Lens density — where it appears
Named by 5 essays across 2 fields — each of them below, with the objects they name alongside it.
A template cannot place a point
This collection's model of an eye is good to a few tenths of a per cent at predicting what a cone catches, which is far more than enough to place a spectrum. Asked where that eye's confusion points are, it puts the protanope's at (0.99, 0.20) against a measured (0.75, 0.25) and the deuteranope's anywhere from (1.1, −0.5) to (−18, 11) depending on which stimuli the fit was made over.
A trade between matrices, not people
Across the space of possible bases, adapting well and discriminating well pull in opposite directions — the two optima sit at the ends of an empty diagonal. Across a population of actual observers the same two costs move weakly together, at a correlation of +0.29. The trade-off is a property of the set of matrices somebody could choose, not of the eyes anybody has. One measurement inside the population does trade, and it is the macular pigment.
A dimmer session hides a lens band in the rods
A band of extra absorption in an older lens is read by a colour-matching session as lens age or as macular pigment, and it pulls the fitted rod weight with it. The rods see the lens and not the macula, so a dimmer session, where they carry a third of the signal instead of a tenth, was predicted to tell the band from the macula. It does the opposite. With the band at 450 nm left out of the fit, the rod weight's shift grows from 1.7 of its standard errors to 2.5, the misfit a session could notice shrinks by a third, and the macula and the band trade more tightly. The rods see the band — and the rod weight, which the fit is free to move, is exactly what absorbs it. What separates the band from the macula is fitting its amplitude as a fourth number, which works in daylight already.
A second lamp pair finds a lens band's centre
A band of extra absorption in an older lens is found by a colour-matching fit only if the fit has a parameter for it, and a band parameter at a fixed wavelength finds only a band near that wavelength. Freeing the band's centre as a fifth number asks whether the matches can place it. From one daylight-against-LED session they place a band above 430 nm to within six nanometres and one below it only to eight to twelve, where moving the band and ageing the lens change the matches together — and there they barely see the band at all. A second session, the LED against a three-emitter lamp, places every centre within five and a half nanometres. The fluorescent tube's line at 436 nm helps where it sits and nowhere else.
A lost lens band goes to age or the macula
Two colour-matching sessions determine the centre of a band of extra absorption in an older lens to about five nanometres, if a fit can find it. Fitted in full from eight starts across 400 to 470 nm on twenty simulated experiments, two sessions find a band at 415, 430 or 445 nm from every start in fifteen to eighteen experiments of twenty, against eighteen for a fit started at the truth. The prediction was that a low band would be lost from high starts to the macula's flank. The start barely matters with two sessions, and a lost band does go somewhere — but a band at 415 or 430 goes to lens age, three to five years of it, and only a band at 445 goes to the macula. Every loss is a worse fit than the session's best, so eight starts find the band as often as the truth does. With one session the start decides.
Named alongside it
The objects these essays reach for when they reach for this one.
Macular pigmentIdentifiabilityLeast-squaresIndividual variationModelling assumptionStandard errorBasisCone fundamentalsLens yellowingAnisotropyChromatic adaptationCondition number