is a function applied to the answers, so it can be swapped at the end of any computation; a departure changes the object at the start, so it has to be accepted by every stage in between. That is the practical difference between auditing a convention and auditing a structure.

A departure is not a unit

The previous round audited six published quantities by swapping the unit they were quoted in — a function applied at the end of each computation. Nothing of that shape works here. A departure changes the object at the start, so every stage in between has to accept it, and only two of the same six quantities can take one at all. The fourth cannot even be expressed in the interface.

limits · Limits
The six arguments a surface's response has, and the one this model keeps. A surface's response to light is a function of six arguments: the wavelength, direction and place the light arrives with, and the wavelength, direction and place it leaves with. The model every colour here is computed from keeps one number per wavelength, which means it takes the diagonal of the first pair, integrates the second away, and assumes the third pair equal. Each departure drawn here restores one of them. The fourth departure is not on the diagram: the wavelength grid is the range of the index that was kept rather than an index that was dropped, which is why it is the cheapest of the four to fix and was still not fixed.

The audit that changed the object

Three rounds audited this collection's numbers, its sets and its conventions, and each one ended by naming the same thing it could not reach — that a surface is a reflectance. This round reached it, found that four departures share one algebraic form, had two of its predictions refused, and discovered that its own hemisphere quadrature had been passing a convergence check by luck.

limits · Limits
What three fill-in rules cost when a five-nanometre table is read at one. A five-nanometre table read at one nanometre by three rules — hold the value, straight lines, a cubic through four points — each compared with the same tenth-nanometre reference. The dashed rule is the answer obtained by summing the table as it stands, at 0.00000 ΔE₀₀. Two of the three interpolations are worse than not interpolating. That is not a paradox: the summation's error is already small because the normaliser cancels most of it, and an interpolator introduces a shape the original curve did not have, which the cancellation cannot touch. A finer grid is not more resolution when the table is not finer.

A finer reading of a coarser table

Interpolating a five-nanometre spectrum to one nanometre helps a daylight calculation by a factor of five and harms a three-emitter LED by a factor of a hundred and twenty thousand. Both are the same operation on the same table, and which one happens is decided by a property of the light nobody records.

light · Light
How much the answer moves when the 5-nanometre grid is slid through one cell. Each bar is the spread of one light's colour across five grid origins, all at the same 5-nanometre step, in ΔE₀₀. A smooth light barely moves, and what movement it has is the end cells rather than the sampling. The fluorescent tube moves by 3.18 units and the laser projector by 35.0, because their emission lines are narrower than the step and whether a sample lands on one is a coincidence of arithmetic. This is the measurement that separates a quadrature error from an aliasing error, and no average over origins can substitute for it.

Where the grid starts

Holding the step at five nanometres and sliding the grid's origin through one cell moves a fluorescent tube's computed colour by 3.18 ΔE₀₀ and a laser projector's by 35.0. Refining the step does not fix it and averaging over origins hides it. It is the one tabulation fault with no smooth error to cancel against.

light · Light
How far this collection's analytic observer is from the tabulated one. The construction every figure in this family uses is three pigment absorptances through one fitted 3×3, and this is the residual of that fit against the CIE's 1931 functions: root-mean-square error as a percentage of each curve's peak, and the colour difference it produces over forty-two surfaces. The short-wavelength function is the worst at 16.4 per cent, which is where a pigment template is weakest and where the ocular media are doing most of the work. The median colour difference is 1.42 ΔE₀₀, so this is an observer of the right shape rather than a copy of the table — and every departure in this family should be read beside that number rather than against zero.

The reference had to be built

A five-nanometre error cannot be measured with five-nanometre data. Interpolating the tables and integrating finely measures the interpolator, not the grid — so the audit of this collection's index had to be run against an observer made of formulae, and the price of that is a residual of 1.42 ΔE₀₀ that every number in the section is read beside.

limits · Limits
What a tabulation step costs, by light, on paper. The horizontal axis is the tabulation step in nanometres, from one to twenty; the vertical is how far the resulting colour is from the same integral taken at a tenth of a nanometre over the same range, in ΔE₀₀, on a logarithmic scale. Each line is one light. The three with no feature narrower than the step fall smoothly and stay below a tenth of a unit at five nanometres, which is the grid used throughout. The fluorescent tube and the laser projector do not fall at all: their lines are narrower than any step drawn here, so the answer depends on where the samples land rather than on how many there are. The sample is held at paper throughout.

A grid is not a resolution

Ten essays into this collection there is one sentence about wavelength sampling, and it is that five nanometres is enough. Ten measurements later there are three decisions, three mechanisms, three repairs and two rankings, and the word resolution names none of them.

light · Light
What this collection's grid does to its own observer audit. Two bars per light: the mean departure of the observer computed on this collection's five-nanometre grid, and the same computation on a quarter-nanometre one. For five of the six lights the two agree to two decimal places, which is what a well-sampled spectrum looks like. For the laser projector the coarse answer is exactly zero and the fine one is 2.34 — the largest in the table. On a five-nanometre grid a three-line spectrum with lines at 465, 532 and 638 nanometres is a one-line spectrum, and a single wavelength is a stimulus every observer agrees about to the last bit. The two departures do not compound here; the first conceals the second.

The grid hid the observer

On this collection's five-nanometre grid a three-laser projector's observer disagreement is exactly zero. On a quarter-nanometre grid it is 2.34 ΔE₀₀ and the largest in the table. The two audits of this round meet here, and the first one does not compound with the second — it removes it.

limits · Limits
The three cone absorptances at two settings of the rods. Solid and dashed are the same construction at the two ends of a tenth of the cone response, which is a dim room. The curves are built from one pigment template through its ocular media, which is the same model its population of two hundred eyes is drawn from. The largest difference between the two sets is 9.1 per cent of the peak, and where it sits along the wavelength axis is what decides which stimuli the two observers disagree about — a departure concentrated in the blue is invisible on a sample with no blue in it.

The rods are a fourth curve

Colorimetry has three numbers and a rod signal is a fourth. It cannot be absorbed by a gain, it cannot be removed by a white point, and adding a tenth of one to a three-curve observer costs 1.60 ΔE₀₀ — the narrowest distribution of the six departures, because an addition behaves quite differently from a filter.

eye · Cones
The arguments a standard observer does not have. Seven choices inside a set of colour-matching functions, each with the shape it takes and what it is worth in ΔE₀₀ on a red pigment under a 6500 K radiator. Six are measurements: a field size, an age, a macular density, a cone optical density, three peak wavelengths and a rod contribution. The seventh is not — a change of basis is a change of curves and not a change of observer, and its entry is exactly zero because the space an experiment measures is what an observer is. Printing that zero beside the others is the clearest statement of what the other six are measurements of.

An observer is a contract

Six departures, all above a delivery tolerance, none dominant, and no reader matching the standard on any of them. That would be a demolition if the standard observer were a description of an eye. It is not — it is an agreement about what a number means, and an agreement is not falsified by being unlike anybody.

limits · Limits
What the Lambertian assumption costs a room, against how rough its walls are. The horizontal axis is the roughness of the two coloured walls; the right-hand end is nearly matt, which is what a radiosity calculation assumes. One line is the distance in ΔE₀₀ between the floor's colour and what radiosity gives for the same room — 4.89 at an eggshell finish, falling to 0.97 at the matt end. The other is the chroma of the bounce, which falls as the walls get glossier: what an interface returns is a Fresnel reflection and carries no pigment, so the fraction of the return that goes into the lobe is a fraction that arrives at the floor white. The lobe is taken out of the body term rather than added beside it, which is what a real finish does.

The solver had no slot for gloss

Every scene result in this collection is computed by radiosity, and radiosity is not an approximation that could be made more accurate. Its unknown is one number per surface, and a surface that returns light differently in different directions does not have one. A missing slot cannot be wrong by a small amount.

scene · Scene
The directional solver reduces to the radiosity solver exactly. A solver with a new unknown in it is worth nothing until it reproduces the one it replaces. Setting every wall's bidirectional distribution to ρ/π collapses all thirty ordered-pair radiances onto their patch's radiosity divided by π, and the answer agrees with this collection's existing radiosity solution to 9.8e-16 relative — the floating-point floor. That is the check that makes every other number in this family a statement about lobes rather than about a new piece of arithmetic, and it is the reason the reduction is drawn rather than mentioned.

Thirty unknowns instead of six

A directional transport solver is worth nothing until it reproduces the one it replaces. Setting every wall's bidirectional distribution to ρ over π collapses thirty ordered-pair radiances onto six radiosities and reproduces this collection's existing answer to 9.8 × 10⁻¹⁶ relative — which is the only reason anything else it says can be believed.

scene · Scene
What the floor receives, matt walls against walls of roughness 0.2. The spectral radiance leaving the floor towards the front of the room, computed twice. The matt curve peaks at 530 nanometres, where the walls' pigment is. The glossy curve is higher everywhere and higher by relatively more away from that peak, because the extra light is a Fresnel return and a Fresnel return has the lamp's spectrum rather than the paint's. That difference in shape is the desaturation, drawn before it is reduced to a number, and it is the reason the two lines cannot be brought together by any exposure change.

A lobe takes colour out of a bounce

A gloss wall sends more light to the floor and less colour. The extra light is a Fresnel reflection at the interface, it carries the lamp's spectrum rather than the paint's, and it arrives at the next surface white — so a green room in satin paint is less green than the same room in flat paint by nearly a colour difference of chroma.

scene · Scene
Where the viewer stands, at a wall roughness of 0.2. The chroma of the light the floor sends towards each of the five other faces of the room, at one roughness. The spread is 2.00 ΔE₀₀ between the extremes. A radiosity solution assigns one radiosity to the floor and therefore cannot have a spread at all — the whole width of this chart is a quantity the method has no slot for, rather than one it approximates badly. The two side walls see the most because they are where the coloured light comes from, and the direction the lobe favours is the direction it came from.

The floor is a different colour from the door

With a lobe on the walls the floor sends chroma 18.76 towards the front of the room and 20.94 towards the side walls, a spread of two colour differences. A radiosity solution assigns the floor one number, so the whole of that spread is a quantity the method has no slot for rather than one it estimates badly.

scene · Scene
Two ways of putting a lobe on a wall, and the sign they disagree about. The chroma of the floor's return against the wall's roughness, computed twice. In one the interface's return is taken out of the body term — light reflected at the boundary never reaches the pigment, which is what a real finish does. In the other it is added beside the body term, which is what a microfacet model does if nobody couples the two. The first says a gloss wall makes the room less coloured and the second says more, and the gap at the glossiest end is 2.87 units of chroma. Neither is a numerical error; the difference is a modelling decision that is usually made by omission.

Two ways to put a lobe on a wall

Take the interface's return out of the body term and a gloss wall makes the room less colourful. Add it beside the body term and the same wall makes the room more colourful. Same solver, same room, one line of energy accounting, and the two answers differ by nearly three units of chroma at the glossy end.

scene · Scene
Where a point-sampled patch stops resolving a lobe. The horizontal axis is the wall's roughness, logarithmic; the vertical is how far the answer moves when the cone quadrature is refined from eight directions to sixteen, also logarithmic. A patch in a cube subtends a cone of angular radius 25.8° at the face opposite, and a microfacet lobe of roughness a is about a radians wide, so a lobe below about 0.15 is narrower than the quadrature that samples it. The movement at 0.05 is 21.2 ΔE₀₀ and at 0.3 it is 0.033. This is where the method stops, not where the paint does: matt, eggshell and satin finishes are inside it and a high-gloss varnish is not.

Where a patch stops being a point

A patch in a cube subtends a cone of 25.8° at the face opposite. A microfacet lobe of roughness 0.05 is about three degrees wide. Point-sampling the second inside the first returned a chroma of thirty-four thousand and a negative lightness, and the boundary between working and not working is measured rather than declared.

limits · Limits
The lobe's share of what leaves a surface of body reflectance 0.5. For light arriving at 45°, the fraction of what leaves the surface that is the interface's Fresnel return rather than the pigment's. It runs from about 9.1 per cent at an eggshell finish down to 4.2 at a matt one. That is a small share, and it is the whole of the effect: a tenth of the return arriving white is enough to move the room's colour by units of ΔE₀₀, because the bounce is what a room's colour is made of and every bounce is multiplied by the next.

A tenth of the return arriving white

Nine per cent of what leaves a satin wall is a Fresnel reflection carrying no pigment. That nine per cent moves the room's colour by 4.89 ΔE₀₀ and its chroma by five per cent, because an interreflection multiplies and a small contribution with a different spectrum compounds into a large one.

scene · Scene
What the Lambertian assumption costs a room, against how rough its walls are. The horizontal axis is the roughness of the two coloured walls; the right-hand end is nearly matt, which is what a radiosity calculation assumes. One line is the distance in ΔE₀₀ between the floor's colour and what radiosity gives for the same room — 4.89 at an eggshell finish, falling to 0.97 at the matt end. The other is the chroma of the bounce, which falls as the walls get glossier: what an interface returns is a Fresnel reflection and carries no pigment, so the fraction of the return that goes into the lobe is a fraction that arrives at the floor white. The lobe is taken out of the body term rather than added beside it, which is what a real finish does.

Every scene in this collection was matt

The green wall, the corner, the bounce series and the metamer separation are all computed on Lambertian surfaces, because the solver that produced them requires it. Each would move by between one and five colour differences on an ordinary satin finish, and none of those essays says what finish it means.

scene · Scene
The pairing against the direct computation, for each departure that admits both. Each departure can be computed twice: directly, by taking the difference between the fuller model and the integral one, and as a pairing — an inner product of the sample's deviation with the light's. The bar is how far apart the two answers are, relative to the answer, on a logarithmic axis. The three directional rows agree to a part in a thousand billion, which is the arithmetic of one shared quadrature. The lateral row agrees to three parts in a hundred thousand, and the gap there is the radial quadrature rather than the identity: the two integrals are taken over different grids. The pairing is not an approximation to the departure. It is the departure, written so that its two factors are separate.

Three audits and one shape

The tabulation, the observer and the scene solver have nothing in common as subjects. Each turned out to hold a departure that is a pairing of two deviations, vanishes exactly when either is empty, and had been invisible because its parameter had no call site. Three subjects, one shape, and the shape is the round's result.

limits · Limits
The conditions under which an observer's departure is exactly zero. A departure of the observer is the pairing of something belonging to the observer with something belonging to the stimulus, so emptying either factor empties the product. The axis is logarithmic in what is left when the condition is imposed. Six rows empty the stimulus's factor — a perfectly neutral sample is the same colour for every observer, at any age and any field size — and two empty the observer's, since a gain on each cone and a change of basis are both absorbed exactly. All eight are identities rather than small numbers. The last two are the same two conditions imposed in a published cone space rather than in the observer's own, and they are worth eight and thirteen units: the identity is about the eye, and the arithmetic everybody uses is in somebody else's coordinates.

The conditions are the result

The round measured about twenty departures and established ten conditions. The departures are numbers that depend on a sample, a light and a construction; the conditions are exact, they hold under every substitution tried, and they are what a reader can act on. A size is a measurement and a condition is a mechanism.

limits · Limits
Which of the collection's published quantities a departure can be pushed through. The six quantities the previous round recomputed under six different colour-difference units, and whether the same treatment works for a departure. Two do: the adaptation census and the metameric pair both take reflectances and a light, which is what a departure acts on. Four do not, and the reasons are different in each case rather than a single obstacle. A unit is a function applied to the answers, so it can be swapped at the end of any computation; a departure changes the object at the start, so it has to be accepted by every stage in between. That is the practical difference between auditing a convention and auditing a structure.

What this round could not reach

Three audits, about twenty departures and ten conditions, and a longer list of things that were named and not measured. Every item on it is specific, most of them are an afternoon's work, and the reason none was done is the same in every case — the round ran out of round.

limits · Limits
What a slope limit costs the object-colour solid, direction by direction. For each transition width, how much of its ideal reach the solid keeps: the median direction, the tenth percentile, and the worst. At twenty nanometres the median keeps 0.997 and the tenth percentile 0.985; at eighty they keep 0.946 and 0.766, and at 160 0.826 and 0.417. The worst direction falls from 1.00 at five nanometres to 0.20 at 160, with directions reaching under five units beyond black set aside. The cost is in a corner only at widths sharper than an ordinary pigment's.

The limits assume a pigment that switches instantly

The hardest boundary in colorimetry is reached by reflectances that jump between nought and one at a wavelength, and no material does that. Constrain the jump to take twenty nanometres — a sharp dye — and the median direction of the object-colour solid loses under half a per cent of its reach. Constrain it to eighty, an ordinary pigment, and the median loses five per cent, the tenth percentile nearly a quarter, and seven directions in ten lose more than one. The cost is in a corner only for chemistry sharper than paint.

limits · Limits
How far CIECAM16 moves a monochromatic hue when the light is brightened thirtyfold. A monochromatic stimulus at a relative luminance of 2 and of 60, read through CIECAM16 in one room, and the difference between its two hue angles. The model was never fitted to this effect and has it anyway: the shift is positive at the short end, negative through the greens, positive again in the yellows and reds, and crosses zero at 459, 495, 502, 570 nanometres. The marks are the invariant wavelengths the literature reports — 474, 506, 571.

The model has a hue shift it was never given

A monochromatic light changes hue as it is brightened, except at three wavelengths that do not move — an effect measured since the nineteenth century and not among the things CIECAM16 was fitted to. The model has it anyway: brightening a stimulus thirtyfold moves its hue angle, and the places where the movement crosses zero land at 459, 495, 502 and 570 nanometres against the reported 474, 506 and 571. The sizes are another matter.

brain · Appearance
What the choice of adopted white is worth, in a room lit by two lights. A room lit half by daylight and half by an incandescent lamp. The light on the surfaces is fixed; what varies is the white the model is told the observer has adapted to, running from the lamp on the left to the window on the right. The median of twelve surfaces moves 32.6 CAM16-UCS units if the lamp is adopted and 24.5 if the window is, against the room's own mixture in the middle. The model offers no way to choose, and its degree of adaptation is 0.94 at every point of the dial.

A room with two lights has no white

An appearance model takes one adapting white. A desk beside a window has two, and the mixture falling on the paper is not the same thing as the white the person reading it has adapted to. Mixing the lights is arithmetic. Choosing the white is not, and the choice is worth sixty units of appearance — most of which is a cast, and not all of which is.

brain · Appearance
One grey scale, three backgrounds. CIECAM16's lightness against the luminance factor of a neutral sample, with only the background changed. A grey reflecting 19% reads 46.7 on a near-black background and 32.8 on a near-white one. The three curves are not three shapes: each is the same curve raised to a different power, because the background reaches lightness only through the exponent z, which runs 1.621 to 2.374 across the three.

A dark background moves every difference and no match

CIECAM16's background is one number, and it reaches lightness as one exponent. That is enough to change what a grey looks like and not enough to change which of two greys is lighter — so a match survives the background exactly, a corresponding colour is invariant to it, and a tolerance is not. The effect the background is usually invoked to explain is absent from the model entirely.

brain · Appearance
A crispening term puts the peak where the background is. How much lightness the model returns for a small change in the sample's level, against the sample's level measured as a log ratio to the background's — so that all three backgrounds share one axis and a peak at the background is a peak at zero. The pale curves are CIECAM16 as it stands, which has no peak anywhere: they rise slowly and monotonically because a background that enters as four constants fixed before the sample arrives cannot know where the sample sits relative to it. The solid curves are the same model with a term of amplitude 6 and width 0.5 added to lightness. Each peaks at zero to within 0.000 of a log unit, and the peak's height is 12.00 lightness units per log unit of level — the amplitude divided by the width, exactly.

The cancellation is exact and cheap to lose

CIECAM16 has no crispening, and adding one was expected to be expensive: the background's exactness in a corresponding colour comes from its being a common exponent, and a function of the sample's own level is not one. It is expensive in kind and not in size. A term that raises a straddling pair's lightness difference by half moves a corresponding colour by five thousandths of a tristimulus unit — a thousandth of what stating the background differently at the two ends already costs.

brain · Appearance
The pairs that change places in chroma are a wedge with two straight edges. Every pair of samples, plotted by the log ratio of the two samples' background-free responses across and the log ratio of their chroma at a background of 2 up. A pair changes places between that background and one of 80 exactly when its chroma ratio and its response ratio point in opposite directions and the chroma ratio is the smaller — which is the wedge between the horizontal axis and a line of slope -0.2598, half the change in the lightness exponent. 754 of 14028 pairs are inside it, and the condition names every one of them and nothing else: 0 disagreements between the line and the model. The pale dots are one pair in eleven of those outside; the filled ones are every pair inside.

The reversals have a straight edge

Twenty-one of 276 pairs change places in chroma between a dark background and a light one, and the reason given was that chroma is a product of a term carrying the exponent and a term that does not. That is true and it is not a description of which pairs. Chroma at one background is a single common factor times a power of lightness at another, so a pair reverses exactly when its chroma ratio and its lightness ratio point opposite ways and the first is the smaller — a wedge with two straight edges, which names every reversal and nothing else.

brain · Appearance
The glossiest finish the solver can report, against what it costs to report it. Six quadratures, each with the roughness at which its answer stops being stable, on logarithmic axes. The line is a fit and its slope is -0.350: the reachable roughness falls as the cost to the power of about a third, so reaching a finish twice as glossy costs about 7 times the work. The solver used here sits at 108 directions and reports down to a roughness of 0.145, which is where its own note put the boundary by inspection.

The boundary belongs to the quadrature

The directional solver stops at a roughness of about 0.15, and below that its answers are not imprecise but unphysical. The boundary is where the lobe stops being resolved by the sampling, so it belongs to the discretisation rather than to the room — and moving it is a purchase. Measured across six quadratures the reachable roughness falls as the cost to the power of a third, so a finish twice as glossy costs seven times the work and a polished varnish costs two hundred and thirty-six times.

scene · Scene
A 40-nanometre limit written in nanometres and written in energy. The transition width a reflectance is allowed, across the spectrum, for two ways of stating the same sharpness. Written in nanometres it is 40 everywhere. Written as a fixed spread of photon energy, which is how an absorption band's width is set, it is 40 at 550 nanometres and grows as the square of the wavelength: 21 at 400 and 67 at 700. The steps are the quantisation the calculation actually imposes.

A limit written in energy charges the reds

A slope limit on reflectance is usually written in nanometres and applied the same way across the spectrum. An absorption band's width is closer to a fixed spread of photon energy, which is nearly twice as many nanometres at 700 as at 500. Written that way, a limit that is forty nanometres at 550 is kinder to the object-colour solid overall — 489 of 913 directions lose a per cent rather than 544 — and it charges the reds more. Which directions pay is decided by one thing: whether their optimal edges fall above or below the reference wavelength.

limits · Limits
Two tables, two directions of error: 5-node ramps of four inks. For each ink, the mean signed lightness error between the nodes: of the ordinary forward table, which errs light, and of four ways to fill the inverse table, all of which err dark except the one refitted against its own objective. On cyan the forward table errs by +0.206; an inverse filled from the press by -0.317; one inverted from the ordinary table by -0.554, because it inherits the forward table's error on top of its own; one inverted from the refitted table by -0.367; and one refitted in its own right by -0.002.

The inverse table errs dark

A profile's forward table predicts a print lighter than the press makes, and refitting its nodes removes the bias. The table a colour engine actually uses to separate an image is the other one — the inverse, from colour to ink — and it errs the opposite way: filled exactly from the press it asks for too much ink and prints dark, and built by inverting the ordinary forward table it prints darker still. Inverting the refitted forward table removes the inherited part and leaves the inverse's own. The round trip through both tables improves only when each is refitted against its own error, and then the two are no longer each other's inverse.

applied · Delivery
What the rods cost a match, by where their signal enters and under which lamp. For five lights, the median colour difference over forty-two surfaces between the reference observer and the same observer with a rod signal a tenth of each cone's peak added — into all three cone channels, into the long- and middle-wavelength channels only, or into the short-wavelength channel only. Under daylight the first two are 1.03 and 0.90: whether the rods reach the S pathway hardly matters. Under a phosphor white LED they are 1.24 and 0.45, a factor of 2.75, and the S-only route alone costs 0.96.

The rods' route is priced by the lamp

A rod signal in a dim room disturbs a colour match, and how much depends on which of the cone pathways it reaches — a weight the physiology leaves uncertain, especially for the blue–yellow pathway. Under daylight the uncertainty is nearly free: a rod signal that skips the S pathway costs 0.90 at the median surface against 1.03 for one that enters all three. Under a phosphor white LED it is worth a factor of 2.75, 0.45 against 1.24. What decides it is one number per lamp: how large the rod signal is compared with each cone class's own catch of the light.

eye · Cones
How far each model turns a display colour's hue as white is added. The twenty-four most saturated colours an sRGB display makes, one every 15° of HSV hue across, each mixed with the display's white at the same luminance down to a fifth of its purity. Up, how far that mixture's hue angle turns in CIECAM16, CIELAB and Oklab. From red to a fifth of its purity CIECAM16 turns −9.4° and Oklab −10.2°; CIELAB −18.1°. From the display's blue, Oklab turns +16.3°, CIECAM16 +3.6° and CIELAB −8.9°.

White turns a hue, and the models part at blue

Mix a saturated light with white and its hue changes as well as its saturation — the Abney effect, and the reason lines of constant perceived hue curve in a chromaticity diagram. Asked what adding white does to the twenty-four most saturated colours a display makes, CIECAM16, CIELAB and Oklab all turn the hue. About reds they agree: CIECAM16 turns within a degree of Oklab, whose hue was fitted to observers' constant-hue judgements. About the display's blue they do not: Oklab turns sixteen degrees, CIECAM16 four, and CIELAB nine the other way.

brain · Appearance
Which two lamps to stand a mesopic match between. Every pair of the five lights, by how far a match made under one and set under the other moves as the rod signal's weight into the S channel goes from nothing to equal — the median over forty-two surfaces, which is the signal an experiment has to resolve. The best pair is daylight against phosphor LED at 0.58 ΔE₀₀; the worst is tungsten against fluorescent tube at 0.09, a factor of 6. The count at the right is how many settings it takes to resolve the weight to a tenth at half a colour difference of scatter per setting.

The reference lamp must not move

To measure an uncertain weight, use the condition in which the answer depends on it most. That is right about half of an asymmetric colour match and exactly wrong about the other half: a match measures a difference of two displacements, and a reference field that also moves with the weight cancels the signal the test field carries. Daylight is the least sensitive of five lamps and belongs in every one of the three best pairs — 75 settings against a phosphor LED, 2,804 against the pair of lamps the principle as stated would have chosen.

eye · Cones
Two ways to ask how much rod signal an older eye has. The rod signal's catch of each lamp divided by the S cones' own catch, against the observer's age, for five lamps — drawn twice. The upper curves take the rod signal at a fixed absolute size, and every one of them roughly doubles from twenty to seventy-five: an older lens cuts the blue before the S cones see it and the rods, peaking further into the green, lose much less. The lower curves take the rod signal at a tenth of each cone's own peak absorptance, which is the model's own definition, and they barely move at all. Nothing about the retina differs between the two; only the normalisation does.

A rod signal has no natural size

An older lens absorbs where the S cones are sensitive, so it should make the uncertain rod-to-S-cone weight cheaper. Measured, the rod signal's catch of a phosphor LED as a share of the S cones' own catch more than doubles from twenty to seventy-five — and the share the model actually uses falls by a fifth. The two differ by the S cone's peak absorptance, which the lens takes 60 per cent of, and which entered the model as a normalisation rather than as a claim.

eye · Cones
How far a mesopic match moves as the S weight opens: two rooms against one field. For every pair of the five lamps, the median over forty-two surfaces of how far a match moves as the rod signal's weight into the S channel goes from nothing to equal: pale for the two-room match, each half adapted to its own lamp; dark for a bipartite field whose two halves share one adaptation. The field's signal is larger for every pair, by ×1.5 to ×7.7.

One field keeps what two rooms divide out

An asymmetric match can measure how strongly the rods feed the blue-yellow pathway, but set with the observer adapted to each lamp in turn it needs seventy-five settings on the best pair of lamps and hours of waiting between them. Putting the two lamps on the two halves of one field was proposed as the quick version, at the cost of a weaker signal. The signal is not weaker. Under one shared adaptation it is three times stronger for daylight against a white LED, and the best pair needs six settings. The adaptation that makes the slow version slow is also what was dividing the rods' contribution out of each half.

eye · Cones
The same lamps, charged by two kinds of slow pigment. Each lamp — the three emitters, a fourth band at seven positions, and the cheapest symmetric and lopsided bands rendering at 88 — as its fidelity index against the directions of the solid a slow pigment loses more than a per cent of its reach in, for a forty-nanometre slope limit (open) and for three absorption bands none narrower than forty nanometres (filled), joined by a line. Every line runs leftward: the band-shape pigment loses fewer directions under every lamp, and the lamps rendering best gain the most. At 88 the slope limit loses 50 and the band-shape pigment 33.

The pigment decides the trade, not the band

A four-emitter lamp that renders well costs a slow pigment part of its reach, and reshaping the fourth band barely changes that. Changing the pigment changes it a great deal. Modelled as three absorption bands none narrower than forty nanometres, rather than as a forty-nanometre slope limit, a slow pigment loses a third fewer of the solid's directions under the best-rendering lamp, and the price of going from the three-emitter lamp to a fidelity of 88 halves. The lopsided band that helped a slope-limited pigment does nothing at all for this one. And at 590 nanometres a fourth band renders at 86 almost for free.

limits · Limits
Every lamp, charged by a slope limit and by bands in nanometres and in energy. For each lamp, ordered by fidelity index, the directions of the solid lost by a forty-nanometre slope limit, by three absorption bands none narrower than forty nanometres, and by three none narrower than 0.158 electronvolts. The energy convention loses fewest under every lamp: 20 against 23 and 31 under the three emitters, and 26 against 33 and 51 under the best-rendering lamp.

Written in energy, the bands spare the green

A slow pigment modelled as absorption bands pays half what a slope limit pays for a four-emitter lamp's rendering, and a fourth band at 590 nanometres costs it almost nothing. That result assumed every band is at least forty nanometres wide, and a real absorption band has a width in energy, not in nanometres. Written that way it is narrower in the blue and wider in the red, and the fear was that the red would take back the amber. It does not. The band limit written in energy loses fewer directions under every lamp, the fourth band at 590 still costs six, and the price of rendering at 88 falls from ten directions to six — because the directions it wins back are green, not amber.

limits · Limits
CIECAM16's colourfulness loss by hue, with each suspect removed. The share of colourfulness each of the twenty-four most saturated sRGB colours loses when white of 25 per cent of its luminance is added, all at the same luminance, in CIECAM16 as published, with its eccentricity factor held at one, and with its cone-signal denominator replaced by its achromatic signal; CIELAB chroma for reference. The blue at 240 degrees loses 1.7 per cent as published and 1.6 with the hue factor removed, and 5.4 with the denominator replaced — the curve then lies close to CIELAB's.

The blue resists through the model's denominator

CIECAM16 says a saturated blue is nearly impervious to added white: at equal luminance and an equal dose it loses a sixteenth of what an orange loses, where CIELAB and Oklab say a quarter. The model has two obvious places for that to come from — a hue factor fitted to make colourfulness equal across hues, and the sum of cone signals it divides its opponent signals by. Setting the hue factor to one changes nothing. Replacing the sum with the model's own achromatic signal makes the blue lose 0.233 of the orange's loss, beside CIELAB's 0.221 and Oklab's 0.223. The disagreement is one denominator.

brain · Appearance
What the classifier misses, against what the camera gets wrong. Every lamp as the pair of channels reads it against the camera's mean colour error under it, with its two-matrix profile blended at the lamp's colour temperature. The band is the range of the six smooth census lamps, 1.14 to 1.62. Left of the line the classifier calls a lamp smooth; no lamp there is above the band. The violet-pumped LEDs it misses leave the camera at least as accurate as a smooth lamp does, two of them more so.

The lamps two channels miss are smooth to the camera

A narrow channel at 450 nm tells a phone which lamps are structured, and a white LED pumped in the violet might hide from it; a channel at 500 nm does the same job, and an LED with a cyan emitter should blind it. Reading both and calling a lamp structured if either departs was supposed to cover both families. It covers the cyan family only because the 450 nm channel already did, and half the violet-pumped LEDs escape both channels. Every one that escapes leaves the camera's colours as accurate as a smooth lamp does. What the classifier misses is what the camera does not need to be warned about.

imaging · Capture
The camera's error, and the two-channel estimate of it. Each of the fifty-four lamps as the camera's true mean colour error against the estimate from the 450 and 500 nm channels, fitted with that lamp left out. The held-out error is ±0.14 ΔE00 against ±0.16 from the 450 nm channel alone and ±0.30 from the mean. The dashed lines at 1.5 mark the repair decision: points right of the vertical and below the horizontal are lamps that need a repair and are not given one.

Two channels estimate what one can only sort

A narrow sensor channel was fitted to call lamps smooth or structured, and the label turned out to be a proxy for the thing a camera cares about: its own colour error under the lamp. Scored against that error directly, the best channel is still the one at 450 nm — the band where camera and observer differ most comes close and no closer. Read as an estimate rather than a verdict, a second channel at 500 nm, useless as a vote, earns its place: together they predict the camera's error to within 0.14 ΔE00 over fifty-four lamps, and deciding when to repair from that estimate raises a quarter of the false alarms the label raises.

imaging · Capture
How far white turns each display colour's hue, in CIECAM16 and with its cone space changed. The twenty-four most saturated sRGB colours, each mixed with white of the same luminance down to a fifth of its purity, and the turn of its hue angle in Oklab, in CIECAM16, in CIECAM16 with its compression done in the Hunt–Pointer–Estévez space rather than CAT16's, and in CIECAM02's front end. At the display's blue Oklab turns 16.3 degrees and CIECAM16 3.6; compressed in Hunt–Pointer–Estévez it turns 15.6, and CIECAM02 16.1. Over all twenty-four the two lie 3.2 and 3.2 degrees from Oklab, root mean square, against CIECAM16's 5.3.

The blue's hue turn was lost with a matrix

Add white to a saturated blue and its hue turns — sixteen degrees by the constant-hue data Oklab was fitted to, four by CIECAM16. The obvious suspect was the model's compressive response, acting on a very large blue signal. It is not: removing the compression's saturation moves no hue by half a degree, and a cube root instead of its exponent moves the blue by one. What decides it is the cone space the compression happens in. Computed in Hunt–Pointer–Estévez, the space CIECAM02 compressed in, the same model turns the blue 15.6 degrees; CIECAM02's own front end turns it 16.1. CIECAM16 merged CIECAM02's two spaces into one sharpened for adaptation, and that one gives a display's blue almost as much long-wave signal as white has.

brain · Appearance
What straightening the 570 nm channel buys an estimate of the camera's error. The root-mean-square and worst held-out errors of linear estimates of the camera's error, over fifty-four lamps with the three-emitter source kept in: from the 570 nm channel as read and through three transforms, from 450 nm alone, and from 450 nm with a log-transformed 570 nm channel or with 500 nm. Every transform rescues 570 nm from worse than the mean; none reaches 450 nm; and beside 450 nm it adds nothing, where 500 nm does.

A straightened channel repeats the one beside it

A phone's narrow sensor channel at 570 nm ranks a camera's colour error under a lamp almost as well as the one at 450, and estimates it worse than guessing the mean, because one lamp reads ten times higher than any other. Read through a logarithm, the channel is rescued: its estimate improves from ±0.57 to ±0.23. It still does not reach the 450 nm channel's ±0.16, and put beside that channel it adds nothing at all, where a 500 nm channel cuts the error to ±0.14. Straightened, 570 nm sorts the lamps as 450 nm already does; and the two lamps it reads highest have the most different errors, which no transform of one reading can tell apart.

imaging · Capture
Which way each narrow channel departs from what the camera predicts. Each lamp's two narrow channels, their departures from the camera's prediction kept signed. 37 of the fifty-four lamps, every structured one among them, lie in the lower right: more light than predicted at 450 nm, less at 500 — a peak and a trough. 8 lie in the upper left, the opposite pattern, most of them violet-pumped LEDs whose pump misses 450 nm. In both the departure of the two readings' ratio is the sum of the two distances. The 7 in the upper right are the most heavily cyan-filled LEDs, whose fill puts light at 500 nm, and two daylights near the origin.

One ratio reads a peak and a trough

Two narrow sensor channels, at 450 and 500 nm, estimate a camera's colour error under a lamp to ±0.14 ΔE₀₀; the proposal was to read their ratio as one number instead. Taken as one channel's departure over the other's, the ratio is worthless — no better than the mean, because for smooth lamps both departures are nearly nothing. Taken as the departure of the two readings' ratio from what the camera predicts for it, one number estimates the error to ±0.141, as well as the two channels as two. The reason is a sign: under every structured lamp the channels depart in opposite directions, a peak at 450 and a trough at 500, and the ratio adds them; where a cyan fill lifts 500, it subtracts them, as the error falls. And no five per cent calibration error moves any of these estimates by a hundredth.

imaging · Capture
Directions each pigment model loses, under three broadband lamps and a lamp of lines. For each lamp, how many directions of the object-colour solid a pigment model cannot reach within one per cent of the ideal: a slope limit, absorption bands no narrower than forty nanometres, and bands whose minimum width is fixed in energy. The order is the same under every lamp. The broadband lamps cost every model far more than the three narrow emitters: under daylight 89, 73 and 70 against 31, 23 and 20.

The lamp outweighs the pigment model

Three models of what a real colorant can do — a slope limit, absorption bands forty nanometres wide, and bands whose width is fixed in energy — were ranked under lamps of narrow emitters, slope dearest and energy cheapest. Under daylight, tungsten and a white LED the ranking holds, every time. What changes is everything else: each model loses two and a half to three and a half times as many directions of the object-colour solid under a broadband lamp as under three narrow emitters, and the difference between the models is smaller than the difference between the lamps. Under tungsten, whose power rises smoothly to the red, the three models are nearly one.

limits · Limits
Wings raise the width a table declares, and it follows the line's half maximum. The width the tube's table declares for itself at half a per cent — the narrowest width any of its peaks admits — as every mercury line is given Lorentzian wings from nothing to half its core's width, through one and two nanometre slits, beside the Voigt line's own full width at half maximum. With no wings both slits declare under 1.2 nm; with wings a quarter of the core's, 1.36 through 1 nm and 1.41 through 2 nm, against a half-maximum width of 1.37. Through one nanometre the table declares nothing at the widest wings: every line is refused.

A line's wings widen the width a table declares

A narrow table declares its lamp's narrowest line width by fitting each peak with a Gaussian, and the worry was a line whose profile is not Gaussian: a mercury line broadened by collisions has Lorentzian wings on its core, every line shares them, and a Gaussian fit can only take the wings in by widening. It does. With wings a quarter of the core's width, the table declares 1.36 nm for a 1.2 nm core — close to the winged line's own half-maximum width, 1.37. The prediction called that the unsafe direction. It is not: the ceiling and the variance the earlier bound builds on the declared width never fall below the winged lamp's own, because through a slit a winged line behaves like the wider line the table says it is.

light · Light
Divide the faces and the tall room gains colour from a grey finish. How many of the census's 72 paints a satin finish on the grey faces makes more colourful, with every face divided into one to six patches a side. One patch a face is the census, where the tall room with its side walls painted gains for 0; from one to six patches a side it gains for 0, 4, 8, 11, 15, 15. The tall narrow slot, painted the same way, goes 22, 7, 11, 45, 72, 72, and the tall room with all four walls painted barely moves.

The tall room gains once its walls are divided

The room census solves each face as one patch, and it says a satin finish on the grey faces of a tall room with painted side walls makes the room more colourful for none of seventy-two paints. The true box disagreed: rays from points on the grey end walls said the finish sends the lamp's light towards the paint. Dividing every face into patches settles it. The end wall's upper patches, which see the lamp at a grazing slant, send its light across to the painted walls; its lower patches send it to the floor. The room gains for 0, 4, 8, 11, 15 and 15 paints as the faces are divided one to six times a side — the light, broad paints — and the narrow slot beside it goes from 22 to all 72.

scene · Scene
More rods make a lens band's pull on the rod weight worse, unless the band is fitted. A sixty-year-old's lens with a band of a tenth of a density at 450 nm, fitted by the model with the rod signal a tenth to a half of each cone's peak: the shift in the fitted rod weight, in its own standard errors. With weight, lens age and macula fitted, one session's shift grows from +1.73 at a tenth to +2.53 at a third, and two sessions' more. With the band's amplitude fitted as a fourth number, one session stays under half a standard error at every share.

A dimmer session hides a lens band in the rods

A band of extra absorption in an older lens is read by a colour-matching session as lens age or as macular pigment, and it pulls the fitted rod weight with it. The rods see the lens and not the macula, so a dimmer session, where they carry a third of the signal instead of a tenth, was predicted to tell the band from the macula. It does the opposite. With the band at 450 nm left out of the fit, the rod weight's shift grows from 1.7 of its standard errors to 2.5, the misfit a session could notice shrinks by a third, and the macula and the band trade more tightly. The rods see the band — and the rod weight, which the fit is free to move, is exactly what absorbs it. What separates the band from the macula is fitting its amplitude as a fourth number, which works in daylight already.

eye · Cones
The painted census's counts with one patch a face and with the faces divided. For each of the thirty rooms — six boxes, each painted five ways — how many of 72 paints a satin finish on the grey faces makes more colourful with one patch a face, as the census solved it, and with every face divided five times a side (six for the two tall boxes). 12 counts do not move; 9 move by twenty paints or more, shaded — darker where the divided room gains more. Some paint gains in 28 rooms both ways, and every paint in 13 with one patch and 17 divided.

Divided faces keep the census's count and lose its rule

The painted-room census, solved with one patch a face, found that a satin finish on a room's grey faces adds colour in 28 of 30 rooms, and a later essay found one geometric number whose sign sorted which rooms gain. Re-solved with every face divided into twenty-five or thirty-six patches, the count survives exactly — 28 rooms, though two of them trade places — and the finish colours every paint in 17 rooms instead of 13. The rule does not: the send number, now matching the true box's own to a rank correlation of 0.96, orders the divided counts at 0.63, and rooms on the wrong side of its zero gain for every paint. Nine of the thirty counts move by twenty paints or more.

scene · Scene
A triphosphor tube costs a slow pigment what three emitters do; a halophosphate tube what daylight does. For each lamp, the share of the object-colour solid's directions a pigment model cannot reach within one per cent of the ideal — a slope limit, absorption bands no narrower than forty nanometres, and bands whose width is fixed in energy — with the count on each bar. Under the triphosphor tube the band model loses 26 of 154, beside the emitters' 23; under daylight 73 of 154, and under the halophosphate tube 71. The tube's coating alone loses fewer than the tube; its mercury lines, doubled, more.

A tube spares a pigment through its phosphors

Three models of a real pigment lose two and a half to three and a half times as many directions of the object-colour solid under daylight as under three narrow emitters. A fluorescent tube is both kinds of lamp — narrow mercury lines on phosphor bands — and the prediction was that its bands would light the gaps between its lines and put it two thirds of the way to daylight. A triphosphor tube sits with the emitters instead: 26 directions lost to forty-nanometre bands, against the emitters' 23 and daylight's 73. The credit is its phosphors'. Its coating alone, lines taken out, loses fewer still; its mercury lines cost directions whose edges sit in the gaps between the phosphors, and doubled they cost more. A halophosphate tube, the same lines on two broad bands, costs what daylight costs at the same rendering index.

limits · Limits
How well a matching session places a lens band's centre. A sixty-year-old's lens with a band of a tenth of a density centred from 410 to 460 nm, fitted with the rod weight, lens age, macula, the band's amplitude and its centre all free: the centre's standard error, from one daylight-against-LED session and from designs adding a second session. One session places the centre to 11.5 nm at worst below 430 and within 5.7 above it; adding the LED against the three-emitter lamp brings every centre within 5.5.

A second lamp pair finds a lens band's centre

A band of extra absorption in an older lens is found by a colour-matching fit only if the fit has a parameter for it, and a band parameter at a fixed wavelength finds only a band near that wavelength. Freeing the band's centre as a fifth number asks whether the matches can place it. From one daylight-against-LED session they place a band above 430 nm to within six nanometres and one below it only to eight to twelve, where moving the band and ageing the lens change the matches together — and there they barely see the band at all. A second session, the LED against a three-emitter lamp, places every centre within five and a half nanometres. The fluorescent tube's line at 436 nm helps where it sits and nowhere else.

eye · Cones
From which starts a fit finds a lens band, two sessions. For a band of a tenth of a density at 415, 430 and 445 nm in a sixty-year-old's lens, the number of twenty simulated experiments of two sessions each in which a fit of all five numbers, started with the band's centre at each of 400 to 470 nm, finds the centre within twice its standard error. The ticks at the left edge are the same count for a fit started at the true observer: 18, 18, 18 for the three bands.

A lost lens band goes to age or the macula

Two colour-matching sessions determine the centre of a band of extra absorption in an older lens to about five nanometres, if a fit can find it. Fitted in full from eight starts across 400 to 470 nm on twenty simulated experiments, two sessions find a band at 415, 430 or 445 nm from every start in fifteen to eighteen experiments of twenty, against eighteen for a fit started at the truth. The prediction was that a low band would be lost from high starts to the macula's flank. The start barely matters with two sessions, and a lost band does go somewhere — but a band at 415 or 430 goes to lens age, three to five years of it, and only a band at 445 goes to the macula. Every loss is a worse fit than the session's best, so eight starts find the band as often as the truth does. With one session the start decides.

eye · Cones
Where the ceiling on a self-absorbed line holds, and where it does not. In the windows within four nanometres of the 546 nm line, the smallest ratio of the ceiling the tables put on a window's peak to the absorbed line's true peak, built on the narrowest width the table admits for the line and on the emitted 1.2 nm, through each slit. On the admitted width the ceiling holds to a depth of three and falls below the peak at 3.5 (×0.981) and 4 (×0.885) through two nanometres. On 1.2 nm it holds through two nanometres at every depth.

A reversed line is read as one line

A strong mercury line in a dense discharge absorbs its own centre on the way out: at an optical depth of one its top is flat, and beyond that it dips, until at four the line is two humps with a trough eighty per cent deep between them. The prediction was that a one-nanometre table refuses such a line from a depth of about one and a two-nanometre table reads it as a Gaussian about the width of its flat top, safely. Both hold, and the second only up to a point. A two-nanometre table admits the line at every depth to four, and from three and a half the width it admits is too wide for the humps: the ceiling built on it falls eleven per cent below the line's true peak. The only line that could make a declared width unsafe was one narrower at its peak than its entries suggest — and a reversed line is exactly that.

light · Light
How many directions each lamp costs a slow pigment, counted at three depths. For nine lamps, the share of the object-colour solid's directions in which a slope-limited pigment falls short of the ideal pigment's reach by more than one, three and five per cent. The broadband lamps' counts fall three- to eightfold from one per cent to five, and the emitters' and the triphosphor tubes' as much or more; the clear mercury lamp's falls least, from 14 per cent to 7, and at five per cent it costs more than the emitters' 3 and the tube's 2.

A mercury lamp's few losses are deep

Every census of what a slow pigment can reach has counted the directions of the object-colour solid it misses by more than one per cent, and by that count a clear mercury lamp — four visible lines and nothing else — spares a pigment as well as three narrow emitters do. Read for depth, it is the one lamp of nine whose losses do not fall away: half of what a slope-limited pigment loses under it, it loses by more than five per cent, and its mean shortfall is half as large again as under the emitters or a triphosphor tube. Every one of those losses is the same kind of colour: one that reflects the mercury's green line at 546 nm and absorbs its yellow line at 578, or the reverse, 32 nm apart. The dark-share rule that ordered the counts orders the depths less well.

limits · Limits
Counting the paint's light instead of the lamp's orders the rooms not at all. The thirty rooms of the painted census on divided faces, each placed twice: by the send number weighted by the paint's own light arriving at the grey faces, and by the send number weighted by the lamp's light, against how many of 72 paints a grey finish colours. The lamp-lit number ranks the wall and floor rooms at 0.63; the paint-lit one at -0.07, and over all thirty at -0.02.

The paint's own light does not order the rooms

A satin finish on a room's grey faces colours some paint in 28 of the painted census's 30 rooms, and the number meant to say which rooms gain most — how much of the lamp's light the finish sends to the paint — orders the rooms solved on divided faces at only 0.63. The rooms it misplaced return mostly the paint's own light, so the proposal was to count that instead. Counted, the paint's light orders the rooms at −0.07. In every room with its floor painted the finish sends the floor's light away from the floor, and every paint gains; with the ceiling painted the paint is the lamp and the two numbers are the same number. Even the room's own response, read off the solve with the paint in place, orders the counts only at 0.71. The census has to be solved room by room.

scene · Scene
The census read on the whole room and on the painted faces. For the thirty rooms on divided faces, how many of 72 paints a satin finish on the grey faces makes more colourful, read as the census reads it — every face's light together — and read on the painted faces alone. Read on the room, 11 rooms sit part-way; read on the paint, 28 rooms gain for all 72 and 2 for none, and no room sits between.

The paint itself gains all or nothing

The painted census counts how many of seventy-two paints a satin finish on a room's grey faces makes more colourful, reading the room's colour as all of its light, and eleven of its thirty rooms sit part-way. Read on the painted faces alone — the light a viewer looking at the paint receives — no room sits part-way: twenty-eight gain for every paint and two for none. The change on the paint is never more than a per cent and a half, where the room's reading swings from −18 to +57 per cent, so the census's middle ground was the grey faces all along. A box with its floor painted and the same box with its ceiling painted gain the same colour to a hundredth of a point while the light they gain differs by up to eighty-two points; neither send number orders the size of the gain, and the paint's own brightness does.

scene · Scene
Where a two-nanometre table's ceiling on a notched line fails. In the windows within four nanometres of the 546 nm line, the ceiling built on the narrowest width a two-nanometre table admits for the line, as a multiple of the absorbed line's true peak, behind columns a whole, a half and a third as wide as the line. The uniform column's ceiling crosses below one at a depth of 3.42 and ends where the table refuses the line; the half and third columns' cross at 2.34 and 2.35 and are never refused, falling to ×0.73 and ×0.80 at a depth of five.

A notch in a line is never refused

A dense discharge's green mercury line loses its centre to the atoms between the glow and the tube wall, and those atoms are cooler than the glow, so their absorption is narrower than the line it cuts. With the absorbing layer half or a third as wide as the line, a one-nanometre table still refuses the line from an optical depth of one, exactly where it refused the broad dip. A two-nanometre table never refuses it at all: to a depth of five, with ninety-eight per cent of the centre gone, one Gaussian fits its entries within a seventh of a per cent. And the ceiling built on the width it reads fails from a depth of about two and a third — a whole unit sooner than behind a column as wide as the line — and never recovers, falling to three quarters of the true peak.

light · Light
Three family lines through the departures, and whom they claim. Every lamp of the census and the halophosphate tube's four siblings by its 450 and 640 nm departures, coloured by family, with the principal line of each family that has three or more members — the radiators, the white LEDs and the halophosphate tubes — solid over the stretch its members span and dashed beyond. Circled are the 29 lamps whose nearest line is another family's. The radiators' short line runs along the LEDs' long one and, extended, through the violet-pumped LEDs.

A family's line runs through its neighbours

The halophosphate tubes differ from one another by one number — where their main phosphor band sits — and so lie along a line in the three departures an ambient-light sensor reads. The proposal was to classify a lamp by the family whose line passes nearest, which would keep the tube a vote of neighbours gives up. It keeps the tube, under every version that does not rescale the distances. It also places eighteen white LEDs on the radiators' line, because that line — fitted to six radiators close together — runs along the LEDs' own and, extended, straight through the violet-pumped ones; and the radiators' estimate, extrapolated to them, misses the triphosphor tube by 7.6. Clamped to the stretch each family spans, the lines still cost ±0.285; given to the halophosphate family alone, its line claims a cyan LED and costs ±0.179. The one line classifier that comes in under the ratio line's ±0.141 does so by two thousandths, having placed the tube with the LEDs.

imaging · Capture
How sharp each corner of two displays is, in CIELAB and in ΔE₀₀. For the three primaries and three secondaries of sRGB and BT.2020, the move per unit of margin that a perfect corner of each one's tangent shape makes in CIELAB and carried into ΔE₀₀ by its full local matrix. The blue is ×3.35 and ×3.17 in CIELAB, against the press's blue at ×1.25; in ΔE₀₀ it is ×1.42 and ×1.26. ΔE₀₀ brings every corner of both displays under ×1.9.

A display's blue is sharp where the rotation is not

ΔE₀₀'s rotation term shears chroma into hue near a CIELAB hue of 275 degrees, and at a press's blue corner it had nothing to act on because the corner was blunt. The prediction was that a display's blue — an additive primary — would be a sharp corner, and that there the rotation would change how far a safety margin moves it by more than a tenth. The first half holds: sRGB's blue moves 3.35 times a CIELAB margin and BT.2020's 3.17, against the press's 1.25, and insetting the curved gamut directly confirms it to the second decimal. The second half fails, twice. A display's blue sits at 306 degrees, thirty past the rotation's centre, where the term grips a quarter as hard; and ΔE₀₀ blunts the corner to 1.42 by compressing its chroma sevenfold. Along the edge from blue to cyan the hue does pass through 275 and the grip reaches −0.87 — where the edge is nearly a face. Nowhere near either display's blue does the rotation move a prediction by four hundredths.

matching · Gamut
What adaptation cannot remove from an orange tint, with and without a thin dot edge. For a reader fully adapted to brightened office paper, the orange tint's hue turn against its solid beyond what a non-fluorescent sheet of the same colour leaves, at coverages from five to sixty per cent, with a uniform ink film and with rims of three, six and twelve micrometres. The residue is largest at the palest tint for every rim, and every wider rim raises it: at a fifth coverage from 6.8° to 7.9°.

A thin dot edge lets the glow back in

A pale tint printed on brightened paper keeps part of its hue turn however fully a reader adapts to the sheet — ten degrees for a fifth-coverage orange where a non-fluorescent sheet of the same colour leaves three — because the ink's vehicle puts out the brightener's glow under the solid and the tint's bare paper keeps it. That census gave every dot a uniform film. A real dot thins at its edge, a thin film lets ultraviolet through, and at the pale end of a ramp most of a dot is edge. The prediction was that the edge would restore the glow under the tint's dots, shrink the residue by a third at a fifth coverage and move the worst of it to the mid-tones. The edge does restore the glow — nine times as much under a small dot with a twelve-micrometre rim. And the residue grows: 6.8 degrees to 7.9 at a fifth coverage, 7.2 to 9.0 at a twentieth. The residue is the tint glowing where the solid does not, and more glow under the tint's dots is more of the difference. The palest tint keeps the most, with or without an edge.

brain · Appearance
The best band pigment for a direction that splits the green from the yellow. Under the clear mercury lamp, the direction of the object-colour solid with the pattern −−+− over the 405, 436, 546 and 578 nm lines that the three-band pigment reaches least well, searched from 680 starts: its reflectance, 5.4 per cent short of the ideal, with bands at 607 nm, 427 nm, 607 nm; and with a fourth band, 4.3 per cent short. The fall between the green line and the yellow is made by stacking bands on one side of it, never by a narrow peak between two.

A pair of lines asks for a cliff, not a gap

Under a clear mercury lamp, every direction of colour a slow pigment loses by more than five per cent asks it to reflect one of the lamp's green and yellow lines, 32 nanometres apart, and absorb the other. The prediction was that a pigment of two absorption bands with a narrow gap between them — a peak no single transition can make — would recover those deep losses. No direction asks for a peak. The lamp's four lines leave only one transition within a hundred nanometres of another, so what a splitting direction needs is a cliff: one flank falling from reflecting to absorbing in the twenty-five nanometres between the green line's last strong sample and the yellow's first. One band at the census's depth takes 27.8 to fall that far; two stacked at one centre take 24.9. Searched from 680 starts, the census's own band model does exactly that — stacks its bands on one side of the pair — and reaches further than the census found in seventeen directions of twenty-five. What stays deep spends a band on the blue.

limits · Limits
Where a reversed tube's table declares a width its ceiling cannot stand on. With every mercury line behind its own column, in proportion to its strength, the ceiling built on the width the whole table declares — the narrowest any of its peaks admits — as a multiple of the reversed lamp's true peak in the worst window, through one and two nanometres behind columns as wide as the lines and half as wide. The one-nanometre lines stop where the table refuses every peak and declares nothing. Through two nanometres behind the cooler column the table never stops declaring, and its declaration is unsafe from a depth of two and a half, falling to ×0.69.

A reversed tube declares from its least reversed line

A spectral table declares its lamp's line width as the narrowest width any of its peaks admits, and that declaration survived every reversed line so far because the tube's other lines were left unreversed to set it. A real discharge reverses its strong lines together. With every mercury line behind its own column, in proportion to its strength, the prediction was that a one-nanometre table would refuse every strong line and declare from the weak violet line, and a two-nanometre table would declare an unsafe width from a green-line depth of two and a half. The violet line is never read as a peak at all. The yellow line, the least reversed of the three that are, sets the declaration at every depth and widens it as it reverses. Through one nanometre the table refuses the blue and green lines and goes on declaring from the yellow — unsafely, in the violet's window, the one line the table never checked. Through two nanometres behind a cooler layer it refuses nothing, and from two and a half its declaration fails in the blue line's window, down to seven tenths of the true peak.

light · Light
What treating radiators and LEDs as one family does to the estimate. Held-out error over the census's fifty-four lamps for the ratio line alone, for the two-stage estimate with the separate families found by the nearest lamp and given, and with radiators and LEDs merged into one family of smooth sources, found by the nearest lamp, with the halophosphate tube's miss. Merged, the estimate comes to ±0.127 — below the ratio's ±0.141 and below the separate families even when every lamp's family is given — and keeps the tube.

Radiators and LEDs are one family to the sensor

An ambient-light sensor's three narrow departures see the collection's six smooth radiators and forty-four white LEDs along one line: the radiators' own short line lies on the LEDs' long one. Estimating a camera's colour error family by family, the census had treated them as two, and every classifier that tried to tell them apart paid for it. Merged into one family of smooth broadband sources, found by the nearest other lamp as before, the two-stage estimate comes to ±0.127 over fifty-four lamps held out — below the ratio line's ±0.141, and below the ±0.133 the separate families managed when every lamp's family was simply given. The halophosphate tube is still caught. The radiators, which the prediction said the merge would cost a little, are estimated better inside it than inside their own family, because a three-coefficient line fitted over five radiators was worse for them than the census-wide ratio line.

imaging · Capture
What ΔE₀₀'s chroma length alone does to each corner of two displays. For the six corners of sRGB and BT.2020, the move per unit of margin their tangent shapes predict in CIELAB, with ΔE₀₀'s chroma length alone, and with its lengths along lightness, chroma and hue together. The chroma length alone brings every corner but the yellow under ×1.35; it leaves the yellow at ×1.78 and ×1.80, and the full metric at ×1.75 and ×1.78.

The yellow is sharp where the tolerance unit does not compress

A safety margin moves each corner of a display's gamut inward by a multiple of itself that depends on the corner's shape. In CIELAB, sRGB's blue is its sharpest corner and its yellow among its bluntest; carried into ΔE₀₀, the order turns over, and the yellow becomes the sharpest corner of both sRGB and BT.2020. The prediction was that the yellow keeps its sharpness because its faces run along lightness, where ΔE₀₀'s weighting is largest at the yellow's L* of 97. Taking ΔE₀₀ apart length by length says otherwise. Its lightness weighting changes the yellow's move by nothing. Its chroma compression — the term that opens every other corner — does, on its own, bring every other corner of both displays under 1.35 times a margin, and leaves the yellow at 1.78. Of the yellow's three directions only one runs along chroma; at the other corners two or three do, and a metric that compresses chroma pulls those together and flattens the corner between them.

matching · Gamut
How sharp each corner of two displays is, in three units. For the six corners of sRGB and BT.2020, the move per unit of margin that a perfect corner of each one's tangent shape makes in CIELAB, in ΔE₀₀ and in CAM16-UCS at the display's white, 64 cd/m² and an average surround. CAM16-UCS keeps the yellow the sharpest corner of both displays, at ×1.66 and ×1.66, and blunts the blue — the sharpest corner of sRGB in CIELAB — to ×1.17 and ×1.10, the bluntest of all twelve.

An appearance model flattens the blue by its hue

A safety margin moves a corner of a display's gamut inward by a multiple of itself set by the corner's shape, and the unit the margin is written in decides the shape. In ΔE₀₀ the yellow is the sharpest corner of an sRGB and a BT.2020 display, because its sharpness lies across hue where ΔE₀₀'s chroma compression cannot reach it. CAM16-UCS compresses colourfulness less steeply, and the prediction was that it would leave the blue sharper than the yellow. It leaves the yellow sharpest, at 1.66 times a margin on both displays, and flattens the blue to 1.17 and 1.10 — the bluntest corner of all twelve. Its colourfulness does what the prediction said: on its own it would sharpen the blue past the yellow. Its hue scale undoes that. At a display's blue one degree of CIELAB hue is three and a half degrees of the appearance model's, and a unit that counts hue that finely there spreads the blue's directions apart until the corner is nearly a face.

matching · Gamut
How sharp each corner of two displays is, in four units. For the six corners of sRGB and BT.2020, the move per unit of margin that each corner's tangent shape predicts in CIELAB, ΔE₀₀, CAM16-UCS and ΔEITP, the last with the white at 320 cd/m². ΔEITP keeps the blue the sharpest corner of both displays, at ×3.12 and ×3.24, where CAM16-UCS makes it the bluntest at ×1.17 and ×1.10. At the green, cyan, magenta and yellow the three tolerance units agree within a quarter.

A quantiser keeps the blue a spike

A gamut margin moves a display's corners inward by multiples set by the unit it is written in. ΔE₀₀ and CAM16-UCS both blunt an sRGB or BT.2020 display's blue, CAM16-UCS to nearly a face, and the prediction was that ΔEITP — the difference built on ICtCp for high-dynamic-range television — would blunt it too. It does the opposite. With the white at 320 cd/m² the blue is ΔEITP's sharpest corner on both displays, moving 3.12 and 3.24 times a margin, about as far as in CIELAB; at the green, cyan, magenta and yellow the three tolerance units agree within a quarter, and at the blue they span a factor of three. ΔEITP's lengths alone would blunt the blue as ΔE₀₀ does. What keeps it sharp is the perceptual quantiser: ICtCp's chroma rows sum to nought, so under a response that compresses like a logarithm, dimming the blue primary is a step in intensity and nothing else. Replace the quantiser by a linear response and the blue falls to 2.15; by a logarithm, it rises to 3.39. A brighter display sharpens it further.

matching · Gamut
The lens band a fit reports for a macula that peaks off 460 nm. For an observer at sixty with no band in the lens and a macula peaking 6 and 3 nm short of the model's 460, at 460, and 3 and 6 nm long, the band the five-number fit reports from the exact matches, as its amplitude over its standard error, with one and two sessions. A macula 3 nm short is read as a band of 0.061 at 438 nm from two sessions, 3.1 standard errors; a macula peaking long has no band to become, and at 6 nm long the fit runs to the edge of the range a band may take.

A macula three nanometres short is a lens band

Two colour-matching sessions can fit a band of extra absorption in an older lens, its size and its centre, and the test proposed for real older observers was to count those with a band more than twice its standard error. That test assumes a significant band can only be a band. The observer model's macula peaks at 460 nm; a real one is two carotenoids whose mix moves its peak by a few nanometres. Simulated with its macula peaking three nanometres short and no band at all, an observer at sixty is fitted with a lens band of 0.06 at 438 nm, three standard errors, and noisy sessions find it in nineteen of twenty experiments. Six nanometres short, the phantom is larger than the band the earlier essays searched for. The confusion runs both ways: a real band fitted with the macula's peak free reads as a macula two to three nanometres short. Neither fit alone can tell them apart. Comparing the two can, with two sessions — never preferring the macula for a real band, and preferring it in sixteen to nineteen experiments of twenty for a short macula.

eye · Cones
What adaptation cannot remove from an orange ramp, screen by screen. For an orange ramp on brightened office paper, the hue turn against the solid that a reader fully adapted to the sheet still sees beyond what the sheet's colour accounts for, on conventional screens of 100, 150, 200 and 300 lines and on stochastic screens of 10, 20 and 35 µm dots, every dot with a six-micrometre rim. The 150-line screen falls from 8.1° to 5.7° along the ramp; the 20 µm stochastic screen stays near 9.0°; the 10 µm one rises, from 10.4° to 11.4°. The axis starts at 4.5°.

Stochastic dots hold the glow at every tint

On brightened paper a halftone tint keeps a hue turn that a reader fully adapted to the sheet cannot remove, because the paper's glow survives under the ink where the solid puts it out, and a dot's thin edge lets more of it back. A dot's size at a given coverage is set by the screen. Across conventional rulings from 100 to 300 lines the residue rises at every coverage for every pigment, a finer screen making every dot more edge. A stochastic screen of twenty-micrometre dots holds it flat — the orange within a quarter of a degree from five per cent to sixty, starting where a 300-line screen starts — as predicted. What the prediction did not say is where the switch costs: not the pale tints, by under a degree, but the mid-tones, by three or four, because a conventional screen's mid-tone dots are large and mostly full film. On ten-micrometre dots, all edge, the ramp turns over and the mid-tone keeps more than the pale tint. At any one coverage the residue is set by the dot's diameter alone, whichever screen printed it.

brain · Appearance
How much of the screen a warm room tints, with the black declared in grey. For each of nine cases — three pictures on a local-dimming panel, three diffuser spreads — the share of the 576 zones whose dark greys a 2,700 K room's reflected light tints by more than one ΔEITP, when the panel's black is declared as two floors in grey. At a hundredth of a candela the moon's screen is 92 per cent tinted; at a tenth, all of it, and the subtitles' too; at one candela every zone of every picture.

A warm room tints the black, not the halo

A local-dimming panel's black can be declared as two floors, the room's light reflected off the screen folded in, and the earlier censuses gave that light a hundredth of a candela, grey. Under a warm lamp it is not grey. The prediction was that a warm room would hide the halo's misreading in the long and middle cone signals, leave its short-wave part exposed, and tint the halo's dark greys towards blue. The tint is real and it is none of those things. With the floors declared in grey, a 2,700 K room putting a tenth of a candela on the screen tints every zone of a dark picture by more than one ΔEITP — up to 17.7 at the darkest grey — and the tint points towards the lamp's own orange, opposite blue. It is not the halo's: it is the whole black's, because a grey declaration has the floor's colour wrong everywhere. The prediction's conclusion holds by a different road. A grey step laid on a warm floor is partly a change of colour, so the warm room leaves seven tenths of the moon picture's grey steps misread where a grey room leaves none; and declaring the floors in the room's colour removes all of it but the halo's own.

difference · Metric
How far the merged design misses each lamp it never saw. For fourteen lamps outside the census — radiators and daylights, tinted and filtered lamps, white LEDs varied in their phosphors, and a three-band LED — the camera's colour error less the estimate the merged design makes from the ambient-light sensor's departures, fitted on the whole census. The dotted lines are the census's own held-out error, ±0.13. The radiators, daylights and tinted lamps fall inside or on it; 4 lamps fall outside, every one of them an LED.

New LEDs miss the line their cousins drew

An ambient-light sensor's three departures can estimate a camera's colour error under a lamp, and merging radiators and white LEDs into one smooth family brought that estimate to ±0.127 over fifty-four lamps, each left out in turn. Every one of those lamps had relatives in the pool. Fourteen lamps the census never saw test what the relatives were worth. The prediction was that new smooth lamps would land on the line and tinted incandescents fall off it by four tenths or more. The radiators and daylights land on it, within ±0.13 each. The tinted lamps do too — the pink-glass incandescent, placed among the LEDs by its nearest neighbour, misses by 0.12. The lamps that fall off are the new white LEDs: ±0.20, half again the census's error, two of them by a quarter. Their misses follow the sensor's 640 nm channel at a slope of −0.72, explaining four fifths of their scatter, because the line learned what that channel means from LEDs varied only in their blue pump. Adding the fourteen to the pool does not help.

imaging · Capture
The blue corner in four units, as the blue primary moves towards the violet. For displays with red and green primaries at 630 and 530 nm and a monochromatic blue primary from 440 to 490 nm, the blue corner's move per unit of margin in CIELAB, ΔE₀₀, CAM16-UCS and ΔEITP. ΔEITP's blue is sharpest at 485 nm, ×4.37, and falls to ×1.23 at 440; CIELAB's runs the other way, from ×1.92 at 480 nm to ×11.8 at 440, and ΔE₀₀ follows it; CAM16-UCS stays near a face.

A violet primary is no spike to the quantiser

ΔEITP makes a display's blue its sharpest corner, about three times a margin, and the account of why predicted that a shorter-wavelength blue would be sharper still — past four times by 450 nm. Moving a monochromatic blue primary from 490 nm to 440 does the opposite. ΔEITP's blue corner is sharpest at 485 nm, ×4.37, and falls at every step to ×1.23 at 440, where CIELAB's runs the other way, from ×1.92 at 480 to ×11.8, and ΔE₀₀ follows CIELAB. The spike needs the two primaries that can be added to the blue to move it in nearly the same direction. Adding red always raises the blue's L signal by the larger fraction. Adding green does so only while the blue carries enough M signal of its own; a violet primary carries almost none, so adding green raises its M by the larger fraction and the two steps split, from 37 degrees apart to 111. No cone response rescues it — a logarithm blunts the violet further — and a brighter display dulls it while sharpening the longer blues.

matching · Gamut
How often a six-number fit finds both departures. For nine observers at sixty, each with a lens band of a tenth of a density at 415, 430 or 445 nm and a macula moved by −3, 0 or +3 nm, the number of twenty noisy experiments in which a fit of all six numbers finds the band beyond twice its standard error, and finds the macula moved beyond twice its standard error — with two sessions and with one. With two, both are found in most experiments wherever both are present; with one, neither is.

A second session keeps a band and the macula apart

A lens band and a macula peaking a few nanometres short look alike to a colour-matching fit that has only one of them, and an older eye may have both. Fitted with all six numbers — rod weight, lens age, macular density, the band's amplitude and centre, and the macula's peak — nine simulated observers at sixty, each with a band at 415, 430 or 445 nm and a macula moved three nanometres either way or not at all, test whether the matches can carry both. The prediction was that the band at 445 and a short macula would trade almost completely, a correlation beyond 0.95 and the band's standard error tripled. That is what one session does: correlations of 0.91 to 0.95 at 430 and 445 nm, and a band found in at most twelve experiments of twenty. Two sessions do not. Their correlations stay between 0.42 and 0.83, the band is found in twelve to twenty experiments for every observer, and a moved macula in twelve to nineteen — while an unmoved one is found moved in at most three. The price of the extra number is paid by the band nearest the macula, whose standard error rises by three quarters; the rod signal pays almost nothing.

eye · Cones
What merging the spots gives back along an orange ramp. For an orange ramp on brightened office paper, the turn a reader fully adapted to the sheet still sees beyond the sheet's colour, on a stochastic screen of twenty-micrometre square spots kept separate and merged where they touch, beside the round-dot stochastic screen and a 150-line screen. Merged and separate agree until the spots begin to touch near thirty per cent; at sixty per cent the merged screen keeps 6.9° against the separate spots' 8.6°. The axis starts at 4.5°.

Merged spots give the mid-tones half the glow back

On brightened paper a halftone tint keeps a hue turn a reader adapted to the sheet cannot remove, and a stochastic screen's small dots, being mostly thin edge, keep it high along the whole ramp — three times the 150-line screen's cost in the mid-tones. That census kept every dot separate. A real stochastic screen's spots touch and merge, and a shared edge between two spots is no edge of the ink. The prediction was that a merged screen would follow the separate-dot curve to about thirty per cent and then fall towards the conventional screens, giving back half the mid-tone cost by sixty. It does, almost exactly. Square spots twenty micrometres on a side, switched on in a dispersed order, stay apart up to a fifth coverage and start touching near thirty per cent; by sixty, nine in ten touch, the rim has fallen from 84 per cent of the ink to 50, and the merged screen keeps the orange's residue at 6.9 degrees against the separate spots' 8.6 and the 150-line screen's 5.7 — giving back 58 per cent of the cost. Every pigment gets back the same share, 55 to 58 per cent, because the share is set by the geometry of the ink, not by its colour.

brain · Appearance
A stricter fit makes the reversed tube's declaration fail sooner. Through two nanometres, with every mercury line behind its own column, the ceiling built on the width the table declares — as a multiple of the reversed lamp's true peak in the worst window — at fit thresholds of half, a fifth and a tenth of a per cent, behind columns half as wide as the lines and as wide. Every stricter threshold lowers the ceiling at every depth; behind the cool column it falls below the true peak from a depth of two instead of two and a half.

A stricter fit declares a wider line

A two-nanometre table of a mercury lamp whose every line is self-reversed admits every reversed line as a Gaussian within half a per cent, and declares a width its own ceiling cannot stand on from a depth of two and a half. The obvious repair is to fit harder. The prediction was that at a tenth of a per cent the table refuses the reversed blue and green lines, admits the least-reversed yellow, declares unsafely from it between — and that a threshold that strict would refuse even unreversed lines on a real instrument's noisy table. The refusals come where predicted: the blue from a depth of three, the green from four. But the stricter threshold makes the declaration less safe, not more. It narrows the range of widths each line admits from below, so the yellow, never refused, declares a wider width at every depth, and the ceiling built on it falls below the true peak from a depth of two instead of two and a half. And a tenth of a per cent survives a quiet instrument: no unreversed line is refused until the table's noise reaches half a per cent — and then the first line refused is the yellow, the one that declares.

light · Light
The slot's paint gains at a coarse division and loses at a fine one. In the tall narrow slot — one unit wide, two and a half tall, 0.35 deep, its ceiling the lamp — with its floor painted and with its ceiling painted, the mean change over seventy-two paints in the chroma of the painted face's light when a satin finish is laid on the grey faces, solved with every face divided into one to eight strips a side. Undivided the paint gains 0.28 per cent (off the scale, clipped); at two and three strips it still gains, barely; from four strips it loses, and the loss grows at each finer division, to -0.055 and -0.059 per cent at eight.

The slot's loss survives every finer division

Read on the painted faces alone, a satin finish on a room's grey faces makes the paint more colourful in twenty-eight of the painted census's thirty rooms and less colourful in two: the tall narrow slot with its floor painted and with its ceiling painted, where the paint loses about a twentieth of a per cent of its chroma. A loss that small could belong to how finely the slot's faces were divided, and the prediction was that it does not — that the sign holds at seven and eight strips a side. It holds. Solved from one strip a side to eight, the slot's paint gains at one, two and three strips and loses from four on, every one of seventy-two paints crossing at the same division; the loss deepens at every finer division, to −0.055 and −0.059 per cent at eight strips, and run out to no strip width it settles near −0.058 and −0.065. The coarse census had the sign wrong; the census at six strips had it right. The bright, broad paints lose most, as they gained most everywhere else.

scene · Scene
The slot's loss turns to a gain about six tenths of the way deep. A box one unit wide and two and a half tall, lit by its whole ceiling, with its floor painted and with its ceiling painted, solved at eight depths from the slot's 0.35 to the tall room's full unit at four strips a side. The mean change over seventy-two paints in the painted face's chroma when a satin finish is laid on the grey faces: a loss of 0.031 per cent at 0.35, shrinking through 0.45, 0.55 and 0.6, a gain from 0.65 that grows to 0.052 per cent at a full unit. The floor turns at a depth of 0.62 and the ceiling at 0.63.

The finish stops costing the paint six tenths deep

In the tall narrow slot a satin finish on the grey faces costs a painted floor or ceiling a little of its chroma; in the tall room, the same box a full unit deep, it adds some. Solved at eight depths between, the sign turns at 0.62 of the box's width with the floor painted and at 0.63 with the ceiling — later than the prediction of 0.45 to 0.55, and far enough along that the loss belongs to a range of shallow boxes rather than to the slot alone. A finer division moves the turn a little deeper, not back. Every one of seventy-two paints turns at the same depth, and each paint's share of the change is the same at every depth, loss or gain. Brightness does not decide it: the finish brightens the painted floor by between half and more than double while hardly touching the painted ceiling, yet the two turn together. What decides it is which reflectance the finish favours — whether it multiplies the light that has been back to the paint by more or by less than the light that has never touched it.

scene · Scene
A phosphor grid's camera error is a V about the locus. Forty-eight white LEDs varied in pump, converter share and red phosphor (circles, shaded by red phosphor) and the census's forty-four (squares), placed by how far each white sits from the Planckian locus and by the camera's mean colour error under it. Across the grid the error rises away from the locus on both sides — correlated 0.68 with the distance on the green side and -0.64 on the pink — and is lowest near it. Every one of the census's LEDs sits on the green side, from 0.007 to 0.034.

LEDs varied in their phosphors fall off every line

The merged smooth family estimates a camera's colour error from an ambient-light sensor's departures to ±0.127, and five new white LEDs, varied in their phosphors where the census's forty-four vary their pump, missed by ±0.196 because the family's line had learned almost nothing about the sensor's 640 nm channel. Rebuilt on forty-eight LEDs varied in pump, converter and red phosphor, the line learns it: its 640 nm weight goes from −0.13 to −0.74, most of the way to the −0.85 the new LEDs implied. The prediction was that the new LEDs would then land within ±0.13. They miss by ±0.229, worse than before, crossing to the other side of the line, and the census's own held-out error more than doubles, to ±0.294. No pool of LEDs restores it, and no line in the sensor's departures reads the grid's own LEDs better than ±0.29. Across the grid the camera's error is a V about the Planckian locus, rising away from it on the green side and on the pink — and every one of the census's LEDs sat on the green side.

imaging · Capture
One nanometre finds the yellow's notch; two find a spike. The depth of the notch a reversed-line fit finds at the reversed tube's 578 nm yellow peak, every line behind a column half its width, on the clean one- and two-nanometre tables at eleven column depths. On the one-nanometre table the notch is -0.02 of the line when nothing is reversed and grows at every depth, to 0.99. On the two-nanometre table it is negative at every depth — from -4.2 to -0.06 — a spike added to sharpen a wide Gaussian, not a notch cut from a reversed one.

Two nanometres hide the yellow's notch from any fit

A plain Gaussian fit admits the reversed tube's 578 nm yellow line at every threshold on a two-nanometre table, and the ceiling built on its width fails from a column depth of two and a half. A fit with the notch in it — an emitted Gaussian with an absorbed one taken out of its centre — might see what the plain fit cannot. The prediction was that two nanometres leave too few entries to determine the notch, and one nanometre finds it from a depth of two. Two nanometres hide it completely: the best notch fit carries a negative notch, a spike, at every depth, and the readings a two-standard-error rule calls reversed are the same noise draws at every depth, each fitting a notch that erases the whole line. One nanometre finds it sooner than predicted — in every reading from a depth of one and half of them at a half — and its fitted depth climbs with the column. But its standard error cannot be trusted with seven entries and four numbers: the rule calls a third or more of unreversed readings reversed. The notch's fitted depth itself separates them cleanly.

light · Light
Searched harder, the band pigments lose fewer directions under every lamp. Under each of nine lamps, how many directions of the object-colour solid each pigment model reaches less than ninety-nine per cent as far as the ideal pigment: the slope limit, solved exactly, and the two band models searched from 594 starts, with the census's count from its few structured starts beside them. Over the nine lamps the band model's count falls from 395 to 335 and the energy model's from 370 to 311; the slope limit's 463 does not move.

A harder search pulls the band pigments away from the slope limit

Every count in the pigment-limit censuses — how many directions of the object-colour solid a slow pigment cannot reach within one per cent of the ideal — compares a slope limit solved exactly with two band models searched from a few structured starts. Under the mercury lamp a search from 680 starts had already found the band model reaching further in seventeen of twenty-five directions. Searched from 594 starts under all nine lamps, both band models reach further in between three fifths and nineteen twentieths of the directions they lost, and their counts fall by a sixth: 395 to 335 for bands in nanometres, 370 to 311 for bands in energy, while the slope limit stays at 463. The rankings the censuses reported hold where they were stated. What moves is everything measured against the slope limit: its lead over the band models grows from a sixth to more than a third, the coating's odd ranking — bands losing more than the slope limit — disappears, the triphosphor tube passes the three emitters for bands in nanometres, and under the mercury lamp the band models' deep losses halve.

limits · Limits
A line on the macula's peak frees the band; one on its flank does not. For the band at 445 nm, its standard error in the six-number fit over its value when the macula's peak is not fitted, with the third session's line at 465 to 510 nm. Two sessions leave it at ×1.78 and a repeated second session at ×1.41. The cyan line at 487 nm leaves it at ×1.51, worse than the repeat; at 465 nm, near the macula's 460 nm peak, it comes to ×1.16, inside the prediction's quarter.

A line on the macula's flank buys less than a repeated session

Fitted with six numbers, two sessions of colour matches keep a lens band and a moved macula apart, but the band at 445 nm pays for it: correlated with the macula's shift at 0.82, its standard error 1.8 times its value when the macula is not fitted. A moved macula changes its long flank past 470 nm, where no lens band reaches, so a third session — the LED against a lamp with a narrow line at 487 nm — was predicted to bring the correlation under 0.6 and the band's error within a quarter of its band-only value. The correlation falls to 0.80 and the error to 1.5 times. A third session that simply repeats the second does better on both errors. The flank line pins how much macular pigment there is, not where it peaks, and it ties the band's height to its centre. Moved to 465 nm, onto the macula's peak, the same session brings the band within about a fifth of its band-only error — but no position of the line brings the correlation below 0.78. The band at 445 nm and the macula's peak are told apart by their short flanks, and a third session adds matches rather than a new kind of evidence.

eye · Cones
A taller box turns deeper. Boxes one unit wide and 1.5, 2.5 and 4 tall, lit by the whole ceiling, floor painted, at depths from 0.2 to 2: the mean change over seventy-two paints in the painted floor's chroma when a satin finish is laid on the grey faces. The 1.5-tall box gains at every depth from 0.35, turning near 0.26; the 2.5-tall box turns at 0.62; the 4-tall box loses at every depth to 1.5 and turns at 1.67, deeper than it is wide.

A taller box must be deeper before the finish adds colour

In a box one unit wide and two and a half tall, a satin finish on the grey faces costs a painted floor a little of its chroma when the box is shallower than 0.62 of its width and adds some when it is deeper. Whether that turn is set by the width or by the height was the open question, and the prediction was that it scales with the height, because the satin walls pipe the lamp down to the floor and a taller box is a longer pipe. It does, and faster than in proportion. A box 1.5 tall gains at every depth from 0.35 and turns shallower than that; a box 4 tall loses at every depth to half again its width and turns near 1.67. As a share of the height the turn rises from about 0.17 to 0.25 to 0.42 — close to a depth growing as the square of the height. The taller box pipes far more of the lamp to the floor, tripling its light at 0.35 deep, and at every depth of every box the paint's colour still follows which reflectance the finish favours. Six strips a side keep both new boxes' signs.

scene · Scene
A known density frees two sessions, not the line on the peak. For an observer at sixty with a lens band at 445 nm and an unmoved macula, the correlation between the band's amplitude and the macula's shift when the macular density is fitted with the other five numbers, and when it is known exactly and fixed, under two sessions, the second session repeated, and the cyan session with its line at 465 to 510 nm. Fixing the density takes two sessions from 0.83 to 0.62 and the line at 465 nm, on the macula's peak, only from 0.86 to 0.74: the line that freed the band's error best is left with the strongest trade.

Knowing the macula's density frees two sessions, not the line on its peak

Fitted with six numbers, an older observer's colour matches cannot fully split a lens band at 445 nm from a macula whose peak has moved: their correlation stays above 0.78 under every third session tried. The proposal was to measure the macular pigment's density from outside the matches, leaving five numbers, and the prediction was that a line on the macula's peak would then split the pair below 0.6 while two plain sessions stayed near 0.8. It runs the other way. With the density known exactly, two sessions fall from 0.83 to 0.62 and the line at 465 nm only from 0.86 to 0.74. The density was the road the band and the peak traded along — correlated with each at about −0.75 in two sessions' fit — and the designs that had already narrowed that road gain least from closing it. A realistic outside measurement closes almost none of it: the matches already know the density to 0.027, so a flicker measurement good to 0.05 moves the correlation by three hundredths. And far from the macula, at 415 nm, a known density binds the band to the peak more tightly than before.

eye · Cones
Where in the plan a satin surround takes colour, at six strips. Every box 2.5 tall solved at six strips a side with its floor painted, placed by its floor's width and depth and again turned a quarter, since only the floor is painted and the turned box is the same box. The finish takes colour from the paint wherever the floor's shorter side is under about half a unit — the half-unit box at 1.25, 1.5 and, by its twin, 2 deep, the two-unit box at 0.35 and 0.5 — and from the one-unit box at 0.6; it adds colour once the shorter side passes 0.65, and at the two-unit box a quarter deep.

The width moves the turn only when it is the narrower side

In a box one unit wide and two and a half tall, a satin finish on the grey faces costs a painted floor a little chroma when the box is shallower than about 0.64 and adds some when it is deeper. The prediction was that the width hardly matters — that the two end walls a depth apart form the pipe that carries the lamp down, and wider walls only add more of it — so the turn would move by under a tenth between widths. Solved at six strips a side, a box two units wide turns between 0.5 and 0.65, within the tenth or so predicted. A box half a unit wide still loses at 1.5 deep, and its quarter-turned twin says it still loses at 2: its turn is more than a unit and a quarter deeper. With only the floor painted a box w wide and d deep is the box d wide and w deep, so depth and width are one question, and the answer is that the floor's shorter side decides: under about half a unit the finish greys the paint, past about 0.65 it colours it. The scan's first pass, at four strips, said otherwise, and got four of seven signs wrong in the long, thin boxes.

scene · Scene
A density a tenth wrong moves the band by more than its error. For an observer at sixty with a lens band at 445 nm and an unmoved macula, fitted from two sessions with the macular density fixed at 0.8, 0.9, 1.1 and 1.2 times its true 0.35: the bias in the band's amplitude and in the macula's fitted peak, in units of the fixed fit's standard errors. A tenth too high lowers the band by 1.4 standard errors and moves the peak 1.25 nm short; the prediction was a third of a standard error and under half a nanometre.

A density a tenth wrong costs the band more than fitting it

An older observer's colour matches carry a lens band and a macula that can trade against each other, and fixing the macular pigment's density from an outside measurement breaks much of that trade when the density is right. A flicker measurement and a colour match average the pigment over different fields, so the fixed density can be wrong by a tenth or more, and the prediction was that a tenth too high takes about a third of a standard error off a band at 445 nm and moves the macula's peak by under half a nanometre. It takes 1.4 standard errors off the band and moves the peak 1.25 nm short. At 415 nm the same error pushes the band the other way, up by 2.4 standard errors, and runs its fitted centre 5.6 nm shorter and the lens's age three years younger. Bias and error together, a density fixed a tenth wrong gives the band at 445 nm a larger error than leaving the density free; the break-even is about eight per cent. Given as a measurement with its own standard error of 0.03 instead of fixed, the same wrong density biases the band by under half its error.

eye · Cones
A square floor turns later than an oblong one. Boxes 2.5 tall solved at six strips a side with the floor painted and a satin finish on the grey faces: the mean change over seventy-two paints in the floor's chroma, against the floor's shorter side, for square floors and for floors whose longer side is one unit and two. The square floor loses at every side to 0.7 and gains from 0.8, turning near 0.78; the floor one unit long turns at 0.64 and the floor two long at 0.51.

A square floor needs more room than a long one

A satin finish on a room's grey faces costs its painted floor a little chroma when the room is narrow and adds some when it is wide, and in a box two and a half tall the turn was found on the floor's shorter side — 0.64 when the longer side is one unit, about 0.51 when it is two. The prediction for a square floor, with no longer side to speak of, was a later turn, near 0.7, because both pairs of walls are then equally close and both carry the lamp down. Solved at six strips a side, the square floor loses for every one of seventy-two paints at 0.5, 0.6 and 0.7 on a side and gains for every one from 0.8, turning near 0.78. A floor 0.7 by 0.7 loses where a floor 0.7 by one gains. The finish brightens the square's darkest floor by more than an oblong's at every shorter side — by a hundred per cent against forty-six at half a unit — and the turn falls steadily as the longer side grows: 0.78, 0.64, 0.51. The longer side matters, and the light-pipe account says why.

scene · Scene
Near the macula a wrong density moves every experiment together. For an observer at sixty with a lens band at 445 nm and an unmoved macula, two sessions: each of twenty simulated experiments' fitted band amplitude with the macular density held a tenth low, at its truth and a tenth high. A tenth high moves the band by -0.031 on average with a spread of 0.0024 between experiments; a tenth low by 0.030, spread 0.0022; the band's own standard error is 0.023.

A wrong density shifts every experiment alike near the macula

Read from the expected matches, a macular density fixed a tenth too high lowers an older observer's lens band at 445 nm by 1.4 of its standard errors and raises a band at 415 nm by 2.4. Real experiments carry noise, and the prediction was that their fits scatter about those biases with the fixed fit's own error, so that a tenth's mistake puts the band beyond twice its error in about a third of experiments at 445 nm and two thirds at 415. Twenty simulated experiments per case, each fitted with the density free and held at 0.9, 1 and 1.1 of its truth, give five of twenty at 445 nm and sixteen at 415 under two sessions — eight and eighteen with a line on the macula's peak. Near the macula the bias is a rigid shift: every experiment moves by the first-order amount to within a tenth of a standard error. Far from it the bias is lopsided — up by 0.058 for a density too high, down by 0.032 for one too low — and a density too low erases the band altogether in one experiment of twenty.

eye · Cones
One session, two valleys: the macula where it is, or far short. For the observer with a band at 415 nm and an unmoved macula, one session: each of twenty experiments' census fit in band amplitude and macula peak, and, for the 7 the census missed, the better fit, joined to the census's. Every better fit puts the macula seven to nineteen nanometres short: a second valley in which a macula moved far short does part of the band's work.

One session has a second valley

Every essay on older observers since the second session has read its fitted lens bands and macula shifts from one census: nine simulated observers, three designs, twenty noisy experiments each, every fit a damped descent from two starts. Two of forty experiments refitted in the last essay found a better fit than the census had. The prediction was that the census misses one fit in twenty, almost all where the band is small, and that the misses change no count it reported by more than a few hundredths. Refitted from three more starts, 66 of its 540 experiments have a better fit — 45 of 180 under one session, 9 and 12 under two and three. Sixty of the 66 better fits move the macula's peak more than two nanometres further short, most shrinking the band, and 31 lie lower by under one unit of χ²: a second valley, nearly level with the first. Two sessions' counts stand to within one or two experiments. One session's do not: with the best fits an unmoved macula is reported moved in eight experiments of twenty, where the census said one.

eye · Cones
A floor three units long never loses its colour to the finish. Boxes 2.5 tall solved at six strips a side, floor painted, satin on the grey faces: the mean change over seventy-two paints in the floor's chroma against the floor's shorter side, for a square floor and floors two, three and four units long. The square loses to 0.7 on a side and the floor two long between 0.35 and 0.5; the floors three and four long gain at every shorter side from 0.35, by 0.026% to 0.151%.

A long floor never loses its colour to the finish

A satin finish on a room's grey faces costs its painted floor a little chroma when the room is narrow, and the shorter side at which the cost turns into a gain fell as the floor grew longer — 0.78 for a square, 0.64 for a floor one unit long, 0.51 for two. The prediction was that it settles near 0.45 by four units, the limit of a slot whose far walls pipe nothing. Solved at six strips a side, floors three and four units long gain chroma for every one of seventy-two paints at every shorter side from 0.35 to 0.65: there is no turn to find. The floor two units long already loses only in a window, shorter sides from about 0.3 to just past 0.5, and gains on either side of it; by three units the window has closed, and a four-unit floor gains more than a three-unit one everywhere. The loss was never the slot's. It belonged to the far pair of walls, and moving them away removes it.

scene · Scene
Every box's verdict, in length and width. Every solved box with its floor two to four units long, placed by its shorter and longer sides and marked by its verdict: all seventy-two paints gaining chroma under the satin finish, or all losing. The losses form a wedge that narrows from 0.35 to 0.5 at two units to 0.4 alone at two and a half, and is gone by three.

The window of loss closes from both ends

A satin finish on a room's grey faces costs a painted floor a little chroma only in narrow rooms near square, and a floor two units long loses it only in a window of shorter sides, from about 0.30 to 0.51, while a floor three units long never does. The prediction for the floor two and a half units long was that the window closes from below: a gain at a shorter side of 0.3 and a loss only near 0.4 to 0.5, because the lower edge is where the far walls' pipe is weakest. The floor gains at 0.3, loses at 0.4 — by under six thousandths of a per cent — and gains again at 0.5. The window closes from both ends at once, to 0.39–0.42, and its deepest point rises through nought near 2.6 units long. Every box is still all or nothing, every one of seventy-two paints with the same verdict, and every verdict has the sign of the finish's tilt across the floor's reflectance. The far walls' cost shrinks smoothly with their distance and centres on a shorter side of about 0.4.

scene · Scene
Scaled by the height, the two rooms close their windows together. The deepest change in the painted floor's chroma over each length's solved shorter sides, against the floor's length over the room's height, for boxes 2.5 and 4 units tall. The 2.5-tall box's dip crosses nought at 2.59 units, 1.04 times its height; the 4-tall box's at 4.04, 1.01 times.

A taller room keeps its floor losing in proportion

A satin finish on a room's grey faces nearly always adds a little colour to a painted floor, and in a box 2.5 units tall it takes some away only in a pocket of proportions: floors shorter than about 2.6 units, with a shorter side near 0.4. The prediction was that the pocket scales with the room's height — that a box four units tall keeps losing until its floor is about 4.2 units long, 1.04 times its height as in the lower box. It loses until 4.04 units, 1.01 times its height: the crossing scales, a little short of the prediction. The pocket moves too. At a shorter side of 0.4, where the lower box lost, the taller box's floor gains at every length; its losses sit at 0.6 — at three and four units long — and at 0.8 when three units long, and its deepest loss lies near a sixth of its height, as the lower box's did. Every box is still all or nothing across seventy-two paints, and every box's change carries the sign of its finish's tilt across reflectance.

scene · Scene
Bounded, one session stops finding a macula that never moved. For the three bands with the macula unmoved, how many of twenty one-session experiments report it moved beyond twice its standard error: from the census's two starts, from the best of five starts, and from the best of five with the shift held within ±6 nm. The bound brings the false shifts at 415 and 430 nm from 8 and 6 to 1 and 2.

A bound on the macula trades false moves for hidden ones

Fitted thoroughly, one session of an older observer's colour matches finds a second valley in a quarter of its experiments — the macula's peak moved ten or more nanometres from the model's, where no real macula sits — and reports a moved macula where there is none in up to eight experiments of twenty. The prediction was that holding the macula's shift within six nanometres either way, the range real pigment mixtures span, restores every observer's one-session counts to within two of the census's and leaves about one fit in four pressed against the bound. The false moves vanish: an unmoved macula is reported moved in one, two and one experiments of twenty for the three bands, against eight, six and two unbounded. Seven of nine observers keep their count of moved maculas within two of the census's. But only one fit in six ends on the bound, and beside the band at 445 nm the bound hides real moves: a macula truly three nanometres short is found in three experiments of twenty, where the census found seven. Two sessions barely notice the bound.

eye · Cones
The prior trades the macula's moves for the lens band. For each observer, how many more experiments of twenty find the lens band under the prior than under the census's fits, against how many more find the macula moved. The observers moved short or unmoved gain up to seven bands and lose one to five moves — false ones where the macula never moved, real ones where it did; those moved long gain no band and lose one or two moves, the 445 nm observer losing three bands as well.

A soft prior on the macula frees the lens band

One session of an older observer's colour matches, fitted thoroughly, can drift into a valley where the macula's peak sits ten or more nanometres from any real eye's, and a hard bound at ±6 nm removes those false moves at the cost of hiding some real ones — beside a lens band at 445 nm, a macula truly three nanometres short is found in three experiments of twenty where the census found seven. The prediction was that a Gaussian prior four nanometres wide, which lets a fit go further when the matches insist, keeps the false moves away and restores those real ones. It keeps the false moves away — none, one and one for the three bands. It does not restore the real moves: it finds them as seldom as the bound or more seldom, two of twenty beside 445 nm, because it pulls every fitted shift towards nought, to a mean of 1.2 to 1.9 nanometres for moves of three. What it buys instead is the lens band. With the macula held near the standard, the band beside it is found in ten to twelve experiments of twenty, where the census found three to seven.

eye · Cones
Two rooms' floors as long as the room is tall, read as one row. The mean change in the painted floor's chroma over seventy-two paints under a satin finish, against the floor's shorter side as a share of the room's height, for the floor four units long in the box four units tall and two and a half long in the box 2.5 tall. Where the two rooms were solved at the same proportions their points coincide. Read together the floor loses from 0.148 to 0.176 of the height, the dashed lines; the deepest loss is 0.0056% at 0.16.

A room scaled whole loses its floor to the last digit

A satin finish on a room's grey faces costs a painted floor a little of its chroma only in a pocket of proportions, and a box four units tall was found losing in proportion to a box 2.5 tall — its crossing at 1.01 times its height against the lower box's 1.04, its pocket near a sixth of the height in both. The prediction was that the answer is the room's proportions alone: that the four-tall box built as the 2.5-tall box multiplied by 1.6 gives the lower box's loss to the solver's precision, and that the floor four units long loses from about 0.55 to 0.65 wide. The scaled box gives the lower box's numbers to eleven significant figures, and a pair the census had already solved agrees to twelve. The window sits higher than predicted at both edges, from 0.59 to 0.70. And the gap between the two rooms' crossings was the census's sampling: read at the pocket, the taller room crosses at 1.029 times its height against 1.036.

scene · Scene
Each widening of the prior buys moves with bands. Over the six observers whose macula truly moved three nanometres, the real moves one session finds beyond twice their error, against the lens bands found for the four observers whose band the four-nanometre prior freed — under priors four, six and eight nanometres wide, the census's own fits and the hard bound. 4 nm: 14 moves, 44 bands; 6 nm: 22 moves, 34 bands; 8 nm: 25 moves, 25 bands; census 27 and 22; bound 19 and 20.

A wider prior gives the moves back by spending the band

One session of an older observer's colour matches, fitted under a Gaussian prior four nanometres wide on the macula's peak shift, finds the lens band beside the macula in ten to twelve experiments of twenty and real three-nanometre moves of the macula as seldom as a hard bound does. The prediction was that a prior six nanometres wide keeps the false moves at two or fewer, finds the real moves within two of the bound's counts and keeps two thirds of the band's gain, and that at eight the far valley reopens at 415 nm. Three parts hold. The fourth fails: six nanometres keeps 55 per cent of the band's gain. Read across the widths the prior traces one trade — 14 real moves and 44 bands at four nanometres, 22 and 34 at six, 25 and 25 at eight, against the unconstrained fit's 27 and 22 — and the hard bound, at 19 and 20, is worse than six nanometres on both.

eye · Cones
A narrower flank keeps most of the Lorentzian's losses. The forty-nanometre band pigment with its steep side fourteen, ten, seven and five nanometres wide at half depth: how many of the clear mercury lamp's 25 splitting directions it loses by more than one per cent, as a Gaussian and as a pseudo-Voigt with a twentieth of Lorentzian, beside the counts predicted. The Gaussian loses 4, 0, 0, 0; the Voigt 18, 13, 12, 7, where four were predicted at seven nanometres and none at five.

A narrower flank moves its wing in with it

Under a clear mercury lamp, a band pigment whose steep side is a Gaussian fourteen nanometres wide loses four of the twenty-five directions that split the green line from the yellow, and with a twentieth of Lorentzian in that side it loses eighteen, because the wing three half-widths out out-absorbs the whole Gaussian there. A Lorentzian wing falls as the square of the distance over its half-width, and the prediction was that narrowing the side to seven nanometres brings the twentieth-Lorentzian pigment back to four losses and to five nanometres to none. It loses thirteen at ten nanometres, twelve at seven and seven at five, while the Gaussian loses nothing at all three. The wing still decides: the narrower band does not stay where the wider one sat but moves fourteen nanometres in towards the line it must pass, so its wing there falls fourfold rather than eightfold.

limits · Limits
Even two sessions fall into the far valley, and the prior lifts them out. For the observer with its band at 415 nm and its macula truly three nanometres short, every two-session experiment's fitted shift at the best of five starts and under a prior six nanometres wide. Three best fits lie beyond 7.5 nm short — −11.84 drawn to −1.90, −7.73 drawn to −3.05, −11.00 drawn to −0.94 — and the rest move by a tenth or two; the mean goes from −3.89 to −2.57.

A second session leaves the prior one job

Under one session of an older observer's colour matches, a prior on the macular pigment's peak shift trades the lens band against real moves of the macula, six nanometres wide at the knee of the trade. Two sessions already find the band in twelve to twenty experiments of twenty and real three-nanometre moves in twelve to eighteen, and still report an unmoved macula moved in two to three. The prediction was that the six-nanometre prior, applied to two sessions, removes those false moves and costs nothing else. It removes none of them — two, two and none remain, about the rate at which a test at twice the standard error calls a move by chance. It costs nothing at five observers of six. Beside 415 nm, with the macula moved short, it finds four fewer moves: three of the best fits there were in the far valley, eight to twelve nanometres short, and counted as moves because their sign was right. With two sessions the far valley is the prior's only remaining job.

eye · Cones
The wedge of loss comes to a point at 1.04 times the height. Every box of the 2.5-tall room near the wedge, by its floor's sides as shares of the height, marked by whether every one of the seventy-two paints gains, every one loses, or they split, with the crossing along the row at 0.16 of the height. The floors 1.08 and 1.12 times the height long gain at 0.15, 0.16 and 0.17; the floor 1.04 times as long gains at 0.15 and 0.17 and splits at 0.16, 55 paints gaining; the row crosses nought at 1.0399.

The wedge of loss comes to a point

A satin finish on a room's grey walls and ceiling adds colour to a painted floor in almost every proportion of room, and costs it a few thousandths of a per cent of its chroma in one narrow wedge of proportions: floors about as long as the room is tall and a sixth of its height wide. The wedge was known to close between floors 1.0 and 1.2 times the height long. The prediction was that a floor 1.04 times the height long still loses at a sixth of the height and one 1.08 times as long gains at every width near it, placing the tip between them a little above the coarse crossing of 1.036. The longer floor gains everywhere, as predicted. The 1.04 floor sits on the tip itself: its change in chroma is two parts in ten million, the row crosses nought at 1.0399, and there — and in no other box of the census — the seventy-two paints part company, fifty-five gaining and seventeen losing.

scene · Scene
Every paint has its own tip, and the pale ones cross last. Each of the seventy-two paints' own crossing from loss to gain along a sixth of the height, against how far its change swings between 1.0 and 1.08 times the height relative to the mean's, by band width. The crossings run from 1.0387 to 1.0413 of the height; the swings from ×0.37 to ×3.12, and the paints that swing most cross last.

The pale paints cross the tip last

A satin finish on a room's grey faces costs a painted floor its chroma only in a narrow wedge of proportions, and at the wedge's tip — a floor 1.04 times the room's height long and a sixth of it wide — the mean change is nought and, alone in the census, the seventy-two paints part company: seventeen lose, fifty-five gain. The prediction was that the losers are the paints with the narrowest reflectance bands, whose chroma depends most on how much grey light mixes in, and that they lose most below the tip and gain least above it. The opposite holds. No narrow band loses; half the broadest do, and fourteen of the seventeen have the highest peak — the pale paints. They lose most below the tip and gain most above it: they are the paints the finish moves most, up to three times the mean, and each paint has its own tip, from 1.0387 to 1.0413 times the height, the palest last.

scene · Scene
A five-nanometre flank loses nothing up to a fiftieth of Lorentzian. The forty-nanometre band pigment's lost splitting directions against the Lorentzian share of its steep side, for a steep side five nanometres wide — the first search and the better of it and a second — and fourteen. At five nanometres: 0, 0, 0, 5 lost at no Lorentzian, a hundredth, a fiftieth and a twentieth, where the first search had 0, 0, 1, 7; at fourteen, 4, 11, 14, 18.

A five-nanometre flank carries a fiftieth of Lorentzian

A band pigment splitting mercury's green and yellow lines with a steep side five nanometres wide loses none of the twenty-five splitting directions as a Gaussian and seven with a twentieth of Lorentzian in its flank, because the band slides in towards the passed line and carries its wing there. The prediction was that at five nanometres the count follows the single band's error, which grows in proportion to the share: about two lost at a fiftieth and none at a hundredth. A hundredth loses none, as predicted. The first search lost one direction at a fiftieth — and searched again from the best pigments found at the neighbouring shares, that direction reaches within two thousandths of the ideal: a fiftieth loses none either. The same second search recovers two of the twentieth's seven, leaving five. A sharp enough flank tolerates a fiftieth of Lorentzian where a fourteen-nanometre one lost fourteen directions to it.

limits · Limits
The loss deepens to 0.16 and jumps to a gain a hundredth wider. The same row between 0.15 and 0.175 of the height. The loss deepens at every step from −0.0016% at 0.150 to −0.0056% at 0.160, turns to +0.0010% at 0.164, sits at +0.00004% at 0.168 and loses again, −0.00076%, at 0.175.

The pocket has a step where its bottom should be

Along a floor as long as the room is tall, a satin finish on the grey faces costs the floor a few thousandths of a per cent of its chroma in a pocket around a sixth of the height wide, deepest at 0.16 of the height by three samples a hundredth of the height apart. The prediction was that boxes between those samples trace one smooth dip with its bottom between 0.39 and 0.41 units, every box from 0.375 to 0.425 losing. The loss does deepen smoothly, at every step from 0.375 to 0.40. Then, a hundredth of a unit wider, at 0.41, every one of the seventy-two paints gains; at 0.42 they split; at 0.4375 every paint loses again. The row changes sign three times in a tenth of a unit of width, and the one step from 0.40 to 0.41 rises three times as fast as the pocket falls. The finish's brightening, which the chroma change rides on, falls smoothly straight through. What the census has called the pocket's bottom is a step.

scene · Scene
A third session finds the band beside the lens's edge. For each observer, how many of twenty experiments find the lens band beyond twice its error and within 20 nm of where it was put: two sessions under the six-nanometre prior, and three sessions at their best of five starts. Beside 415 nm with the macula unmoved, two sessions find it in 12 and three in 18; beside 430 nm with the macula short, 20 and 16.

A third session finds the edge band and counts bands misplaced

Two sessions of colour matches find an older observer's lens band in eighteen to twenty experiments of twenty at every place but one: a band at 415 nm, beside the lens's own short-wave edge, found in twelve. The prediction was that a third session — a phosphor LED set against a lamp with a cyan line — finds it in at least seventeen, and that the experiments losing it under two sessions fit the lens three or more years old. Three sessions find it in eighteen, and every loss under two did fit the lens older, but by under three years in five of eight. The count hid something else. It credits a band wherever a fit puts it, and up to twelve of 180 fits put it sixty to eighty nanometres from its place, on the macula's long flank. With three sessions the six-nanometre prior no longer closes that valley.

eye · Cones
The count falls by one and then by seven. The forty-nanometre pigment's lost splitting directions at a twentieth of Lorentzian against the half-width of its steep side, at the best of every search, and the count each half-width would lose if every direction fell short by its seven-nanometre constant times one band's error. Searched again, 14 nm loses 18, 10 nm loses 13, 7 nm loses 12, 5 nm loses 5; the constants predict 16 at 14, 13 at 10, 12 at 7, 9 at 6, 5 at 5, 3 at 4.5, 0 at 4.

Each direction falls short by one band's ratio

A band pigment asked to reflect mercury's green line and absorb its yellow, with a twentieth of Lorentzian in its steep side, loses eighteen of twenty-five splitting directions at a steep side fourteen nanometres wide, thirteen at ten, twelve at seven and five at five. A second search had lowered the five-nanometre count, and the prediction was that searching the seven- and ten-nanometre pigments again lowers each by one or two, leaving a count nearly linear in the half-width. Searched again, both lose exactly what they lost — no direction gains six tenths of a point. The uneven fall is real, and the reason is plainer than any search: every direction's shortfall falls with the half-width by the same factor as a single band's error, so the count is a fixed ranking of constants, one a direction, read against a line that moves.

limits · Limits
The ranking reads six nanometres to the direction. The forty-nanometre pigment's lost splitting directions at a twentieth of Lorentzian against the steep side's half-width, at every half-width searched, beside the count the ranking of seven-nanometre constants predicts. At 6 nm the ranking predicted 9 and the search found 9; at 4.5 nm the ranking predicted 3 and the search found 1; at 4 nm the ranking predicted 0 and the search found 0.

The ranking reads six nanometres to the direction

Every direction a band pigment loses under mercury's lines falls short, as its steep side narrows, by the same factor as a single band's error — so each direction carries a constant, and the count at any half-width can be read off one band with no search at all. Read that way, a twentieth of Lorentzian loses nine directions at a six-nanometre steep side, three at four and a half and none at four. Searched, six nanometres loses nine: the same nine, every direction within 6.2 per cent of where the constants put it. Four loses none. Four and a half loses one, not three — the two the ranking added sit 0.005 and 0.011 of a point under the one-per-cent line. And at the narrowest widths the gentle directions begin to fall short by more than the ranking says, by up to 29 per cent, which is where the single band stops being the whole story.

limits · Limits
Held near the lens, the band is found where it was put. For each observer, how many of twenty three-session experiments find the lens band beyond twice its error and within 20 nm of its place, with its centre free to range from 390 to 500 nm and held to 400–460. Beside 415 nm the bounded fits find it in 19, 20, 19 with the macula short, unmoved and long, against 16, 18, 15 free.

A band held near the lens closes the valley the prior could not

Three sessions of colour matches find an older observer's lens band beside the lens's own edge as predicted, but twelve of 180 fits place the band sixty to eighty nanometres away on the macula's long flank, each with the macula fitted far short — a valley the six-nanometre prior on the macula's shift no longer closes. The prediction was that holding the band's centre to 400–460 nm, where a lens band can be, empties that valley, finds the 415 nm band with the macula short in at least eighteen experiments, and raises the moves found beside 430 nm from nine to twelve. The first two hold: no fit is left in the valley, and the band is found in nineteen. The third does not: 430 nm stays at ten. And the valley turns out to have been nearly level with the truth — holding the band costs ten of the twelve fits under four units of the fit's chi-squared, and every one's macula comes home.

eye · Cones

Named alongside it

The objects these essays reach for when they reach for this one.

SpecularInterreflectionConvergenceRadiosityChromaLeast-squaresSpectral power distributionIdentifiabilityLens yellowingMacular pigmentStructural choiceAudit

All concepts