Theme

The thread: Three numbers — page 5

An infinite-dimensional spectrum is projected onto three cone responses, and everything colour science can do — and every way it fails — follows from that single collapse.
The collection's adaptation census, with its surfaces departed. Each row is one of the fourteen changes of light in this site's adaptation census, and the bar is what a von Kries gain leaves behind. The open marks are the published numbers; the filled ones are the same computation with every one of the hundred and twenty-five test surfaces replaced by what an instrument with an aperture, or a room with a direction in it, actually reports. Nothing moves by more than 9 per cent. A departure that does not depend on the light is very largely absorbed by the observer's own gain, because it changes the reflectance and the gain is applied afterwards. The fourth departure is not on this chart and cannot be: a fluorescent sample has a different curve under every light, so there is no set of reflectances to hand the census at all. What a camera does

The chart was measured, not photographed

A camera profile is fitted so that the camera's response maps onto the chart's tristimulus values, and those values came out of a spectrophotometer. So the profile's target carries the instrument's departures and the camera does not — a mildly translucent chart read through a four-millimetre aperture supplies targets 2.55 ΔE₀₀ from the truth, which is twice the profile's own fitting error.

a fluorescent tube, mercury lines on a phosphor bed, with a 5-nanometre grid marked on it. The light drawn at a fifth of a nanometre, with the 5-nanometre tabulation points marked beneath. 38 of the 53 points carry more than a twentieth of the peak. What a summation over those points computes is not an approximation to the area under this curve; on a spectrum with features narrower than the spacing it is a different quantity, and the difference depends on where the points fall rather than on how many there are. What light is

The index is a choice too

Every colour in this collection is a sum over eighty-one numbers running from 380 to 780 nanometres in steps of five. That index is not a property of the eye, the light or the sample — it is a tabulation, and it holds three separable decisions that behave completely differently from one another.

What three fill-in rules cost when a five-nanometre table is read at one. A five-nanometre table read at one nanometre by three rules — hold the value, straight lines, a cubic through four points — each compared with the same tenth-nanometre reference. The dashed rule is the answer obtained by summing the table as it stands, at 0.00000 ΔE₀₀. Two of the three interpolations are worse than not interpolating. That is not a paradox: the summation's error is already small because the normaliser cancels most of it, and an interpolator introduces a shape the original curve did not have, which the cancellation cannot touch. A finer grid is not more resolution when the table is not finer. What light is

A finer reading of a coarser table

Interpolating a five-nanometre spectrum to one nanometre helps a daylight calculation by a factor of five and harms a three-emitter LED by a factor of a hundred and twenty thousand. Both are the same operation on the same table, and which one happens is decided by a property of the light nobody records.

The two tabulation choices over forty-two surfaces, under a tungsten lamp at 2856 K. Each column is one choice, measured over a family of forty-two analytic reflectances rather than on a single example: an absorption band of stated centre, width and depth. The four marks are the smallest, the median, the ninety-fifth percentile and the largest cost in ΔE₀₀, logarithmically. Under a smooth light the range is worth 6.3 times the step at the median, so a collection wanting one repair should widen its range rather than refine its step — and under a fluorescent tube the ranking reverses outright. Difference and uniformity

A neutral has no grid

A perfectly flat reflectance computes to exactly the same colour on every wavelength grid, through every slit, at every origin, and for every observer — not nearly, but to the last bit of a floating-point number. The condition is an identity rather than a limit, and what makes it one is the white point.

What each end of the 380–780 nanometre range costs, by light. Two bars per light, on a logarithmic axis: the upper is what extending the range down to 300 nanometres moves the answer, the lower what extending it up to 830 does. The asymmetry is the whole figure. A thermal source has about a fifth of its power outside this collection's range and almost all of it at the long end, where the observer is already zero; what costs money is the short end, where the observer is small but not zero and daylight is still strong. A light with no ultraviolet — an LED lamp, a laser — pays nothing at either end, which is the pairing again: a range only costs what the light puts in it. What light is

Two ends and one is empty

Extending this collection's wavelength range down to 300 nanometres moves a red pigment under daylight by 0.502 ΔE₀₀. Extending it up to 830 moves the same colour by 0.00015. A fifth of a thermal source's power lies outside the range and almost none of its colour does, and confusing those two shares is how a range gets argued about instead of measured.

The two tabulation choices over forty-two surfaces, under a 6500 K thermal radiator. Each column is one choice, measured over a family of forty-two analytic reflectances rather than on a single example: an absorption band of stated centre, width and depth. The four marks are the smallest, the median, the ninety-fifth percentile and the largest cost in ΔE₀₀, logarithmically. Under a smooth light the range is worth 9.1 times the step at the median, so a collection wanting one repair should widen its range rather than refine its step — and under a fluorescent tube the ranking reverses outright. What light is

Which end to buy

Refining a five-nanometre grid to one buys a daylight calculation 0.05 ΔE₀₀ and widening its range buys 0.54. Under a fluorescent tube the same two purchases are worth 0.83 and 0.0001. The ranking reverses completely, and what decides it is one length compared against one other length.

What the normaliser cancels, per light. Two bars per light, logarithmic. The upper is the colour error a 5-nanometre sum makes when the white it is divided by is computed finely; the lower is the same sum divided by the white computed on the same coarse grid, which is what every colorimetric calculation actually does. The ratio is between 1.3 and 4.1. The grid appears twice in a tristimulus value and the two errors are the same error, so most of it divides out — which is why five nanometres has been good enough for a century without anybody having to be careful about it. Difference and uniformity

The normaliser carries the error too

A five-nanometre sum gets a red pigment's tristimulus value wrong by two hundredths of a per cent and its colour wrong by six hundredths of a unit. Those two numbers are not the same size because the grid appears twice in a colour — once in the sample and once in the white — and the two errors are largely the same error.

What a tabulation step costs, by light, on paper. The horizontal axis is the tabulation step in nanometres, from one to twenty; the vertical is how far the resulting colour is from the same integral taken at a tenth of a nanometre over the same range, in ΔE₀₀, on a logarithmic scale. Each line is one light. The three with no feature narrower than the step fall smoothly and stay below a tenth of a unit at five nanometres, which is the grid used throughout. The fluorescent tube and the laser projector do not fall at all: their lines are narrower than any step drawn here, so the answer depends on where the samples land rather than on how many there are. The sample is held at paper throughout. What light is

A grid is not a resolution

Ten essays into this collection there is one sentence about wavelength sampling, and it is that five nanometres is enough. Ten measurements later there are three decisions, three mechanisms, three repairs and two rankings, and the word resolution names none of them.

The arguments a standard observer does not have. Seven choices inside a set of colour-matching functions, each with the shape it takes and what it is worth in ΔE₀₀ on a red pigment under a 6500 K radiator. Six are measurements: a field size, an age, a macular density, a cone optical density, three peak wavelengths and a rod contribution. The seventh is not — a change of basis is a change of curves and not a change of observer, and its entry is exactly zero because the space an experiment measures is what an observer is. Printing that zero beside the others is the clearest statement of what the other six are measurements of. What the eye does

The third factor is a construction

Every figure in this collection names its observer, which was the whole point. None of them says what an observer is made of. Three curves are not a measurement of the eye; they are a projection of one, with a field size, an age, a macular density, three peak wavelengths and a luminance constraint inside them.

The conditions under which an observer's departure is exactly zero. A departure of the observer is the pairing of something belonging to the observer with something belonging to the stimulus, so emptying either factor empties the product. The axis is logarithmic in what is left when the condition is imposed. Six rows empty the stimulus's factor — a perfectly neutral sample is the same colour for every observer, at any age and any field size — and two empty the observer's, since a gain on each cone and a change of basis are both absorbed exactly. All eight are identities rather than small numbers. The last two are the same two conditions imposed in a published cone space rather than in the observer's own, and they are worth eight and thirteen units: the identity is about the eye, and the arithmetic everybody uses is in somebody else's coordinates. What the eye does

A neutral is everyone's colour

Two eyes differing by fifty years of lens yellowing, by a factor of three in macular pigment and by six nanometres of long-wavelength peak agree about a grey card to four parts in ten thousand billion. The agreement is an identity rather than a coincidence, and it says exactly what an observer disagreement is a disagreement about.

The arguments a standard observer does not have. Seven choices inside a set of colour-matching functions, each with the shape it takes and what it is worth in ΔE₀₀ on a red pigment under a 6500 K radiator. Six are measurements: a field size, an age, a macular density, a cone optical density, three peak wavelengths and a rod contribution. The seventh is not — a change of basis is a change of curves and not a change of observer, and its entry is exactly zero because the space an experiment measures is what an observer is. Printing that zero beside the others is the clearest statement of what the other six are measurements of. What the eye does

Three curves for one space

Rotate a set of colour-matching functions by an arbitrary invertible matrix, undo the rotation at the end, and the computed colour is identical to eight parts in a thousand million million. An observer is a three-dimensional subspace, not a set of curves, and the literature keeps reopening a question that is a theorem.

Every departure under every light. Six departures across six lights, each cell the difference between two observers in ΔE₀₀, drawn as a bar whose length is the number. The rows are not multiples of one another: the lens is worst under tungsten and the pigment peaks are worst under a three-emitter LED, because a departure is a pairing and which light is being paired with decides it. The laser projector's row is empty, and that is not a fact about lasers — on this collection's five-nanometre grid a three-line spectrum is a one-line spectrum, and a single wavelength is a stimulus every observer agrees about exactly. What the eye does

The lens is worst under tungsten

An ageing lens costs 4.38 ΔE₀₀ under a tungsten lamp and 2.20 under a fluorescent tube. The pigment peaks cost 2.84 under a three-emitter LED and 1.87 under the same tube. Six departures across six lights do not form a single ordering, which is what a pairing looks like and what a dominant term would not.

A departure against how far the sample sits from the light. The sample is mixed with a flat reflectance, from the flat one at the left to its own at the right, and two observers differing in the macular pigment look at each mixture. The straight line is the distance between their relative cone excitations, and it is straight to 0.0 per cent: the departure is a pairing, and scaling one factor scales the product. The curved line is the same sequence in ΔE₀₀, which is not a linear function of the excitations and cannot be — it has cube roots in it and a chroma weighting underneath. The identity is about the eye; the curvature belongs to the unit. Difference and uniformity

A departure is straight in the excitations

Walk a sample a quarter of the way from the light towards its own reflectance and exactly a quarter of the observer disagreement remains — in cone excitations, to two parts in a hundred. In ΔE₀₀ the same quarter leaves 0.347 where proportionality wants 0.428, and the discrepancy belongs entirely to the unit.

Each departure over forty-two surfaces rather than one. The same six departures measured over a family of forty-two analytic reflectances — an absorption band of stated centre, width and depth — with the smallest, the median, the ninety-fifth percentile and the largest marked. Every one of them spans more than a factor of three, and the ranking between them is not stable across the family: what decides a departure's size is which sample it is asked about, because a departure is a pairing and the sample is one of the two factors. Quoting any single number for what an observer's age is worth is quoting a choice of example. What the eye does

The ranking is not stable

On a red pigment under daylight the six observer departures run from 2.38 down to 1.20 ΔE₀₀. Over forty-two surfaces two of them change places, the top two separate, and every one spans between a factor of ten and a factor of thirty-five. A chart of six bars is a chart of one example.

The three cone absorptances at two settings of the field size. Solid and dashed are the same construction at the two ends of the CIE's own second observer. The curves are built from one pigment template through its ocular media, which is the same model its population of two hundred eyes is drawn from. The largest difference between the two sets is 16.0 per cent of the peak, and where it sits along the wavelength axis is what decides which stimuli the two observers disagree about — a departure concentrated in the blue is invisible on a sample with no blue in it. What the eye does

A field size is two changes

The CIE publishes two standard observers and the difference between them is usually described as a field size. What actually differs is a macular pigment the light no longer passes through and a cone outer segment the light no longer travels the length of — two changes, in two places, with different signs and different sample dependence.

The three cone absorptances at two settings of the rods. Solid and dashed are the same construction at the two ends of a tenth of the cone response, which is a dim room. The curves are built from one pigment template through its ocular media, which is the same model its population of two hundred eyes is drawn from. The largest difference between the two sets is 9.1 per cent of the peak, and where it sits along the wavelength axis is what decides which stimuli the two observers disagree about — a departure concentrated in the blue is invisible on a sample with no blue in it. What the eye does

The rods are a fourth curve

Colorimetry has three numbers and a rod signal is a fourth. It cannot be absorbed by a gain, it cannot be removed by a white point, and adding a tenth of one to a three-curve observer costs 1.60 ΔE₀₀ — the narrowest distribution of the six departures, because an addition behaves quite differently from a filter.

The three cone absorptances at two settings of the macular pigment. Solid and dashed are the same construction at the two ends of two standard deviations of the reported spread. The curves are built from one pigment template through its ocular media, which is the same model its population of two hundred eyes is drawn from. The largest difference between the two sets is 31.5 per cent of the peak, and where it sits along the wavelength axis is what decides which stimuli the two observers disagree about — a departure concentrated in the blue is invisible on a sample with no blue in it. What the eye does

The macular is a band, not a filter

The lens absorbs everything below 500 nanometres with a long tail; the macular pigment absorbs forty nanometres either side of 460 and nothing else. The two have similar sizes and completely different distributions, and the reason is that one is broad and one is narrow — which is what decides whether a sample is affected at all.

The three cone absorptances at two settings of the pigment peaks. Solid and dashed are the same construction at the two ends of two standard deviations, and the L/M polymorphism on top. The curves are built from one pigment template through its ocular media, which is the same model its population of two hundred eyes is drawn from. The largest difference between the two sets is 8.9 per cent of the peak, and where it sits along the wavelength axis is what decides which stimuli the two observers disagree about — a departure concentrated in the blue is invisible on a sample with no blue in it. What the eye does

The peaks move the flanks

Shifting a cone's peak wavelength by three nanometres changes its sensitivity at its own maximum by almost nothing and on its flanks by several per cent, because a maximum is flat and a flank is steep. Every display primary sits on a flank, which is why a pigment polymorphism is worth 3.60 ΔE₀₀ under a laser projector.

What the floor receives, matt walls against walls of roughness 0.2. The spectral radiance leaving the floor towards the front of the room, computed twice. The matt curve peaks at 530 nanometres, where the walls' pigment is. The glossy curve is higher everywhere and higher by relatively more away from that peak, because the extra light is a Fresnel return and a Fresnel return has the lamp's spectrum rather than the paint's. That difference in shape is the desaturation, drawn before it is reduced to a number, and it is the reason the two lines cannot be brought together by any exposure change. What a scene does

A lobe takes colour out of a bounce

A gloss wall sends more light to the floor and less colour. The extra light is a Fresnel reflection at the interface, it carries the lamp's spectrum rather than the paint's, and it arrives at the next surface white — so a green room in satin paint is less green than the same room in flat paint by nearly a colour difference of chroma.

The lobe's share of what leaves a surface of body reflectance 0.5. For light arriving at 45°, the fraction of what leaves the surface that is the interface's Fresnel return rather than the pigment's. It runs from about 9.1 per cent at an eggshell finish down to 4.2 at a matt one. That is a small share, and it is the whole of the effect: a tenth of the return arriving white is enough to move the room's colour by units of ΔE₀₀, because the bounce is what a room's colour is made of and every bounce is multiplied by the next. What a scene does

A tenth of the return arriving white

Nine per cent of what leaves a satin wall is a Fresnel reflection carrying no pigment. That nine per cent moves the room's colour by 4.89 ΔE₀₀ and its chroma by five per cent, because an interreflection multiplies and a small contribution with a different spectrum compounds into a large one.

The two tabulation choices over forty-two surfaces, under a 6500 K thermal radiator. Each column is one choice, measured over a family of forty-two analytic reflectances rather than on a single example: an absorption band of stated centre, width and depth. The four marks are the smallest, the median, the ninety-fifth percentile and the largest cost in ΔE₀₀, logarithmically. Under a smooth light the range is worth 9.1 times the step at the median, so a collection wanting one repair should widen its range rather than refine its step — and under a fluorescent tube the ranking reverses outright. What the brain does

The grid under the census

The adaptation census is computed on eighty-one wavelengths from 380 to 780 nanometres. Under the daylight and blackbody sources it uses, the range is worth about half a colour difference on ordinary surfaces and the step about a twentieth — so the census carries a tabulation term as well as an observer one, and they are not the same size.

The share of each light outside 380–780 nanometres, as power and as visual product. Two measurements of the same truncation. The upper bar is the fraction of the light's radiant power that lies outside the range; the lower is the fraction of the product of light, sample and observer — which is what a colour is made of. A thermal radiator puts a fifth of its power outside and about a thousandth of its colour, because the observer is zero where most of that power is. The gap between the two bars is the observer's own tails doing their job, and reading the upper number as though it were the lower is how a range gets argued about without being measured. What light is

A lamp is two audits at once

A lamp's ultraviolet content decides what its tabulation costs and its blue content decides what its observer costs, and the two run in opposite directions with colour temperature. So no lamp is good for both audits and no lamp is bad for both, and a single figure of merit for either is a figure of merit for one property of a spectrum.

The arguments a standard observer does not have. Seven choices inside a set of colour-matching functions, each with the shape it takes and what it is worth in ΔE₀₀ on a red pigment under a 6500 K radiator. Six are measurements: a field size, an age, a macular density, a cone optical density, three peak wavelengths and a rod contribution. The seventh is not — a change of basis is a change of curves and not a change of observer, and its entry is exactly zero because the space an experiment measures is what an observer is. Printing that zero beside the others is the clearest statement of what the other six are measurements of. What a camera does

A sensor has no lens

A camera is a fourth observer and it is the only one with none of the six arguments this round measured. It does not age, it has no macular pigment, its response does not broaden with density and its peaks do not vary — so it is perfectly reproducible and is not any of the observers it is fitted to reproduce.

One surface dimmed sixteen times, and the two things that happen to it. A single surface, dimmed by successive halvings, with the lens age departure measured on it at every level. The tristimulus deviation falls by exactly the dimming factor — 16 times over the sweep, to the last bit, because the colour integral is linear in the stimulus. What a unit of that deviation is worth rises by 8.2 times over the same sweep. The colour difference the audit reports is the product of the two, and it falls by only 1.95. Matching and measuring

A deviation is not a difference

The previous round priced twenty departures in colour differences and treated each number as a property of the thing that departed. Every one of them is a product of two factors — how far the reading moved, which is linear and belongs to the departure, and what a unit of that movement is worth where it landed, which is not linear and belongs to the colour. Dimming one surface sixteen times scales the first by exactly sixteen and the second by eight.

207 essays on this thread, page 5 of 9 · all threads · all essays