The thread: The instrument is the reader — page 7
A model is a claim about what can be known
The exact answer to chromatic adaptation is nine numbers, and the nine numbers are the change of light itself. A model whose parameters are quantities the observer cannot obtain is not a worse model of the same thing — it is a model of something else, and counting parameters without asking where they come from hides the difference.
The population rests on a template
Two hundred observers here are built from one formula fitted to microspectrophotometry in 2000. The obvious alternative — the tabulated cone fundamentals — is not available, and the reason is the finding. A tabulated fundamental has no peak wavelength to move, so the moment it is used the population collapses to a single observer.
A template is mostly its tail
Four pigment templates matched to the same width at the same peak, differing only in which side of the peak their half-maximum reaches further. Ordered by that one number, the observers they build are ordered by how far they sit from the standard one — and the two with the tail on the wrong side cost two and four times what either real nomogram costs.
A dial has a price
Two rounds declined to give the appearance model's surround a continuous control, both times because the frames would be too heavy, and neither time was the weight taken. It is 2.25 kilobytes at the median — the light end of these figures rather than the heavy end — and one figure is already breaking the rule the deferral was made under.
Three choices reached
Two rounds ago this collection named three things it rested on and could not audit — a unit, a diagonal and a template. All three are now reached, and the interesting part is not the three answers but that four of the round's own predictions were refused by the arithmetic and one of its measurements was wrong in a way only a cross-check caught.
The model has six arguments
Every colour computed here is an integral of a reflectance against a light against three curves, and a reflectance is one number per wavelength. A real surface's response is a function of six arguments — the wavelength, direction and place light arrives with, and the three it leaves with — so the model keeps one of them, takes a diagonal, integrates two away and assumes two more equal.
Either factor being zero
Four different departures from the colour integral turn out to have one algebraic form — each is an inner product of something the sample does that the model has no slot for with something the light does that the model assumed away. Either factor being zero makes the departure exactly zero, and the sizes of the two factors decide neither how large it is nor which way it goes.
A surface has a kernel
Light that enters a translucent material does not come back where it went in. It scatters some thousands of times and leaves a few millimetres away, so what the surface has is not a reflectance but a function of distance — and the reflectance the model wants is that function's integral over the whole plane, which no instrument ever collects.
An aperture is a filter
A measuring aperture throws away the light that came back outside it, and the light that comes back furthest is the light at the wavelengths the sample absorbs least. So an aperture does not attenuate a translucent sample evenly — it attenuates its peaks more than its troughs, which is a filter whose transmission curve the sample itself decides.
The hue the hole decides
A piece of pale marble measured through a wide aperture is faintly yellow. Measured through a narrow one it is faintly blue, and between the two there is an aperture at which it is exactly neutral. Nothing about the stone changes; the aperture is a filter with a colour, and what decides that colour is the size of the particles rather than the pigment between them.
A room is not a sphere
An integrating sphere reads a surface's own reflectance exactly, and the exactness is a theorem rather than good engineering — under a hemisphere of constant radiance, reciprocity makes the reading the sample's directional-hemispherical reflectance whatever the surface is. Every room fails that condition, and a viewing booth and a window get the sign of the error wrong in opposite directions.
Either disc can be the wide one
Every standard on translucent samples says to illuminate a larger area than is measured, and explains it by saying that light leaks out of the lit spot. That is true and it is not the reason, because the instruction works equally well the other way round — measuring a larger area than is lit gives a reading just as exact. The error is a product of two apertures and either one being wide kills it.
A mixture in the variable nobody named
Kubelka–Munk works because absorption and scattering add over a mixture and reflectance does not. What adds is the absorption of the pigment layer, and what an instrument reports is that layer seen through an interface — related by a Möbius function rather than by a constant. Mixing in the reported variable instead of the internal one costs between three and eight ΔE₀₀, and no source this collection quotes says which variable its curves are in.
Which index to buy an instrument for
Four departures from the colour integral, ranked by what they cost and by what it would take to remove each one. The ranking by cost and the ranking by price are almost exactly reversed — the two largest are removed by specifying a lamp and by widening a table, and the two that need new hardware are the two smallest.
The ultraviolet is half the product
A fluorescent sample's departure from the reflectance model is exactly proportional to the ultraviolet the lamp carries — to twelve figures, over a range that includes zero. It is the only one of the round's four departures that really is a product of two magnitudes, and the reason is a rule about how molecules relax rather than anything about arithmetic.
The grid is a range, not an index
Three of the four departures in this round restore an argument the model dropped. The fourth does not — the 380-to-780-nanometre grid is the range of the one argument the model kept, chosen in the first weeks and never revisited. It costs 6.70 ΔE₀₀ on a coated printing paper, it is the cheapest of the four to fix, and it is the one still unfixed.
A pixel has an aperture too
A camera photographing a translucent object has the same two discs a spectrophotometer has — one lit, one looked at — and gets them the other way round. Its illumination covers the whole scene, so the flat colour of a translucent surface comes out exactly right at any magnification, and the error moves entirely into the edges.
Two departures that partly cancel
A glossy translucent sample has two of this round's four departures at once, and the expectation was that they would compound. They do the opposite. An aperture takes light away that went into the material and came back too far out; an interface returns light that never went in at all — so measuring either alone overstates what both together do, on every material tested.
A pair the aperture separates
Two constructed slabs with the same reflectance at every wavelength, to fifteen figures — the same colour to any observer under any light — and 6.25 ΔE₀₀ apart when measured through a four-millimetre aperture. It is a metamerism with no observer in it, no illuminant in it, and no spectral difference to construct it from.
Two blurs before the eye's own
A translucent object arrives at the eye already blurred, by a kernel that is a property of the material rather than of the optics. On every material in this collection's table that blur is coarser at ordinary reading distance than the finest detail the eye can resolve — so the softness of marble or skin or wax is not a failure of vision, it is the object.
The appearance model has no slot for it
Two slabs with identical reflectance and different kernels come out of CIECAM16 with identical lightness, chroma and hue — to six decimal places, because the model's input is a stimulus and their stimuli are the same. Translucency is a recognised appearance attribute with no correlate in any appearance model, and the reason is structural rather than an oversight.
The chart was measured, not photographed
A camera profile is fitted so that the camera's response maps onto the chart's tristimulus values, and those values came out of a spectrophotometer. So the profile's target carries the instrument's departures and the camera does not — a mildly translucent chart read through a four-millimetre aperture supplies targets 2.55 ΔE₀₀ from the truth, which is twice the profile's own fitting error.
The departures are larger than the tolerance
A delivery tolerance is written around one ΔE₀₀ and every one of this round's four departures is above it on ordinary material. A specification that names an illuminant, an observer and a tolerance, and does not name a measurement condition, an aperture and a field, has written a number that two honest laboratories can miss each other on by more than the number itself.
A departure is not a unit
The previous round audited six published quantities by swapping the unit they were quoted in — a function applied at the end of each computation. Nothing of that shape works here. A departure changes the object at the start, so every stage in between has to accept it, and only two of the same six quantities can take one at all. The fourth cannot even be expressed in the interface.
258 essays on this thread, page 7 of 11 · all threads · all essays