Aperture — where it appears
Named by 10 essays across 6 fields — each of them below, with the objects they name alongside it.
Either factor being zero
Four different departures from the colour integral turn out to have one algebraic form — each is an inner product of something the sample does that the model has no slot for with something the light does that the model assumed away. Either factor being zero makes the departure exactly zero, and the sizes of the two factors decide neither how large it is nor which way it goes.
An aperture is a filter
A measuring aperture throws away the light that came back outside it, and the light that comes back furthest is the light at the wavelengths the sample absorbs least. So an aperture does not attenuate a translucent sample evenly — it attenuates its peaks more than its troughs, which is a filter whose transmission curve the sample itself decides.
The hue the hole decides
A piece of pale marble measured through a wide aperture is faintly yellow. Measured through a narrow one it is faintly blue, and between the two there is an aperture at which it is exactly neutral. Nothing about the stone changes; the aperture is a filter with a colour, and what decides that colour is the size of the particles rather than the pigment between them.
Either disc can be the wide one
Every standard on translucent samples says to illuminate a larger area than is measured, and explains it by saying that light leaks out of the lit spot. That is true and it is not the reason, because the instruction works equally well the other way round — measuring a larger area than is lit gives a reading just as exact. The error is a product of two apertures and either one being wide kills it.
Which index to buy an instrument for
Four departures from the colour integral, ranked by what they cost and by what it would take to remove each one. The ranking by cost and the ranking by price are almost exactly reversed — the two largest are removed by specifying a lamp and by widening a table, and the two that need new hardware are the two smallest.
A pixel has an aperture too
A camera photographing a translucent object has the same two discs a spectrophotometer has — one lit, one looked at — and gets them the other way round. Its illumination covers the whole scene, so the flat colour of a translucent surface comes out exactly right at any magnification, and the error moves entirely into the edges.
Two departures that partly cancel
A glossy translucent sample has two of this round's four departures at once, and the expectation was that they would compound. They do the opposite. An aperture takes light away that went into the material and came back too far out; an interface returns light that never went in at all — so measuring either alone overstates what both together do, on every material tested.
A pair the aperture separates
Two constructed slabs with the same reflectance at every wavelength, to fifteen figures — the same colour to any observer under any light — and 6.25 ΔE₀₀ apart when measured through a four-millimetre aperture. It is a metamerism with no observer in it, no illuminant in it, and no spectral difference to construct it from.
The chart was measured, not photographed
A camera profile is fitted so that the camera's response maps onto the chart's tristimulus values, and those values came out of a spectrophotometer. So the profile's target carries the instrument's departures and the camera does not — a mildly translucent chart read through a four-millimetre aperture supplies targets 2.55 ΔE₀₀ from the truth, which is twice the profile's own fitting error.
The departures are larger than the tolerance
A delivery tolerance is written around one ΔE₀₀ and every one of this round's four departures is above it on ordinary material. A specification that names an illuminant, an observer and a tolerance, and does not name a measurement condition, an aperture and a field, has written a number that two honest laboratories can miss each other on by more than the number itself.
Named alongside it
The objects these essays reach for when they reach for this one.
Subsurface scatteringMarginalisationMeasurement conditionTranslucencySpecificationBilinearityDiffusion lengthEdge lossInter-instrument agreementMeasurement errorSpectrophotometryTolerance