Measurement condition — where it appears
Named by 26 essays across 8 fields — each of them below, with the objects they name alongside it.
An instrument brings its own light
ISO 13655 names four measurement conditions and they are usually read as four degrees of care. They are not. They are four different quantities — on an unbrightened sheet all four agree to a rounding, and on a brightened one they are up to seven and a half units apart, with every instrument in calibration and every answer correct.
Whiteness is mostly the lamp
The CIE whiteness formula ranks white samples the way people do, which is what it was built for and is not in question. What is in question is what it is a measurement of — take the ultraviolet out of the instrument and 82 per cent of the scale collapses, because the part that separates a premium sheet from an ordinary one was contributed by the lamp.
A tolerance cannot cross a condition
If two measurement conditions disagree by seven units, the obvious repair is a correction matrix fitted between them. The best least-squares 3×3 over seventeen printed patches leaves 23 per cent of the disagreement and makes five patches worse than doing nothing — because the term it is trying to remove is proportional to how much paper is showing, and no linear map on three numbers can express that.
A camera cannot record the excitation
Two lamps of nearly the same chromaticity, one with ultraviolet and one with none, put a brightened sheet twelve units apart after a perfect white balance. Nothing in the camera measured the difference — the filter stack removed the band before the sensor saw it — so the correction that would fix the picture needs a quantity the file does not contain.
The lamp that stopped emitting ultraviolet
A blue-pumped white LED has a die at 450 nanometres and emits nothing shorter. Between about 2005 and 2020 that lamp replaced almost every other indoor source, which removed the excitation supply from a great many rooms — so brightened materials stopped glowing indoors without a single one of them being reformulated.
A white that is not a reflectance
The object-colour solid is the hardest boundary in colorimetry — the set of tristimulus values any reflecting surface can produce, with no assumption about pigments in it at all. A coated press stock under a measurement standard's own lamp sits 1.5 per cent outside it, and a heavily brightened one 4.0, and with the ultraviolet removed both come back inside.
The brightener is being used up
The molecule that absorbs an ultraviolet photon occasionally does something other than re-emit it, and what it does is break. So a sheet's whiteness has a half-life, the fall is steepest at the start, and a specification quoting a whiteness figure without a date is quoting a property of a sheet that no longer exists.
A brighter white still looks white
Colorimetry says a brightened sheet is nine units of b* from neutral, which sounds like a visible blue. An appearance model with the observer adapted to the room says it carries eleven units of chroma at a hue of 295 degrees — genuinely blue-violet — and that the number falls by nearly half between a bright room and a dark one. What it cannot say is why anybody calls the result white.
An aperture is a filter
A measuring aperture throws away the light that came back outside it, and the light that comes back furthest is the light at the wavelengths the sample absorbs least. So an aperture does not attenuate a translucent sample evenly — it attenuates its peaks more than its troughs, which is a filter whose transmission curve the sample itself decides.
Either disc can be the wide one
Every standard on translucent samples says to illuminate a larger area than is measured, and explains it by saying that light leaks out of the lit spot. That is true and it is not the reason, because the instruction works equally well the other way round — measuring a larger area than is lit gives a reading just as exact. The error is a product of two apertures and either one being wide kills it.
Which index to buy an instrument for
Four departures from the colour integral, ranked by what they cost and by what it would take to remove each one. The ranking by cost and the ranking by price are almost exactly reversed — the two largest are removed by specifying a lamp and by widening a table, and the two that need new hardware are the two smallest.
The ultraviolet is half the product
A fluorescent sample's departure from the reflectance model is exactly proportional to the ultraviolet the lamp carries — to twelve figures, over a range that includes zero. It is the only one of the round's four departures that really is a product of two magnitudes, and the reason is a rule about how molecules relax rather than anything about arithmetic.
A pair the aperture separates
Two constructed slabs with the same reflectance at every wavelength, to fifteen figures — the same colour to any observer under any light — and 6.25 ΔE₀₀ apart when measured through a four-millimetre aperture. It is a metamerism with no observer in it, no illuminant in it, and no spectral difference to construct it from.
The departures are larger than the tolerance
A delivery tolerance is written around one ΔE₀₀ and every one of this round's four departures is above it on ordinary material. A specification that names an illuminant, an observer and a tolerance, and does not name a measurement condition, an aperture and a field, has written a number that two honest laboratories can miss each other on by more than the number itself.
The slit is what makes it legal
Point-sampling a mercury line at five nanometres costs a colour difference of one unit, and a laser projector thirty-seven. Integrating the same spectrum through the five-nanometre slit every spectrometer already has costs 0.014 and 0.19. The blur anybody would remove if they could is what makes a coarse table honest.
The rods are a fourth curve
Colorimetry has three numbers and a rod signal is a fourth. It cannot be absorbed by a gain, it cannot be removed by a white point, and adding a tenth of one to a three-curve observer costs 1.60 ΔE₀₀ — the narrowest distribution of the six departures, because an addition behaves quite differently from a filter.
The instrument is one observer exactly
A spectrophotometer has no observer uncertainty. It computes through the 1931 tables to the last bit, reproducibly, forever — which is its whole value and is also why it cannot report the three colour differences of observer spread between itself and whoever is looking at the sample.
The booth and the eye disagree
A viewing booth is specified to simulate daylight, and daylight is the light under which observers disagree least. So a booth is the condition in which a specification is least likely to be tested against the thing that breaks it, and the shop it will be judged in roughly doubles the term.
Two slits are not one slit
A spectrometer's slit is what makes a coarse table honest, for a lamp and for a notched sample alike. But a colour is a sum over the product of the two, and a notch measured through one slit and a lamp measured through another are not the product measured through a slit. Under a smooth light the difference is nothing. Under a fluorescent tube a notch on the mercury line comes out 0.73 colour differences off from two slits — worse than no slit at all for some notches — and 0.02 off from one slit on the reflected light.
The metamerism index has two corrections
The index for a metameric pair is defined for a pair that matches exactly under the reference light, and no real pair does. The standard's remedy is to correct the sample first, and it names two corrections — scale the tristimulus values, or add the difference. On six pairs matched to one colour difference, the two answers differ by a tenth to four tenths of an index unit; at two, by a whole one.
A linear repair for a bilinear loss
The Stearns correction sharpens a table blurred by a triangular slit, and the obvious question was whether applying it to a lamp's table and a sample's restores the product the two of them are wrong about. It restores four fifths of the damage and cannot touch the rest: a three-term filter is linear, the covariance two separately blurred tables discard is bilinear in the two factors, and no linear operator applied to each factor separately produces a bilinear term. What is left is ten times the one-slit answer, at every position of the notch.
One slit, two requirements
A line lamp wants a wide slit, because a wide slit spreads a line where a coarse grid can see it. A notched sample wants a narrow one, because a wide slit fills the notch the grid could have resolved. An instrument has one slit. Measured on the two requirements separately the best widths are five nanometres and one; measured on the two together the best is three, which is neither — and it costs twelve times what the lamp alone would cost and thirty-four times what the sample alone would.
The ambiguity is largest where the index is used
The metamerism index is defined for a pair that matches exactly under the reference light, no real pair does, and the two corrections the standard allows for the residual give different answers. Over eighteen pairs at eleven match qualities the gap is nearly a function of the mismatch alone — its middle half spans a factor of 1.4 at the mismatches a dyehouse reaches — so it could be tabulated. And it is largest exactly there: zero at a laboratory's match, and re-grading eight pairs in eighteen at a trade's.
A second slit buys a quarter
A line lamp wants a five-nanometre slit and a notched sample a one-nanometre slit, so an instrument with a slit for each should do much better than one with a single compromise. Over sixty-eight notches under a fluorescent tube, it does better by 28 per cent. One slit on the reflected light does fifteen times better than the best pair, and an oracle choosing the best pair for every notch is still six times worse. The error was never that the factors were flattened; it was that they were flattened separately.
A rod signal has no natural size
An older lens absorbs where the S cones are sensitive, so it should make the uncertain rod-to-S-cone weight cheaper. Measured, the rod signal's catch of a phosphor LED as a share of the S cones' own catch more than doubles from twenty to seventy-five — and the share the model actually uses falls by a fifth. The two differ by the S cone's peak absorptance, which the lens takes 60 per cent of, and which entered the model as a normalisation rather than as a claim.
The shadows a unit counts are the ones a room removes
ΔEITP's growth with display brightness is largest in the dark greys, and dark greys are where a lit room's light reflected off the screen sits. One candela a square metre of veiling luminance removes 22 per cent of the difference the unit gives a step at the bottom of the scale on a 1,000-candela display and nothing measurable at the top. The same veil raises the growth the unit reports across display levels from a factor of six to a factor of seventeen, because it destroys a dim display's shadows first.
Named alongside it
The objects these essays reach for when they reach for this one.
SpecificationQuality controlSpectrophotometryFluorescenceOptical brightenersUltravioletToleranceApertureInstrumentSpectral structureWavelength gridBandpass