The collection

Every essay — page 4

Page 4 of 40, continuing through the fields in the same order.

What light is What the eye does Matching and measuring Difference and uniformity What the brain does What a scene does What a camera does Where the model breaks What it takes to deliver it

SeriesObserversNamed objectsRefutationsSearch

What the brain does

Constancy, adaptation and simultaneous contrast — the reasons a patch of known radiance still has no determined appearance.

Where averaging the model's answers is and is not averaging its argument. Each row takes a spread of situations, averages the model's predictions across them, and compares that against the model's prediction for the average situation. The bar is the gap as a share of the spread itself. Over the differences between observers it is 1.4 per cent — the model is very nearly linear there. Over the range of adapting luminance one room covers in a day it is 59 per cent, and from indoors to outdoors 74.

Where the model's curve does not matter

This round has been about what a nonlinearity does to an average, and CIECAM16 is the most nonlinear thing in the collection. Over the spread a population of observers produces, the average of its predictions is its prediction for the average to within 1.4 per cent — the nonlinearity is there and the excursion is too small to reach it. Over the range of adapting luminance one room covers in a day, the same gap is 59 per cent of the spread, and from indoors to outdoors 74.

8 figures
The audit's six departures, read twice. Each departure priced in the matching unit it was published in and in the appearance unit an appearance prediction would be judged by. The model does not scale them by one factor: it amplifies the smallest by 1.58 and the largest by 1.03, so the range between them narrows from 3.34 to 2.17. The mean ranking is unchanged and 14 of the 42 surfaces reorder.

The audit, read as appearances

The previous round priced six observer departures in a matching unit and left them there. Read in the appearance unit an appearance prediction would actually be judged by, they are not the same six numbers scaled by a constant — the model amplifies the smallest by 1.58 and the largest by 1.03, so the range between the largest and smallest term narrows from 3.34 to 2.17. The published ranking survives in the mean and changes on fourteen of the forty-two surfaces it was averaged over.

7 figures
What a stated lightness pins down, and where. A lightness quoted to 0.05 of a unit, inverted, and the luminance it fixes. Read as a fraction of the colour's own luminance the requirement is 0.90 per cent at J 10 and 0.097 at J 95, a factor of 9.3. Read in absolute luminance it is the other way round, by a factor of 6.5. Both readings are true and they answer different questions.

A stated lightness is two requirements

A specification quotes an appearance to a stated precision — a lightness to a tenth of a unit, say — and the same precision everywhere. Inverted, a twentieth of a unit of lightness fixes the luminance to nine tenths of one per cent at the bottom of the scale and to a tenth of one per cent at the top, a factor of 9.3. Read in absolute luminance it is the other way round by a factor of 6.5, and both readings are true.

6 figures
Which appearances a surface can have, lightness by lightness. The same lattice of lightness, chroma and hue a specification is written in, 10488 points, inverted under daylight with the observer adapted to it. Each row is one lightness, split into three shares: appearances a reflecting surface can have, appearances that are a light but that no surface can return, and appearances with no light under them at all. Over the whole lattice the first is 66 per cent, the second 23 and the third 11. At J 90 a surface can have 38 per cent of the row.

A third of the appearance box is no surface

An appearance specification is written as a lightness, a chroma and a hue, and the model's inverse turns any such triple into three numbers. A tenth of the space turns into something that is not a light at all. A further quarter turns into a light no reflecting surface can return, because a surface cannot give back more than all the light at any wavelength. So a third of the space a paint, a print or a dye is specified in cannot be made from paint, print or dye, and at lightness 90 nearly two thirds cannot.

7 figures
How far the answer for the average is from the average answer, over eight spreads. For each spread of inputs, the distance between the mean of the model's answers and its answer for the mean input, as a share of the spread of the answers. Over a population of observers it is 1.4 per cent. Over surfaces it is 21 on smooth natural reflectances, 27 on a banded family with lightness in it, and 9 on a set of pale surfaces. Over the light one room sees in a day it is 59.

The average surface does not look average

Over a population of observers the appearance model is so nearly linear that the mean of its answers is its answer for the mean, to 1.4 per cent of the spread. Over the surfaces in a scene it is not. On 240 smooth reflectances the gap is 21 per cent of the spread, and the mean surface looks 4.2 units lighter than the surfaces look on average. The grey that matches the average light is a 47 per cent reflectance; the grey that matches the average look is a 43 per cent one.

6 figures
How much of a display's gamut each observer names differently. Each of 60 observers names every colour of the displayable gamut that the panel can make — 823 of them — and the histogram is how much of that gamut each observer names differently from the standard observer. On an OLED panel the median observer renames 8.1 per cent and the furthest 13.1 per cent. Nobody agrees with the standard observer about all of it.

A name moves with the reader

Three earlier essays have moved a colour's name by changing the distance function, the room and the space. All three held the observer fixed. Handed the same light from the same display, sixty observers rename between 3.5 and 13.1 per cent of the gamut against the standard observer, a quarter of its colours have a dissenter in twenty, and the narrower the display's primaries the worse it gets.

6 figures
How far CIECAM16 moves a monochromatic hue when the light is brightened thirtyfold. A monochromatic stimulus at a relative luminance of 2 and of 60, read through CIECAM16 in one room, and the difference between its two hue angles. The model was never fitted to this effect and has it anyway: the shift is positive at the short end, negative through the greens, positive again in the yellows and reds, and crosses zero at 459, 495, 502, 570 nanometres. The marks are the invariant wavelengths the literature reports — 474, 506, 571.

The model has a hue shift it was never given

A monochromatic light changes hue as it is brightened, except at three wavelengths that do not move — an effect measured since the nineteenth century and not among the things CIECAM16 was fitted to. The model has it anyway: brightening a stimulus thirtyfold moves its hue angle, and the places where the movement crosses zero land at 459, 495, 502 and 570 nanometres against the reported 474, 506 and 571. The sizes are another matter.

6 figures
What the choice of adopted white is worth, in a room lit by two lights. A room lit half by daylight and half by an incandescent lamp. The light on the surfaces is fixed; what varies is the white the model is told the observer has adapted to, running from the lamp on the left to the window on the right. The median of twelve surfaces moves 32.6 CAM16-UCS units if the lamp is adopted and 24.5 if the window is, against the room's own mixture in the middle. The model offers no way to choose, and its degree of adaptation is 0.94 at every point of the dial.

A room with two lights has no white

An appearance model takes one adapting white. A desk beside a window has two, and the mixture falling on the paper is not the same thing as the white the person reading it has adapted to. Mixing the lights is arithmetic. Choosing the white is not, and the choice is worth sixty units of appearance — most of which is a cast, and not all of which is.

6 figures
One grey scale, three backgrounds. CIECAM16's lightness against the luminance factor of a neutral sample, with only the background changed. A grey reflecting 19% reads 46.7 on a near-black background and 32.8 on a near-white one. The three curves are not three shapes: each is the same curve raised to a different power, because the background reaches lightness only through the exponent z, which runs 1.621 to 2.374 across the three.

A dark background moves every difference and no match

CIECAM16's background is one number, and it reaches lightness as one exponent. That is enough to change what a grey looks like and not enough to change which of two greys is lighter — so a match survives the background exactly, a corresponding colour is invariant to it, and a tolerance is not. The effect the background is usually invoked to explain is absent from the model entirely.

6 figures
A crispening term puts the peak where the background is. How much lightness the model returns for a small change in the sample's level, against the sample's level measured as a log ratio to the background's — so that all three backgrounds share one axis and a peak at the background is a peak at zero. The pale curves are CIECAM16 as it stands, which has no peak anywhere: they rise slowly and monotonically because a background that enters as four constants fixed before the sample arrives cannot know where the sample sits relative to it. The solid curves are the same model with a term of amplitude 6 and width 0.5 added to lightness. Each peaks at zero to within 0.000 of a log unit, and the peak's height is 12.00 lightness units per log unit of level — the amplitude divided by the width, exactly.

The cancellation is exact and cheap to lose

CIECAM16 has no crispening, and adding one was expected to be expensive: the background's exactness in a corresponding colour comes from its being a common exponent, and a function of the sample's own level is not one. It is expensive in kind and not in size. A term that raises a straddling pair's lightness difference by half moves a corresponding colour by five thousandths of a tristimulus unit — a thousandth of what stating the background differently at the two ends already costs.

7 figures
The pairs that change places in chroma are a wedge with two straight edges. Every pair of samples, plotted by the log ratio of the two samples' background-free responses across and the log ratio of their chroma at a background of 2 up. A pair changes places between that background and one of 80 exactly when its chroma ratio and its response ratio point in opposite directions and the chroma ratio is the smaller — which is the wedge between the horizontal axis and a line of slope -0.2598, half the change in the lightness exponent. 754 of 14028 pairs are inside it, and the condition names every one of them and nothing else: 0 disagreements between the line and the model. The pale dots are one pair in eleven of those outside; the filled ones are every pair inside.

The reversals have a straight edge

Twenty-one of 276 pairs change places in chroma between a dark background and a light one, and the reason given was that chroma is a product of a term carrying the exponent and a term that does not. That is true and it is not a description of which pairs. Chroma at one background is a single common factor times a power of lightness at another, so a pair reverses exactly when its chroma ratio and its lightness ratio point opposite ways and the first is the smaller — a wedge with two straight edges, which names every reversal and nothing else.

7 figures
One lightness scale, drawn as a contour across the rooms. Three surrounds up the page and the background's luminance factor across it, on a square-root scale so that the model's own exponent base is linear in the axis. Each curve joins the rooms whose lightness exponent is the same, and every room on one curve returns the same lightness for every sample. The marked curve is the one through a television in a lit living room against a mid grey: it also passes through a print on a desk against a background of 2.8 and a projection in a dark room against 47.0. A curve that leaves the plot has no member in that surround, because each surround multiplies a base that runs only from 1.48 to 2.48.

Two rooms with one lightness scale

CIECAM16's surround and its background both reach lightness, and they reach it through one product. So the rooms fall into classes: a television in a lit living room against a mid grey returns exactly the lightness a print on a desk against a background of 2.8 does, for every sample, to the last bit of a double. It returns 0.76 of its chroma and 0.81 of its brightness. Two of the model's four viewing-condition parameters are one parameter, and only colour tells them apart.

8 figures