Bilinearity — where it appears
Named by 7 essays across 4 fields — each of them below, with the objects they name alongside it.
Either factor being zero
Four different departures from the colour integral turn out to have one algebraic form — each is an inner product of something the sample does that the model has no slot for with something the light does that the model assumed away. Either factor being zero makes the departure exactly zero, and the sizes of the two factors decide neither how large it is nor which way it goes.
Either disc can be the wide one
Every standard on translucent samples says to illuminate a larger area than is measured, and explains it by saying that light leaks out of the lit spot. That is true and it is not the reason, because the instruction works equally well the other way round — measuring a larger area than is lit gives a reading just as exact. The error is a product of two apertures and either one being wide kills it.
The ultraviolet is half the product
A fluorescent sample's departure from the reflectance model is exactly proportional to the ultraviolet the lamp carries — to twelve figures, over a range that includes zero. It is the only one of the round's four departures that really is a product of two magnitudes, and the reason is a rule about how molecules relax rather than anything about arithmetic.
Two departures that partly cancel
A glossy translucent sample has two of this round's four departures at once, and the expectation was that they would compound. They do the opposite. An aperture takes light away that went into the material and came back too far out; an interface returns light that never went in at all — so measuring either alone overstates what both together do, on every material tested.
The audit that changed the object
Three rounds audited this collection's numbers, its sets and its conventions, and each one ended by naming the same thing it could not reach — that a surface is a reflectance. This round reached it, found that four departures share one algebraic form, had two of its predictions refused, and discovered that its own hemisphere quadrature had been passing a convergence check by luck.
A second slit buys a quarter
A line lamp wants a five-nanometre slit and a notched sample a one-nanometre slit, so an instrument with a slit for each should do much better than one with a single compromise. Over sixty-eight notches under a fluorescent tube, it does better by 28 per cent. One slit on the reflected light does fifteen times better than the best pair, and an oracle choosing the best pair for every notch is still six times worse. The error was never that the factors were flattened; it was that they were flattened separately.
The tables cannot bound what they discarded
A colour computed from a lamp's blurred table and a sample's blurred table is wrong by the covariance the two blurs threw away, and Cauchy–Schwarz bounds a covariance by two variances. With the true variances the bound always holds and sits fifteen times above the error. With variances read from the tables it fails on six of sixty-eight notches under a fluorescent tube and twenty-two under a laser projector — on the line, where the error is largest. A blurred table does not carry the width of a line, and the covariance depends on it.