Fluorescence — where it appears
Named by 19 essays across 8 fields — each of them below, with the objects they name alongside it.
A lamp is not a blackbody
A fluorescent tube puts a third of its light into four mercury lines. A white LED is a blue spike with a hole beside it. Both are sold by a colour temperature, and a colour temperature says nothing about either.
Some paper is brighter than white
The reflectance model assumes light leaving at a wavelength arrived at that wavelength. A fluorescent sample breaks the assumption, has no reflectance curve at all, and is in almost every sheet of white paper sold.
A surface that is not a multiplication
Every argument here about what light does to a surface begins by multiplying two spectra together. A surface with a brightener in it takes light at one wavelength and returns it at another, so it is a full operator rather than a diagonal one — and it does not have a reflectance at all.
The tables do not stop together
This collection integrates from 380 to 780 nanometres, and decided once, in writing, that the range could not honestly be widened. The argument was correct at the long end and wrong at the short one — the CIE publishes the daylight basis from 300 nanometres, and publishes it from there for exactly the reason it matters.
A reflectance is a diagonal
A reflecting surface returns light at the wavelength it arrived at, so its whole description is one number per wavelength. A fluorescent one returns it somewhere else, so its description is a square matrix — and the curve every instrument reports is that matrix's diagonal with the rest of it folded in at whatever weight the lamp happened to give.
The eye weights where the light is not
A brightened sheet returns a quarter more light than arrives at 430 nanometres, and it is three tenths of one per cent brighter for it. The luminous efficiency function is 0.017 there against 1.0 in the middle of the band, so the whole effect lands in the blue-yellow axis — brighter than white is a colour claim wearing a brightness word.
Two sheets that match until the window
Ordinary metamerism is two reflectances that agree under one light and not another, and it can always be undone by putting the first light back. A dyed sheet and a brightened one have the same reflectance everywhere an eye can see, agree exactly under any lamp with no ultraviolet, and separate by ten units under daylight — and no change of light puts them back together.
The window is part of the light
A viewing condition here has always been a spectrum and a geometry. For anything fluorescent it needs a third thing — the transmittance of whatever the daylight came through — because ordinary window glass, a laminated windscreen and a museum filter remove three quite different parts of the band a brightener eats, and the sheet is a different colour behind each.
An instrument brings its own light
ISO 13655 names four measurement conditions and they are usually read as four degrees of care. They are not. They are four different quantities — on an unbrightened sheet all four agree to a rounding, and on a brightened one they are up to seven and a half units apart, with every instrument in calibration and every answer correct.
Whiteness is mostly the lamp
The CIE whiteness formula ranks white samples the way people do, which is what it was built for and is not in question. What is in question is what it is a measurement of — take the ultraviolet out of the instrument and 82 per cent of the scale collapses, because the part that separates a premium sheet from an ordinary one was contributed by the lamp.
A tolerance cannot cross a condition
If two measurement conditions disagree by seven units, the obvious repair is a correction matrix fitted between them. The best least-squares 3×3 over seventeen printed patches leaves 23 per cent of the disagreement and makes five patches worse than doing nothing — because the term it is trying to remove is proportional to how much paper is showing, and no linear map on three numbers can express that.
A camera cannot record the excitation
Two lamps of nearly the same chromaticity, one with ultraviolet and one with none, put a brightened sheet twelve units apart after a perfect white balance. Nothing in the camera measured the difference — the filter stack removed the band before the sensor saw it — so the correction that would fix the picture needs a quantity the file does not contain.
The lamp that stopped emitting ultraviolet
A blue-pumped white LED has a die at 450 nanometres and emits nothing shorter. Between about 2005 and 2020 that lamp replaced almost every other indoor source, which removed the excitation supply from a great many rooms — so brightened materials stopped glowing indoors without a single one of them being reformulated.
A white that is not a reflectance
The object-colour solid is the hardest boundary in colorimetry — the set of tristimulus values any reflecting surface can produce, with no assumption about pigments in it at all. A coated press stock under a measurement standard's own lamp sits 1.5 per cent outside it, and a heavily brightened one 4.0, and with the ultraviolet removed both come back inside.
The brightener is being used up
The molecule that absorbs an ultraviolet photon occasionally does something other than re-emit it, and what it does is break. So a sheet's whiteness has a half-life, the fall is steepest at the start, and a specification quoting a whiteness figure without a date is quoting a property of a sheet that no longer exists.
A brighter white still looks white
Colorimetry says a brightened sheet is nine units of b* from neutral, which sounds like a visible blue. An appearance model with the observer adapted to the room says it carries eleven units of chroma at a hue of 295 degrees — genuinely blue-violet — and that the number falls by nearly half between a bright room and a dark one. What it cannot say is why anybody calls the result white.
Which changes of light pay for it
A fitted adaptation basis beats the receptors by 0.68 units on average, and an average is a poor description of what it does. On six of fourteen changes of light it is worse, and the whole of its advantage comes from four — a tungsten lamp and three coloured walls.
The ultraviolet is half the product
A fluorescent sample's departure from the reflectance model is exactly proportional to the ultraviolet the lamp carries — to twelve figures, over a range that includes zero. It is the only one of the round's four departures that really is a product of two magnitudes, and the reason is a rule about how molecules relax rather than anything about arithmetic.
The grid is a range, not an index
Three of the four departures in this round restore an argument the model dropped. The fourth does not — the 380-to-780-nanometre grid is the range of the one argument the model kept, chosen in the first weeks and never revisited. It costs 6.70 ΔE₀₀ on a coated printing paper, it is the cheapest of the four to fix, and it is the one still unfixed.
Named alongside it
The objects these essays reach for when they reach for this one.
Optical brightenersUltravioletIlluminantMeasurement conditionRadiance factorAssertionReflectanceThe Donaldson matrixSpecificationWhitenessBispectralQuality control