Concept

Pigment template — where it appears

A formula giving a visual pigment's whole absorbance curve from one number, the wavelength of peak absorbance. It rests on the observation that pigment spectra superimpose when the wavelength axis is scaled by the peak, which holds across species because the absorbing molecule is the same one, and it is what lets a population of differing observers be built at all.

Named by 6 essays across 2 fields — each of them below, with the objects they name alongside it.

How far this site's median observer sits from the 1931 standard, by template. Twenty-four natural reflectances under D65, each given a tristimulus value twice: once by the 1931 colour-matching functions and once by this site's median member, with each judged against its own white. The bar is the mean difference, which is the residual this collection bounds and calls inescapable. It is inescapable, and it is smallest for the simpler template: Lamb's 1995 nomogram gives 0.9006 against Govardovskii's 0.9522, and removing Govardovskii's secondary band brings it down again to 0.9354. Neither is an argument for changing template — a nomogram is fitted to measurements of individual receptors, not to colour matches, so agreement with the standard observer is not what either was trying to achieve. What it says is that the residual is a mismatch between two kinds of observer rather than a shortfall a better pigment model would close. The number after each bar is the template's tail ratio: how far the L cone's half-maximum reaches below its peak against how far it reaches above.

The population rests on a template

Two hundred observers here are built from one formula fitted to microspectrophotometry in 2000. The obvious alternative — the tabulated cone fundamentals — is not available, and the reason is the finding. A tabulated fundamental has no peak wavelength to move, so the moment it is used the population collapses to a single observer.

eye · Cones
A template's asymmetry against what its observer costs. The horizontal axis is the tail ratio of the L cone's pigment absorbance — how far the curve reaches below its peak at half maximum against how far it reaches above — and the vertical is how far the observer built from that template sits from the 1931 standard. A real visual pigment has a long short-wavelength tail, so the three curves derived from a published nomogram sit above 1.1 and the two Gaussians sit below. The four are matched in width, so nothing here is about size. The ordering is the point: the two caricatures cost between two and four times what either nomogram does, and the axis they are separated on is the one feature the caricatures do not have.

A template is mostly its tail

Four pigment templates matched to the same width at the same peak, differing only in which side of the peak their half-maximum reaches further. Ordered by that one number, the observers they build are ordered by how far they sit from the standard one — and the two with the tail on the wrong side cost two and four times what either real nomogram costs.

eye · Cones
The secondary band, dialled from nothing to twice what Govardovskii published. Govardovskii's template has a second, smaller absorption band below 400 nm, published at 0.26 of the α-band's peak. It is the one coefficient in the whole template whose contribution is somewhere else in the spectrum than the peak, and it is the part of the template a reader is least likely to have heard of. Sweeping it from nothing to twice the published value moves the median observer's distance from the 1931 standard from 0.9354 to 0.9790 ΔE₀₀, monotonically upwards. That is a small effect — about a fiftieth of the residual — and its being monotone is the interesting part: there is no interior optimum, so nothing here recommends the published value over any other, and a coefficient whose measured value is not the one that best fits an unrelated agreement is a coefficient to leave where the measurement put it.

The band below four hundred

The pigment template every observer here is built from carries a second, smaller absorption band in the ultraviolet, published at 0.26 of the main one. Dialling it from nothing to twice that moves the median observer monotonically away from the standard one, with no interior optimum — which is what a physical constant looks like when nothing downstream is pulling it anywhere.

eye · Cones
What six of this collection's published numbers do when the unit changes. Six quantities, from six calculations that share nothing: a change of light after an observer has adapted, a camera profile's error, the gap between the two standard observers, a metameric pair under the lamp that breaks it, the same image on two papers, and an observer two seconds into a new room. Each is recomputed under all six units and every unit is calibrated onto ΔE2000's scale first, so the bar is not a change of units in the ordinary sense. The bar is the ratio of the largest reading to the smallest, and it runs from 1.71 to 2.30. Five of the six are printed in ΔE2000 by the essays that report them; the sixth is printed in CAM16-UCS, because the model it comes out of defines that unit.

Three choices reached

Two rounds ago this collection named three things it rested on and could not audit — a unit, a diagonal and a template. All three are now reached, and the interesting part is not the three answers but that four of the round's own predictions were refused by the arithmetic and one of its measurements was wrong in a way only a cross-check caught.

limits · Limits
How far this collection's analytic observer is from the tabulated one. The construction every figure in this family uses is three pigment absorptances through one fitted 3×3, and this is the residual of that fit against the CIE's 1931 functions: root-mean-square error as a percentage of each curve's peak, and the colour difference it produces over forty-two surfaces. The short-wavelength function is the worst at 16.4 per cent, which is where a pigment template is weakest and where the ocular media are doing most of the work. The median colour difference is 1.42 ΔE₀₀, so this is an observer of the right shape rather than a copy of the table — and every departure in this family should be read beside that number rather than against zero.

The reference had to be built

A five-nanometre error cannot be measured with five-nanometre data. Interpolating the tables and integrating finely measures the interpolator, not the grid — so the audit of this collection's index had to be run against an observer made of formulae, and the price of that is a residual of 1.42 ΔE₀₀ that every number in the section is read beside.

limits · Limits
The three cone absorptances at two settings of the pigment peaks. Solid and dashed are the same construction at the two ends of two standard deviations, and the L/M polymorphism on top. The curves are built from one pigment template through its ocular media, which is the same model its population of two hundred eyes is drawn from. The largest difference between the two sets is 8.9 per cent of the peak, and where it sits along the wavelength axis is what decides which stimuli the two observers disagree about — a departure concentrated in the blue is invisible on a sample with no blue in it.

The peaks move the flanks

Shifting a cone's peak wavelength by three nanometres changes its sensitivity at its own maximum by almost nothing and on its flanks by several per cent, because a maximum is flat and a flank is steep. Every display primary sits on a flank, which is why a pigment polymorphism is worth 3.60 ΔE₀₀ under a laser projector.

eye · Cones

Named alongside it

The objects these essays reach for when they reach for this one.

Standard observerSensitivityColour-matching functionsLambda maxNomogramCone fundamentalsMacular pigmentSelf-screeningAssertionAsymmetryAuditBandwidth

All concepts