Colour matrix — where it appears
Named by 22 essays across 2 fields — each of them below, with the objects they name alongside it.
Raw is not a picture
A raw file is three integrals per site and a list of decisions nobody has taken yet. Every one of those decisions has a defensible answer and none of them has a correct one, which is why two converters open the same file and disagree.
Luther said when it would work
There is an exact condition under which a fixed three-by-three matrix converts camera raw to XYZ correctly for every spectrum in existence. It was stated in 1927, it is a theorem rather than a guideline, and no camera ever built satisfies it.
A camera profile is a fit
Since no matrix is exact, the one a manufacturer ships is a least-squares compromise over a set of surfaces somebody chose. Fitted on desaturated patches it is excellent on desaturated patches — and the sample set is a hidden argument to every camera profile in existence.
No matrix is right everywhere
The best three-by-three this sensor admits, fitted and tested on the same twenty-four surfaces, leaves a worst case of ΔE00 2.85. A control sensor built to satisfy Luther's condition reaches ten to the minus seven under the identical computation, which is what makes the first number a measurement.
Correcting colour costs noise
The matrix that turns a sensor's raw into XYZ has large off-diagonal terms of both signs, because that is what correcting a sensor which fails Luther's condition requires. Differences of large numbers are where noise grows, and the full correction amplifies photon noise by 1.66 times.
A photograph is not a measurement
A photograph is a measurement made by an instrument whose kernel nobody published, under an illuminant nobody recorded, corrected by a matrix fitted to somebody else's surfaces, with two thirds of every pixel invented. It supports relative claims well and absolute ones badly, and it is used for the second.
Fitted to an eye nobody has
A camera profile's residual against the observer it was fitted to is under a unit, and that is the number everybody quotes. Against a person drawn from a population it is 3.35 at the ninety-fifth percentile — and a camera with no spectral error whatever, reporting the standard observer's tristimulus values exactly, would carry 3.47. The camera is not the problem.
A camera balances in another basis
White balance is a per-channel gain on raw values, which makes it a von Kries adaptation in whatever axes the filter dyes happen to give. Those axes are not a property of the dyes alone — they move with the light, by up to seventeen degrees across the adaptation census — and the sensor for which they would not move is the one that adapts worst of all.
A tolerance cannot cross a condition
If two measurement conditions disagree by seven units, the obvious repair is a correction matrix fitted between them. The best least-squares 3×3 over seventeen printed patches leaves 23 per cent of the disagreement and makes five patches worse than doing nothing — because the term it is trying to remove is proportional to how much paper is showing, and no linear map on three numbers can express that.
A camera cannot record the excitation
Two lamps of nearly the same chromaticity, one with ultraviolet and one with none, put a brightened sheet twelve units apart after a perfect white balance. Nothing in the camera measured the difference — the filter stack removed the band before the sensor saw it — so the correction that would fix the picture needs a quantity the file does not contain.
The chart decides the profile
A camera's colour matrix is nine numbers fitted to a set of patches somebody chose, and the number that comes with it is the error on those patches. On a chart with no chromatic range that number is 0.19 ΔE00 and the matrix delivers 1.65 — and a second matrix, indistinguishable on the chart, delivers 2.03.
A matrix is fitted under one light
A camera's colour matrix is nine numbers determined by a chart photographed under a particular illuminant, and the error it quotes is the error under that illuminant. Fitted under a tungsten lamp and used under a cold sky it delivers eight times as much — and the two-matrix scheme every real profile uses turns out not to be a compromise at all.
The chart was measured by an observer too
A camera profile is fitted so that the camera's numbers reproduce the chart's measured tristimulus values. Those values were computed through the 1931 observer, so the fit inherits every departure in this round — and the fit's own residual, at 0.19 ΔE₀₀ on the chart, is fifteen times smaller than the term it cannot see.
The corner of the frame has another filter
A camera's infrared-cut filter is an interference stack, and light crossing it at an angle sees its edge moved towards the blue — from 665 nm at the centre of a frame to 646 at twenty-five degrees. The corner's red channel loses a tenth of its response under daylight and a sixth under tungsten. A grey-card gain map makes the corner exactly right under the lamp it was made under; under a tungsten lamp the same grey is 2.6 colour differences wrong, under a white LED 4.2, and even under its own lamp the coloured patches are not corrected, because a moved edge is not a gain.
A black level is multiplied by the balance
Every raw value carries a pedestal that is subtracted before anything else, and a white balance is then a different gain in each channel. Subtracting a constant and multiplying by one commute only when the constant is zero or the gains are equal. So a pedestal left three thousandths of white too high becomes 2.4 colour differences in a two per cent grey, most of it chroma, in the colour the lamp starves — and pushing that shadow four stops in editing makes it 8.9. An offset in proportion to the lamp's own white is the exception, and it is exactly grey.
A corner is corrected by one row
A grey-card gain map makes the corner of a frame exactly right on grey and leaves coloured patches 1.86 colour differences wrong at twenty-five degrees. A three-by-three matrix fitted at that position halves it — and six of its nine numbers do nothing, because the moved filter edge is in one channel. The three that matter rebuild the lost red from green and blue, they carry to another lamp better than a gain map in eleven cases of twelve, and in the twelfth, a row fitted under tungsten and used in daylight, they leave the grey 9.2 off.
Two matrices do not reach a white LED
A camera profile's two matrices, blended by the scene's colour temperature, are as good as a matrix fitted anywhere along daylight. Under a white LED or a fluorescent tube the same blend leaves colours twice as far off as a matrix fitted under that lamp, and no weight inside the profile's range repairs it. What decides it is not how far the lamp sits from the Planckian locus — a triphosphor tube sits nearly on it and fares worst — but whether its spectrum has lines in it, which a white balance reading cannot see.
Flicker sorts lamps the wrong way
A camera cannot see a spectral line in its own white, so the essay on the two-matrix profile named the classifiers a device might have instead, and the first of them was flicker. Flicker is measurable, and it measures the wrong thing. It sorts lamps by how their power is delivered while the matrix needs them sorted by how their spectrum is shaped, and the two are independent: a white LED on a constant driver is perfectly steady and strongly structured, and it is what most indoor photographs are lit by.
Four places to clamp are two pipelines
The essay on clipped noise ended on a procedure: a black frame and a dim grey card at a high amplification would place each raw converter's clamp. A procedure is a claim that a measurement identifies something, and this one identifies less than it looks. A clamp at zero commutes with the white balance and with the tone curve and not with the colour matrix, so the four positions are two pipelines — and the measurement separates them, on a card at half a per cent of white rather than on the black frame.
Two sensors disagree about deep red, not lines
A phone's ambient-light sensor and its camera read the same lamp differently, and the difference sorts fourteen lamps into smooth and structured without a single mistake — where flicker made five. It is not reading their lines. Almost all of it comes from the sensor's clear channel collecting deep red the camera's infrared cut throws away, so daylight with its far red trimmed is called structured and a white LED with a far-red emitter is called smooth.
A narrow channel has to be read on its own
An ambient sensor with a clear channel tells structured lamps from smooth ones by reading deep red, and one without it reads structure but breaks at one per cent of calibration error. A narrow fourth channel between the camera's peaks was proposed to have both. Pooled into the sensor's disagreement with the camera, it reads structure and breaks at one and a quarter per cent — no better than the design it was meant to rescue. Read on its own, as its departure from what the camera predicts for it, a channel at 450 nm holds to four per cent, the clear channel's figure, and far red does not move it.
One row for every lamp costs the lamps that lose least
A corner correction fitted under one lamp is right under that lamp and can be badly wrong under another, so a converter unsure of its lamp was offered a single row fitted under several at once. Pooled over four lamps, one row holds every lamp's corner between 1.33 and 1.56 colour differences — no lamp worse than a grey-card map, and none near the 4.91 a wrong row can leave. The price falls on the white LED and the fluorescent tube, which it leaves four times worse than their own rows, because they lose the least red at the corner and the pooled row is built to repair the lamps that lose the most. Two rows, one per class of lamp, keep almost all of both.
Named alongside it
The objects these essays reach for when they reach for this one.
Camera rawSpectral sensitivityWhite balanceCalibrationLeast-squaresLuther conditionIdentifiabilityIlluminantHeld-out validationInfraredLED emissionCamera profile