Signal-to-noise — where it appears
Named by 5 essays across one field — each of them below, with the objects they name alongside it.
Correcting colour costs noise
The matrix that turns a sensor's raw into XYZ has large off-diagonal terms of both signs, because that is what correcting a sensor which fails Luther's condition requires. Differences of large numbers are where noise grows, and the full correction amplifies photon noise by 1.66 times.
Clipped noise does not average away
Noise on a raw reading is as likely to fall below the true value as above it, which is why averaging an area removes it. A converter that sets negative readings to zero keeps the upper half and throws the lower away, and the mean of what is left is the signal plus a pedestal. With no black level error anywhere, a half per cent grey under a tungsten lamp comes out 1.04 colour differences off at high gain, 8.98 after a four-stop push — and a blur that removes every trace of the noise leaves the tint where it was.
The converter can choose except where it matters
A converter rebuilding a clipped highlight has to say whether the surface was matt and over-exposed or glossy and carrying a reflection, and the evidence is whether its raw chromaticity slides towards the lamp's on the way up. Read through the sensor's own noise, the slide is clear on most of the chart from the few tens of pixels a specular highlight holds — and on the surfaces where it takes half a frame, confusing the two models costs more than the median. A ratio cannot see a common scale, and an exposure supplies one.
Four places to clamp are two pipelines
The essay on clipped noise ended on a procedure: a black frame and a dim grey card at a high amplification would place each raw converter's clamp. A procedure is a claim that a measurement identifies something, and this one identifies less than it looks. A clamp at zero commutes with the white balance and with the tone curve and not with the colour matrix, so the four positions are two pipelines — and the measurement separates them, on a card at half a per cent of white rather than on the black frame.
Two lamps decide what one lamp could not
Under one lamp a handful of surfaces cannot tell a glossy highlight from a matt over-exposure without most of a frame, because there the two differ by a scale a ratio cannot see. In a room lit evenly by a 3000 K lamp and daylight, every surface on the chart is decided from ten pixels. A body can sit at one lamp's white, not at two, and the rescue holds only while the second lamp carries a fifth of the light and its white sits far enough from the first.
Named alongside it
The objects these essays reach for when they reach for this one.
Camera rawNoiseClippingIdentifiabilityShot noiseWhite balanceCamera sensorColour matrixDichromatic reflectionHighlight recoverySpecularDeclared input